  • GammaFlash is a lightweight, rugged, battery-powered dose rate warning device for the detection of gamma and X-rays in the Ḣ*(10) ambient dose equivalent rate measurand.
  • Detector: Geiger-Müller counter tube with energy filter
  • It has a fixed warning threshold that triggers a visual and audible alarm when exceeded
  • The audible alarm can be acknowledged via a pushbutton on the housing perimeter
  • Below the preset warning threshold, the GammaFlash indicates the functional readiness and battery status via a red LED
  • By changing the blinking frequency of the optical single pulse display, an increase or decrease of the dose rate is indicated
  • Customized warning threshold between 7.5 µSv/h and 10 mSv/h can be implemented ex works
  • Easy to operate even with firefighter gloves on
  • The plastic housing is jet-proof, oil and petrol resistant
  • Thanks to a built-in magnet, the gamma radiation warning light can be attached to suitable metal surfaces if required
  • Possibility of individual labeling of the housing cover

Notice:

  • In the firefighter version, the GammaFlash is preset to the dose rate warning threshold of 25 µSv/h for determining the limit of a hazardous area
Datasheet

The Gamma radiation warning light GRAETZ GammaFlash is used to determine and set up exclusion zones when a specified local dose rate of gamma and X-ray radiation is detected. Exceeding the specified warning threshold is clearly indicated visually and acoustically. With its extremely compact and robust design, as well as a magnetic bottom – for attaching the device to metallic surfaces – this dose rate warning device is particularly suitable for use by fire departments, civil defense and disaster control forces.

  • Easy to operate, even with firefighter gloves on
  • Clear visual and audible alarm when the set warning threshold of the local dose rate is exceeded
  • Dust and splash protection as well as protection against short-term immersion in water (protection class IP67)
  • Oil and petrol resistant
  • Magnetic back for attachment to metal surfaces
  • Individualization of the housing with own logo or lettering possible

 

Technical Data

Measuring range Dose rate 1 µSv/h ≤ Ḣ*(10) ≤ 40 mSv/h
Overload capacity 1 Sv/h
Energy sector 40 keV – 1.3 MeV
Dose rate warning thresholds 1
Desired warning threshold can be ordered ex works in the range of 7.5 µSv/h – 10 mSv/h. Fire department: 25 µSv/h
Dimensions Ø 86 x 54 mm
Weight (incl. batteries) approx. 250 g
Protection class IP65 (Protected against water jets)

 

Individualization

  • For other applications, a customer-specific warning threshold between 7.5 μSv/h and 10 mSv/h can also be implemented ex works on request.
  • Individual labeling of the housing cover possible on request.








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Gamma radiation warning light GRAETZ GammaFlash

    • GammaFlash is a lightweight, rugged, battery-powered dose rate warning device for the detection of gamma and X-rays in the Ḣ*(10) ambient dose equivalent rate measurand.
    • Detector: Geiger-Müller counter tube with energy filter
    • It has a fixed warning threshold that triggers a visual and audible alarm when exceeded
    • The audible alarm can be acknowledged via a pushbutton on the housing perimeter
    • Below the preset warning threshold, the GammaFlash indicates the functional readiness and battery status via a red LED
    • By changing the blinking frequency of the optical single pulse display, an increase or decrease of the dose rate is indicated
    • Customized warning threshold between 7.5 µSv/h and 10 mSv/h can be implemented ex works
    • Easy to operate even with firefighter gloves on
    • The plastic housing is jet-proof, oil and petrol resistant
    • Thanks to a built-in magnet, the gamma radiation warning light can be attached to suitable metal surfaces if required
    • Possibility of individual labeling of the housing cover

    Notice:

    • In the firefighter version, the GammaFlash is preset to the dose rate warning threshold of 25 µSv/h for determining the limit of a hazardous area
    Datasheet

    The Gamma radiation warning light GRAETZ GammaFlash is used to determine and set up exclusion zones when a specified local dose rate of gamma and X-ray radiation is detected. Exceeding the specified warning threshold is clearly indicated visually and acoustically. With its extremely compact and robust design, as well as a magnetic bottom – for attaching the device to metallic surfaces – this dose rate warning device is particularly suitable for use by fire departments, civil defense and disaster control forces.

    • Easy to operate, even with firefighter gloves on
    • Clear visual and audible alarm when the set warning threshold of the local dose rate is exceeded
    • Dust and splash protection as well as protection against short-term immersion in water (protection class IP67)
    • Oil and petrol resistant
    • Magnetic back for attachment to metal surfaces
    • Individualization of the housing with own logo or lettering possible

     

    Technical Data

    Measuring range Dose rate 1 µSv/h ≤ Ḣ*(10) ≤ 40 mSv/h
    Overload capacity 1 Sv/h
    Energy sector 40 keV – 1.3 MeV
    Dose rate warning thresholds 1
    Desired warning threshold can be ordered ex works in the range of 7.5 µSv/h – 10 mSv/h. Fire department: 25 µSv/h
    Dimensions Ø 86 x 54 mm
    Weight (incl. batteries) approx. 250 g
    Protection class IP65 (Protected against water jets)

     

    Individualization

    • For other applications, a customer-specific warning threshold between 7.5 μSv/h and 10 mSv/h can also be implemented ex works on request.