RI2A – Insulation monitor (4 Modul)


  • Iso D4 insulation monitor for continuous control of insulation towards earth
  • Suitable for IT systems with 24…400 VAC
  • Selectable alarm threshold from 20…200 kΩ
  • 6-position threshold setting by rotary switch
  • Alarm indication via red LED and relay output
  • Automatic reset and manual test for function checking
  • 1 SPDT changeover contact with 5 A / 250 VAC contact rating
  • 4-DIN-module housing for DIN rail, screw or optional flush mounting
Datasheet

Iso D4

Insulation monitor for IT distribution systems, 4 DIN modules

Type Insulation monitor for continuous control of insulation towards earth
Model Iso D4
Format 4 DIN modules according to DIN 43880
Network type IT distribution system
Network voltage 24…400 VAC
Alarm threshold 20…200 kΩ, selectable
Output 1 alarm output, relay 250 V / 5 A AC
Connection IT distribution system
Rated frequency 50 Hz
Working frequency 47…63 Hz
Measuring voltage 12 VDC
Measuring current < 50 µA
Threshold setting Selectable by 6-position rotary switch
Threshold ranges 20 / 40 / 70 / 100 / 150 / 200 kΩ
Response time < 0.6 s
Accuracy ± 10 % of selected value
Power-on signalling Green LED “ON”
Alarm intervention Red LED “ALARM” and relay switching
Manual test Verifies the device’s correct operation
Reset Automatic
Hysteresis / reset value < 20 %
Alarm relay 1 SPDT changeover contact
Contact rating 5 A / 250 VAC at cosφ 1; 3 A / 250 VAC at cosφ 0.4; 5 A / 30 VDC
Safety Negative safety, normally de-energized relay
Auxiliary supply 230 V
Auxiliary supply tolerance 192…253 V
Auxiliary supply rated frequency 50 Hz
Frequency tolerance 47…63 Hz
Power consumption ≤ 4 VA
Insulation voltage rating 650 V
Impulse voltage test 5 kV, 1.2/50 µs, 0.5 J
Considered circuits impulse test Input, auxiliary supply, relay
AC voltage test 1 2 kV R.M.S., 50 Hz / 1 min
Considered circuits 1 Input, auxiliary supply, relay
AC voltage test 2 4 kV R.M.S., 50 Hz / 1 min
Considered circuits 2 All circuits and earth
Fast transient burst test According to IEC 801-4, severity level 4
Electrostatic discharge immunity According to IEC 801-2, severity level 4
High-frequency disturbance test 1 MHz damped oscillatory wave according to IEC 255-4
EMC test voltage 2.5 kV common mode, 1 kV series mode
Reference temperature 20 °C ± 2 °C
Nominal temperature range -5…40 °C
Limit temperature range -10…55 °C
Storage temperature range -25…70 °C
Relative humidity 45…75 %
Climatic suitability Tropicalized version for saline-humid-heat ambient
Housing depth 69 mm
Connection Screw terminals for cable up to 4 mm²
Mounting Snap-on mounting on 35 mm DIN rail according to EN 50022 or screw mounting
Option Kit for flush mounting, front frame 72 × 103 mm, panel cutout 70 × 46 mm
Housing material Self-extinguishing Makrolon
Protection degree IP40 front, IP20 terminals
Weight 350 g






Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    RI2A – Insulation monitor (4 Modul)

    • Iso D4 insulation monitor for continuous control of insulation towards earth
    • Suitable for IT systems with 24…400 VAC
    • Selectable alarm threshold from 20…200 kΩ
    • 6-position threshold setting by rotary switch
    • Alarm indication via red LED and relay output
    • Automatic reset and manual test for function checking
    • 1 SPDT changeover contact with 5 A / 250 VAC contact rating
    • 4-DIN-module housing for DIN rail, screw or optional flush mounting
    Datasheet

    Iso D4

    Insulation monitor for IT distribution systems, 4 DIN modules

    Type Insulation monitor for continuous control of insulation towards earth
    Model Iso D4
    Format 4 DIN modules according to DIN 43880
    Network type IT distribution system
    Network voltage 24…400 VAC
    Alarm threshold 20…200 kΩ, selectable
    Output 1 alarm output, relay 250 V / 5 A AC
    Connection IT distribution system
    Rated frequency 50 Hz
    Working frequency 47…63 Hz
    Measuring voltage 12 VDC
    Measuring current < 50 µA
    Threshold setting Selectable by 6-position rotary switch
    Threshold ranges 20 / 40 / 70 / 100 / 150 / 200 kΩ
    Response time < 0.6 s
    Accuracy ± 10 % of selected value
    Power-on signalling Green LED “ON”
    Alarm intervention Red LED “ALARM” and relay switching
    Manual test Verifies the device’s correct operation
    Reset Automatic
    Hysteresis / reset value < 20 %
    Alarm relay 1 SPDT changeover contact
    Contact rating 5 A / 250 VAC at cosφ 1; 3 A / 250 VAC at cosφ 0.4; 5 A / 30 VDC
    Safety Negative safety, normally de-energized relay
    Auxiliary supply 230 V
    Auxiliary supply tolerance 192…253 V
    Auxiliary supply rated frequency 50 Hz
    Frequency tolerance 47…63 Hz
    Power consumption ≤ 4 VA
    Insulation voltage rating 650 V
    Impulse voltage test 5 kV, 1.2/50 µs, 0.5 J
    Considered circuits impulse test Input, auxiliary supply, relay
    AC voltage test 1 2 kV R.M.S., 50 Hz / 1 min
    Considered circuits 1 Input, auxiliary supply, relay
    AC voltage test 2 4 kV R.M.S., 50 Hz / 1 min
    Considered circuits 2 All circuits and earth
    Fast transient burst test According to IEC 801-4, severity level 4
    Electrostatic discharge immunity According to IEC 801-2, severity level 4
    High-frequency disturbance test 1 MHz damped oscillatory wave according to IEC 255-4
    EMC test voltage 2.5 kV common mode, 1 kV series mode
    Reference temperature 20 °C ± 2 °C
    Nominal temperature range -5…40 °C
    Limit temperature range -10…55 °C
    Storage temperature range -25…70 °C
    Relative humidity 45…75 %
    Climatic suitability Tropicalized version for saline-humid-heat ambient
    Housing depth 69 mm
    Connection Screw terminals for cable up to 4 mm²
    Mounting Snap-on mounting on 35 mm DIN rail according to EN 50022 or screw mounting
    Option Kit for flush mounting, front frame 72 × 103 mm, panel cutout 70 × 46 mm
    Housing material Self-extinguishing Makrolon
    Protection degree IP40 front, IP20 terminals
    Weight 350 g






    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.