WIKA Model PGT10 USB Bourdon tube pressure gauge with output signal Plastic case, with USB interface


  • USB interface for measured-value display on the PC
  • Non-contact sensor (wear-free)
  • Nominal size 50
  • Scale ranges 0 … 1,6 bar to 0 … 400 bar
Datasheet

Applications

  • Laboratory technology
  • General machine building

 

Description

Design
EN 837-1

Nominal size in mm
50

Accuracy class
2.5

Scale ranges
0 … 1.6 to 0 … 400 bar
or all other equivalent vacuum or combined pressure and vacuum ranges

Pressure limitation
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: Full scale value

Permissible temperature
Ambient: -20 … +60 °C
Medium: +60 °C maximum

Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 % / 10 K of the span

Process connection
Copper alloy, lower mount (LM)
G 1/4 B (male), 14 mm flats

Pressure element
Copper alloy, C-type

Movement
Copper alloy

Dial
Plastic, white, black lettering

Pointer
Plastic, black









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Model PGT10 USB Bourdon tube pressure gauge with output signal Plastic case, with USB interface

    • USB interface for measured-value display on the PC
    • Non-contact sensor (wear-free)
    • Nominal size 50
    • Scale ranges 0 … 1,6 bar to 0 … 400 bar
    Datasheet

    Applications

    • Laboratory technology
    • General machine building

     

    Description

    Design
    EN 837-1

    Nominal size in mm
    50

    Accuracy class
    2.5

    Scale ranges
    0 … 1.6 to 0 … 400 bar
    or all other equivalent vacuum or combined pressure and vacuum ranges

    Pressure limitation
    Steady: 3/4 x full scale value
    Fluctuating: 2/3 x full scale value
    Short time: Full scale value

    Permissible temperature
    Ambient: -20 … +60 °C
    Medium: +60 °C maximum

    Temperature effect
    When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 % / 10 K of the span

    Process connection
    Copper alloy, lower mount (LM)
    G 1/4 B (male), 14 mm flats

    Pressure element
    Copper alloy, C-type

    Movement
    Copper alloy

    Dial
    Plastic, white, black lettering

    Pointer
    Plastic, black









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.