Series 6 – Ultramat6


  • High selectivity thanks to two-layer detector and optical coupler: reliable measurements even in complex gas mixtures
  • Low detection limits: Measurements at low concentrations
  • Corrosion-resistant materials in the gas channel (optional): Measurement possible in highly corrosive measuring gases
  • Cleanable analysis cuvettes: Cost savings thanks to further use in case of contamination
  • Electronics and physics: Gas-tight separation, purging is possible, IP65: Long service life even in harsh environments
Datasheet

The experts in IR-active components

Most frequently used for sophisticated applications, the ULTRAMAT 6 must meet high standards with regard to reliability and measurement quality. This is guaranteed by modern electronics, ease of operation, and a physical element that is adapted to the measurement task.

Also for complex gas mixtures

The ULTRAMAT 6E measures up to four and the ULTRAMAT 6F up to two infrared-active components in a single device. Using optical couplers and the optional use of optical filters to increase selectivity means that the measurement of complex gas mixtures is also possible in many cases. This ensures measurements of low concentrations as well as low detection limits.

 

Appropriate materials in the gas channel allow the analytical devices to be used even for measurements of gas mixtures with corrosive components or corrosive measuring components. Gas-tight separation of electronics and physical components when using the field device design with class IP65 protection and a purging gas connection guarantees a long service life even under harsh ambient conditions. The field device design is also the basic variant for the optional heating of the analysis unit for measuring high-boiling components and for use in hazardous zones.

Technical specifications

Max. number of components
4
Components
E.g., CO, CO2, NO, SO2, CH4 Hydrocarbons
Minimal measuring range

Component specific: 0–5/0–100 ppm

Housing
19″ rack / field housing








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Series 6 – Ultramat6

    • High selectivity thanks to two-layer detector and optical coupler: reliable measurements even in complex gas mixtures
    • Low detection limits: Measurements at low concentrations
    • Corrosion-resistant materials in the gas channel (optional): Measurement possible in highly corrosive measuring gases
    • Cleanable analysis cuvettes: Cost savings thanks to further use in case of contamination
    • Electronics and physics: Gas-tight separation, purging is possible, IP65: Long service life even in harsh environments
    Datasheet

    The experts in IR-active components

    Most frequently used for sophisticated applications, the ULTRAMAT 6 must meet high standards with regard to reliability and measurement quality. This is guaranteed by modern electronics, ease of operation, and a physical element that is adapted to the measurement task.

    Also for complex gas mixtures

    The ULTRAMAT 6E measures up to four and the ULTRAMAT 6F up to two infrared-active components in a single device. Using optical couplers and the optional use of optical filters to increase selectivity means that the measurement of complex gas mixtures is also possible in many cases. This ensures measurements of low concentrations as well as low detection limits.

     

    Appropriate materials in the gas channel allow the analytical devices to be used even for measurements of gas mixtures with corrosive components or corrosive measuring components. Gas-tight separation of electronics and physical components when using the field device design with class IP65 protection and a purging gas connection guarantees a long service life even under harsh ambient conditions. The field device design is also the basic variant for the optional heating of the analysis unit for measuring high-boiling components and for use in hazardous zones.

    Technical specifications

    Max. number of components
    4
    Components
    E.g., CO, CO2, NO, SO2, CH4 Hydrocarbons
    Minimal measuring range

    Component specific: 0–5/0–100 ppm

    Housing
    19″ rack / field housing








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.