testo 6454 – Compressed air meter DN50 (2“)


The testo 6453 compressed air meter DN40 (1½″) enables precise monitoring of compressed air consumption, flow, temperature and operating pressure with just one device. The integrated measuring section provides defined flow conditions and enables quick installation directly in the compressed air line.

  • Four measured variables: volumetric flow, totalizer, temperature and operating pressure
  • Volumetric flow measuring range: 20 … 6,830 l/min or 1.4 … 410 m³/h
  • Process connection: DN40 / R 1½
  • Integrated pressure measurement: -1 … +16 bar
  • TFT display: simultaneous display of three measured values
  • 2 × analog output: 4 … 20 mA, scalable
  • Calorimetric measuring principle: no moving wear parts
Datasheet
Operating Instructions

testo 6454 – Compressed Air Meter DN50 (2″) for Consumption, Flow, Pressure and Temperature Measurement

The testo 6454 is a stationary compressed air meter for continuous monitoring of compressed air consumption and operating conditions in industrial compressed air systems. The device combines four important measured variables in one compact measuring system: volumetric flow, total consumption, temperature and operating pressure.

This makes the testo 6454 suitable for consumption measurement as well as leak monitoring, consumption-based allocation of compressed air costs and analysis of peak loads. Continuous monitoring of compressed air consumption helps identify potential savings and enables better assessment of compressed air generation capacity utilization.

Four Measured Variables with One Device

The testo 6454 simultaneously measures:

  • Volumetric flow of the compressed air
  • Total consumption via the integrated totalizer
  • Medium temperature
  • Operating pressure

For many applications, this eliminates the need for an additional separate pressure measurement. The standard TFT display can show up to three measured values simultaneously directly at the measuring point.

Calorimetric Flow Measurement

Flow measurement is based on the calorimetric measuring principle. This means that no moving mechanical wear parts are required. The integrated inlet and outlet measuring section provides defined flow conditions and reduces installation-related measurement deviations.

For the testo 6454 in the DN50 version, the measuring range is:

  • Volumetric flow: 40 … 11,670 l/min
  • Standard volumetric flow: 2.5 … 700 m³/h
  • Flow velocity: 0.3 … 84 m/s

The specifications for volumetric flow, display and settings refer to standard volume according to DIN ISO 2533.

Integrated Pressure and Temperature Measurement

In addition to compressed air consumption, the testo 6454 also monitors the current operating pressure and medium temperature. This provides several important operating parameters of a compressed air line simultaneously.

Measured variable Measuring range
Volumetric flow 40 … 11,670 l/min
Standard volumetric flow 2.5 … 700 m³/h
Flow velocity 0.3 … 84 m/s
Totalizer 0 … 100,000,000 m³
Operating pressure -1 … +16 bar
Temperature -10 … +60 °C

Direct Integration into Control and Monitoring Systems

For further processing of the measured values, two scalable 4 … 20 mA analog outputs are available. These can be used to transmit flow, pressure or temperature, for example, to a PLC, process control system, data logger or energy management system.

The testo 6454 is supplied with an operating voltage of 18 … 30 V DC. Maximum current consumption is less than 80 mA.

Transparent Monitoring of Compressed Air Consumption

Continuous consumption measurement enables, among other things:

  • Measurement of compressed air consumption for individual machines or plant sections
  • Consumption-based allocation of compressed air costs
  • Detection of unusually high consumption
  • Support for leak monitoring
  • Analysis of peak loads
  • Monitoring of available compressed air generation capacity
  • Evaluation of energy-saving measures
  • Implementation of continuous compressed air monitoring

The compressed air meter therefore supports the systematic assessment of energy consumption and can be used, for example, as part of an energy or environmental management system according to ISO 50001 or ISO 14001.

Technical Data testo 6454

Technical characteristic testo 6454
Order number 0555 6454
Nominal diameter DN50 (2″)
Process connection R 2 thread
Flow measuring principle Calorimetric
Volumetric flow 40 … 11,670 l/min
Standard volumetric flow 2.5 … 700 m³/h
Flow velocity 0.3 … 84 m/s
Flow resolution 10 l/min / 0.1 m/s / 0.5 m³/h
Totalizer 0 … 100,000,000 m³
Pressure measuring range -1 … +16 bar
Pressure resolution 0.05 bar
Temperature measuring range -10 … +60 °C
Temperature accuracy ±0.5 K
Medium Compressed air
Medium temperature -10 … +60 °C
Pressure rating 16 bar
Minimum burst pressure 64 bar
Outputs 2 × 4 … 20 mA, scalable
Maximum load 500 Ω
Power supply 18 … 30 V DC
Current consumption < 80 mA
Display 1.44″ color display, 128 × 128 pixels
Ambient temperature 0 … +60 °C
Storage temperature -20 … +85 °C
Ingress protection IP65 / IP67
Weight approx. 2,650.5 g

Volumetric Flow Measurement Accuracy

The achievable measurement accuracy depends on the compressed air quality. Testo specifies the following values at a medium temperature of +23 °C:

  • Compressed air class 1-4-1 according to ISO 8573-1:2010: ±(2 % of reading + 0.5 % of full scale)
  • Compressed air class 3-4-4 according to ISO 8573-1:2010: ±(6 % of reading + 0.6 % of full scale)
  • Repeatability: 0.8 % of reading + 0.2 % of full scale

Typical Applications

  • Compressed air consumption measurement in production plants
  • Consumption monitoring of larger machines and plant sections
  • Measurement in main and distribution lines
  • Energy and cost monitoring
  • Leak monitoring
  • Peak-load analysis
  • Monitoring of the compressed air supply
  • Energy management according to ISO 50001
  • Environmental management according to ISO 14001

Advantages of the testo 6454

  • Four measured variables with just one measuring instrument
  • Integrated pressure and temperature measurement
  • Integrated inlet and outlet measuring section
  • Direct local indication via TFT color display
  • Simultaneous display of three measured values
  • Two scalable 4 … 20 mA outputs
  • Calorimetric measuring principle without moving wear parts
  • Suitable for high compressed air flow rates up to 700 m³/h
  • Easy integration into existing compressed air systems
  • Suitable for continuous energy and consumption monitoring

Scope of Delivery

  • testo 6454 compressed air meter DN50 (2″)
  • integrated inlet/outlet measuring section
  • analog output
  • integrated pressure measurement
  • operating instructions

The testo 6454 is particularly suitable for operators who want to continuously measure larger compressed air flow rates in DN50 lines while simultaneously monitoring flow, total consumption, operating pressure and temperature.





Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    testo 6454 – Compressed air meter DN50 (2“)

    The testo 6453 compressed air meter DN40 (1½″) enables precise monitoring of compressed air consumption, flow, temperature and operating pressure with just one device. The integrated measuring section provides defined flow conditions and enables quick installation directly in the compressed air line.

    • Four measured variables: volumetric flow, totalizer, temperature and operating pressure
    • Volumetric flow measuring range: 20 … 6,830 l/min or 1.4 … 410 m³/h
    • Process connection: DN40 / R 1½
    • Integrated pressure measurement: -1 … +16 bar
    • TFT display: simultaneous display of three measured values
    • 2 × analog output: 4 … 20 mA, scalable
    • Calorimetric measuring principle: no moving wear parts
    Datasheet
    Operating Instructions

    testo 6454 – Compressed Air Meter DN50 (2″) for Consumption, Flow, Pressure and Temperature Measurement

    The testo 6454 is a stationary compressed air meter for continuous monitoring of compressed air consumption and operating conditions in industrial compressed air systems. The device combines four important measured variables in one compact measuring system: volumetric flow, total consumption, temperature and operating pressure.

    This makes the testo 6454 suitable for consumption measurement as well as leak monitoring, consumption-based allocation of compressed air costs and analysis of peak loads. Continuous monitoring of compressed air consumption helps identify potential savings and enables better assessment of compressed air generation capacity utilization.

    Four Measured Variables with One Device

    The testo 6454 simultaneously measures:

    • Volumetric flow of the compressed air
    • Total consumption via the integrated totalizer
    • Medium temperature
    • Operating pressure

    For many applications, this eliminates the need for an additional separate pressure measurement. The standard TFT display can show up to three measured values simultaneously directly at the measuring point.

    Calorimetric Flow Measurement

    Flow measurement is based on the calorimetric measuring principle. This means that no moving mechanical wear parts are required. The integrated inlet and outlet measuring section provides defined flow conditions and reduces installation-related measurement deviations.

    For the testo 6454 in the DN50 version, the measuring range is:

    • Volumetric flow: 40 … 11,670 l/min
    • Standard volumetric flow: 2.5 … 700 m³/h
    • Flow velocity: 0.3 … 84 m/s

    The specifications for volumetric flow, display and settings refer to standard volume according to DIN ISO 2533.

    Integrated Pressure and Temperature Measurement

    In addition to compressed air consumption, the testo 6454 also monitors the current operating pressure and medium temperature. This provides several important operating parameters of a compressed air line simultaneously.

    Measured variable Measuring range
    Volumetric flow 40 … 11,670 l/min
    Standard volumetric flow 2.5 … 700 m³/h
    Flow velocity 0.3 … 84 m/s
    Totalizer 0 … 100,000,000 m³
    Operating pressure -1 … +16 bar
    Temperature -10 … +60 °C

    Direct Integration into Control and Monitoring Systems

    For further processing of the measured values, two scalable 4 … 20 mA analog outputs are available. These can be used to transmit flow, pressure or temperature, for example, to a PLC, process control system, data logger or energy management system.

    The testo 6454 is supplied with an operating voltage of 18 … 30 V DC. Maximum current consumption is less than 80 mA.

    Transparent Monitoring of Compressed Air Consumption

    Continuous consumption measurement enables, among other things:

    • Measurement of compressed air consumption for individual machines or plant sections
    • Consumption-based allocation of compressed air costs
    • Detection of unusually high consumption
    • Support for leak monitoring
    • Analysis of peak loads
    • Monitoring of available compressed air generation capacity
    • Evaluation of energy-saving measures
    • Implementation of continuous compressed air monitoring

    The compressed air meter therefore supports the systematic assessment of energy consumption and can be used, for example, as part of an energy or environmental management system according to ISO 50001 or ISO 14001.

    Technical Data testo 6454

    Technical characteristic testo 6454
    Order number 0555 6454
    Nominal diameter DN50 (2″)
    Process connection R 2 thread
    Flow measuring principle Calorimetric
    Volumetric flow 40 … 11,670 l/min
    Standard volumetric flow 2.5 … 700 m³/h
    Flow velocity 0.3 … 84 m/s
    Flow resolution 10 l/min / 0.1 m/s / 0.5 m³/h
    Totalizer 0 … 100,000,000 m³
    Pressure measuring range -1 … +16 bar
    Pressure resolution 0.05 bar
    Temperature measuring range -10 … +60 °C
    Temperature accuracy ±0.5 K
    Medium Compressed air
    Medium temperature -10 … +60 °C
    Pressure rating 16 bar
    Minimum burst pressure 64 bar
    Outputs 2 × 4 … 20 mA, scalable
    Maximum load 500 Ω
    Power supply 18 … 30 V DC
    Current consumption < 80 mA
    Display 1.44″ color display, 128 × 128 pixels
    Ambient temperature 0 … +60 °C
    Storage temperature -20 … +85 °C
    Ingress protection IP65 / IP67
    Weight approx. 2,650.5 g

    Volumetric Flow Measurement Accuracy

    The achievable measurement accuracy depends on the compressed air quality. Testo specifies the following values at a medium temperature of +23 °C:

    • Compressed air class 1-4-1 according to ISO 8573-1:2010: ±(2 % of reading + 0.5 % of full scale)
    • Compressed air class 3-4-4 according to ISO 8573-1:2010: ±(6 % of reading + 0.6 % of full scale)
    • Repeatability: 0.8 % of reading + 0.2 % of full scale

    Typical Applications

    • Compressed air consumption measurement in production plants
    • Consumption monitoring of larger machines and plant sections
    • Measurement in main and distribution lines
    • Energy and cost monitoring
    • Leak monitoring
    • Peak-load analysis
    • Monitoring of the compressed air supply
    • Energy management according to ISO 50001
    • Environmental management according to ISO 14001

    Advantages of the testo 6454

    • Four measured variables with just one measuring instrument
    • Integrated pressure and temperature measurement
    • Integrated inlet and outlet measuring section
    • Direct local indication via TFT color display
    • Simultaneous display of three measured values
    • Two scalable 4 … 20 mA outputs
    • Calorimetric measuring principle without moving wear parts
    • Suitable for high compressed air flow rates up to 700 m³/h
    • Easy integration into existing compressed air systems
    • Suitable for continuous energy and consumption monitoring

    Scope of Delivery

    • testo 6454 compressed air meter DN50 (2″)
    • integrated inlet/outlet measuring section
    • analog output
    • integrated pressure measurement
    • operating instructions

    The testo 6454 is particularly suitable for operators who want to continuously measure larger compressed air flow rates in DN50 lines while simultaneously monitoring flow, total consumption, operating pressure and temperature.





    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.