SITRANS FUS SONO 3300/FUS060


The SITRANS FUS SONO3300/SITRANS FUS060 flowmeter consists of a SITRANS FUS SONO 3300 sensor and a SITRANS FUS060 transmitter. The sensor is available in carbon steel and is fitted with integrated transducers. It also comes with signal cables enclosed in stainless steel pipes. The SITRANS FUS060 transmitter makes use of an advanced transit-time signal processing technology ensuring reliable and accurate signal detection for a wide range of processes.

 

The SITRANS FUS SONO 3300/SITRANS FUS060 flowmeter consists of a sensor and transmitter. For details and information about the transmitter, see SITRANS FUS060

Datasheet
User Manual
User Manual
  • Enduring – Excellent immunity against impurities and obstacles in the water
  • Reliable – Long time stability and linear measurement

 

Detail

 Measuring range
Qn 10 to 2200 m³/h (depending on size)
Nominal size

DN 50 to DN 300 (2″ to 12″)

Accuracy
±0.5% of flow rate
Operating pressure
Max. 40 bar (Max. 580 psi)
Operating temperature
-40 … 85 °C (-40 … 185 °F)
Medium temperature
-10 … 160 °C (14 … 320 °F)
 Design
2 paths
 Material
Carbon steel
 Approvals
ATEX

Application examples: hot and waste water









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    SITRANS FUS SONO 3300/FUS060

    The SITRANS FUS SONO3300/SITRANS FUS060 flowmeter consists of a SITRANS FUS SONO 3300 sensor and a SITRANS FUS060 transmitter. The sensor is available in carbon steel and is fitted with integrated transducers. It also comes with signal cables enclosed in stainless steel pipes. The SITRANS FUS060 transmitter makes use of an advanced transit-time signal processing technology ensuring reliable and accurate signal detection for a wide range of processes.

     

    The SITRANS FUS SONO 3300/SITRANS FUS060 flowmeter consists of a sensor and transmitter. For details and information about the transmitter, see SITRANS FUS060

    Datasheet
    User Manual
    User Manual
    • Enduring – Excellent immunity against impurities and obstacles in the water
    • Reliable – Long time stability and linear measurement

     

    Detail

     Measuring range
    Qn 10 to 2200 m³/h (depending on size)
    Nominal size

    DN 50 to DN 300 (2″ to 12″)

    Accuracy
    ±0.5% of flow rate
    Operating pressure
    Max. 40 bar (Max. 580 psi)
    Operating temperature
    -40 … 85 °C (-40 … 185 °F)
    Medium temperature
    -10 … 160 °C (14 … 320 °F)
     Design
    2 paths
     Material
    Carbon steel
     Approvals
    ATEX

    Application examples: hot and waste water