Technical Data
Measuring range | 0°-30°C, -40°C to +60°C, 0°–50°C, 0°-100°C, 0°-250°C, 0°-500°C, 0°-1000°C |
Spectral range | 8-14 μm |
Emissivity correction | 1,0 to 0,1 adjustable on Controller |
Dimensions | Length 80mm x width 125mm x height 57mm |
Permissible ambient temperature | 0°C to +50°C |
Distance to measuring spot | 100mm : 2mm | 50mm : 8mm | 1:1 depending on Sensor |
Accuracy | +/- 1% of reading |
Repeat accuracy | 0,5°C (0-100°C), 1,0°C (over 100°C) |
Reaction time | 60ms |
Resolution | 1/10°C |
Outputs | 0-20mA, 4-20mA, 0-10VDC selectable on Controller |
Weight Controller | 680 Gram |
Load | max 500 Ohm |
Trigger/Holdfunction | 24 VDC input |
Power supply | 230 VAC, 115 VAC, 24 VDC (18-36 VDC) |
Cable entry | PG7 |
Delivery scope | Basic controller and sensor with 3m sensor cable (extendable up to 40m) |
Options | Bargraph display in the housing cover, relay contact for over-/undertemperature, adjustable integration time/measurement reassurance |