HySense FO310 – Force Sensors Based on the Compression Force Principle


  • Measurement principle: compression force
  • Output signal 4 … 20 mA
 
Data sheet
Catalog excerpt
  • Measurement principle: compression force
  • Output signal 4 … 20 mA
  • Electrical connection: 5-pin device connector, M16 x 0.75
  • Protection class (EN 60529 / IEC 529) IP 65
  • Housing material: steel
  • Signal type: three-wire
  • Supply voltage Ub 10 … 30 VDC
  • Current consumption < 50 mA
  • Error limit (23 °C) < 0.5 % of full scale
  • Operating load 130 % of full scale
  • Limit load 150 % of full scale
  • Breaking load 300 % of full scale
  • Max. dynamic load 70 % (according to DIN 50100)
  • Rated measuring displacement 0.1 mm
  • Temperature coefficient 0.2 % / 10 K
  • Calibration in N
  • Calibration tolerance < 0.5 % of full scale
  • Ambient temperature 0 … +60 °C (sensor -30 … +80 °C)
  • Storage temperature 0 … +60 °C
  • EMC test IEC 801-2/4/5, EN 55011, EN 55022






Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    HySense FO310 – Force Sensors Based on the Compression Force Principle

    • Measurement principle: compression force
    • Output signal 4 … 20 mA
     
    Data sheet
    Catalog excerpt
    • Measurement principle: compression force
    • Output signal 4 … 20 mA
    • Electrical connection: 5-pin device connector, M16 x 0.75
    • Protection class (EN 60529 / IEC 529) IP 65
    • Housing material: steel
    • Signal type: three-wire
    • Supply voltage Ub 10 … 30 VDC
    • Current consumption < 50 mA
    • Error limit (23 °C) < 0.5 % of full scale
    • Operating load 130 % of full scale
    • Limit load 150 % of full scale
    • Breaking load 300 % of full scale
    • Max. dynamic load 70 % (according to DIN 50100)
    • Rated measuring displacement 0.1 mm
    • Temperature coefficient 0.2 % / 10 K
    • Calibration in N
    • Calibration tolerance < 0.5 % of full scale
    • Ambient temperature 0 … +60 °C (sensor -30 … +80 °C)
    • Storage temperature 0 … +60 °C
    • EMC test IEC 801-2/4/5, EN 55011, EN 55022