WIKA Models PGS23.100, PGS23.160 Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160


  • Up to 4 switch contacts per instrument
  • Also available with case filling for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with contacts for PLC applications
  • Instruments optionally available in safety version S3 per EN 837

Datasheet
User Manual
User Manual

Applications

  • Control and regulation of processes
  • Monitoring of plants and switching of circuits
  • For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive environments
  • Chemical industry, petrochemical industry, power plants, mining, on-/offshore, environmental technology, machine building and general plant construction

 

Description

Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model PGS23.1×0 switchGAUGE finds its use. Switch contacts (electrical switch contacts) make or break an electric control circuit dependent upon the pointer position of the indicating measuring instrument. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted using a removable adjustment key in the window.

Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Models PGS23.100, PGS23.160 Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160

    • Up to 4 switch contacts per instrument
    • Also available with case filling for high dynamic pressure loads or vibrations
    • Instruments with inductive contacts for use in hazardous areas
    • Instruments with contacts for PLC applications
    • Instruments optionally available in safety version S3 per EN 837

    Datasheet
    User Manual
    User Manual

    Applications

    • Control and regulation of processes
    • Monitoring of plants and switching of circuits
    • For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive environments
    • Chemical industry, petrochemical industry, power plants, mining, on-/offshore, environmental technology, machine building and general plant construction

     

    Description

    Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model PGS23.1×0 switchGAUGE finds its use. Switch contacts (electrical switch contacts) make or break an electric control circuit dependent upon the pointer position of the indicating measuring instrument. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
    The set pointer can be adjusted using a removable adjustment key in the window.

    Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels. As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.









    Technical advice: 03303 / 50 40 66