WIKA Models 432.36+8xx, 432.56+8xx Diaphragm pressure gauge with switch contacts For the process industry, high overload safety up to 40, 100 or 400 bar


  • High overload safety, optionally up to 40, 100 or 400 bar, due to the metallic pressure element limit stop, without liquid-filled measuring cell
  • Wide choice of special materials
  • Also available with liquid-filled case for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications


Datasheet
User Manual
User Manual

Applications

  • Control and regulation of processes at measuring points with increased overpressure and scale ranges from 0 … 25 mbar
  • Monitoring of plants and switching of electric circuits
  • For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive environments
  • Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction

 

Description

Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model 432.56 or 432.36 switchGAUGE finds its use.
Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instruments. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted using a removable adjustment key in the window.

Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.

The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.
As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Models 432.36+8xx, 432.56+8xx Diaphragm pressure gauge with switch contacts For the process industry, high overload safety up to 40, 100 or 400 bar

    • High overload safety, optionally up to 40, 100 or 400 bar, due to the metallic pressure element limit stop, without liquid-filled measuring cell
    • Wide choice of special materials
    • Also available with liquid-filled case for high dynamic pressure loads or vibrations
    • Instruments with inductive contacts for use in hazardous areas
    • Instruments with switch contact for PLC applications


    Datasheet
    User Manual
    User Manual

    Applications

    • Control and regulation of processes at measuring points with increased overpressure and scale ranges from 0 … 25 mbar
    • Monitoring of plants and switching of electric circuits
    • For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive environments
    • Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction

     

    Description

    Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model 432.56 or 432.36 switchGAUGE finds its use.
    Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instruments. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
    The set pointer can be adjusted using a removable adjustment key in the window.

    Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.

    The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.
    As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas.









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.