CA 6418 ground resistance clamp meter


  • Earth clamp meter with elongated measuring head – specifically designed for flat earth conductors that cannot be enclosed by conventional round clamps
  • Loop resistance measurement without disconnecting the conductor and without auxiliary earth stakes
  • Adjustable resistance and current alarms – reliable warning when defined limit values are exceeded
  • Automatic air-gap compensation during switch-on for stable and reproducible measurement results
  • Automatic PRE-HOLD mode – measured values remain displayed when the clamp is opened
  • Storage of 300 time-stamped measured values directly in the instrument
  • On-site adjustment without returning the instrument to the manufacturer using the optional CL1 calibration loop
Data sheet
Operating instructions

CA 6418 earth clamp meter with elongated jaw for earth tapes
The Chauvin Arnoux CA 6418 earth clamp meter is specifically designed for testing earth loops on flat earth tapes. Its elongated measuring jaw reliably encloses flat steel tapes without disconnecting the conductor and without the use of auxiliary earth stakes. The instrument is designed for daily use under demanding conditions.

The CA 6418 measures the loop impedance of an earthing network non-invasively using the clamp measurement principle: an excitation winding in the measuring jaw generates a defined AC voltage, while a receiver winding measures the resulting current. The loop impedance is then calculated from these values. Its particular strength is the elongated measuring jaw, which can enclose flat earth tapes of different widths that cannot be measured using conventional round clamps. In addition to resistance measurements, the instrument measures leakage currents in the earthing network and provides an adjustable alarm when defined limit values are exceeded. This makes the instrument suitable for both routine testing and safety-critical inspections.

Your benefits at a glance

  • Elongated measuring jaw specifically designed for earth tapes – enables reliable measurements on flat earth tapes that cannot be enclosed by conventional round clamps
  • Measurements without disconnecting the conductor and without auxiliary earth stakes – saves time and enables testing even in difficult-to-access environments
  • On-site adjustment without returning the instrument to the manufacturer – the optional CL1 calibration loop with 5 fixed resistance values enables independent testing and adjustment of the clamp directly via the integrated setup menu
  • Adjustable resistance and current alarms – provides reliable warnings when defined limit values are exceeded
  • Automatic air-gap compensation during switch-on – ensures stable and reproducible measurement results
  • Automatic PRE-HOLD mode – freezes the measured value on the display when the clamp is opened
  • Memory for 300 time-stamped measurements directly in the instrument

Typical applications

  • Earthing tests on lightning protection systems with earth tapes
  • Earthing tests in areas where auxiliary earth stakes cannot be inserted into the ground
  • Parallel earthing measurements in high- and low-voltage transformer substations
  • Earthing tests in urban areas and Faraday-shielded buildings
  • Measurements on telecommunications cable networks, including shield earthing and common-mode currents
  • Earthing checks along railway lines, including poles, rails and fences
  • Testing earthing systems on above-ground and underground pipelines
  • Testing interconnected earthing systems and foundation earth electrodes

Technical highlights

  • Loop resistance: 0.010 Ω to 1200 Ω
  • Current measurement: 0.5 mA to 20 A
  • Adjustable resistance and current alarms
  • Clamping capacity for earth tapes measuring 30 × 40 mm or 20 × 55 mm, or conductors up to Ø 32 mm
  • Safety category: IEC 61010 – 100 V CAT IV / 150 V CAT III
  • Degree of protection: IP40
  • Memory: 300 time-stamped measured values
  • Battery life: 2400 measurements of 30 seconds each

Accessories
The optional CL1 calibration loop enables verification of the displayed values and independent adjustment of the clamp via the integrated setup menu – without returning the instrument to the manufacturer.

Scope of delivery

  • 1 CA 6418 earth clamp meter
  • 4 alkaline 1.5 V batteries (LR6 / AA)
  • 1 carrying case
  • Quick-start guide included and operating instructions in 5 languages available for download

Technical data

Display digital
Internal memory Yes
Printer connection
Integrated printer
Limit value indication Yes
Low-resistance measurement
Selective earth resistance measurement
Earth loop measurement
Soil resistivity measurement
Leakage current measurement with adapter
Interface
Bluetooth interface
Measured value memory Yes
Test voltage
Test current
Test frequency
Degree of protection (IP)

 







Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    CA 6418 ground resistance clamp meter

    • Earth clamp meter with elongated measuring head – specifically designed for flat earth conductors that cannot be enclosed by conventional round clamps
    • Loop resistance measurement without disconnecting the conductor and without auxiliary earth stakes
    • Adjustable resistance and current alarms – reliable warning when defined limit values are exceeded
    • Automatic air-gap compensation during switch-on for stable and reproducible measurement results
    • Automatic PRE-HOLD mode – measured values remain displayed when the clamp is opened
    • Storage of 300 time-stamped measured values directly in the instrument
    • On-site adjustment without returning the instrument to the manufacturer using the optional CL1 calibration loop
    Data sheet
    Operating instructions

    CA 6418 earth clamp meter with elongated jaw for earth tapes
    The Chauvin Arnoux CA 6418 earth clamp meter is specifically designed for testing earth loops on flat earth tapes. Its elongated measuring jaw reliably encloses flat steel tapes without disconnecting the conductor and without the use of auxiliary earth stakes. The instrument is designed for daily use under demanding conditions.

    The CA 6418 measures the loop impedance of an earthing network non-invasively using the clamp measurement principle: an excitation winding in the measuring jaw generates a defined AC voltage, while a receiver winding measures the resulting current. The loop impedance is then calculated from these values. Its particular strength is the elongated measuring jaw, which can enclose flat earth tapes of different widths that cannot be measured using conventional round clamps. In addition to resistance measurements, the instrument measures leakage currents in the earthing network and provides an adjustable alarm when defined limit values are exceeded. This makes the instrument suitable for both routine testing and safety-critical inspections.

    Your benefits at a glance

    • Elongated measuring jaw specifically designed for earth tapes – enables reliable measurements on flat earth tapes that cannot be enclosed by conventional round clamps
    • Measurements without disconnecting the conductor and without auxiliary earth stakes – saves time and enables testing even in difficult-to-access environments
    • On-site adjustment without returning the instrument to the manufacturer – the optional CL1 calibration loop with 5 fixed resistance values enables independent testing and adjustment of the clamp directly via the integrated setup menu
    • Adjustable resistance and current alarms – provides reliable warnings when defined limit values are exceeded
    • Automatic air-gap compensation during switch-on – ensures stable and reproducible measurement results
    • Automatic PRE-HOLD mode – freezes the measured value on the display when the clamp is opened
    • Memory for 300 time-stamped measurements directly in the instrument

    Typical applications

    • Earthing tests on lightning protection systems with earth tapes
    • Earthing tests in areas where auxiliary earth stakes cannot be inserted into the ground
    • Parallel earthing measurements in high- and low-voltage transformer substations
    • Earthing tests in urban areas and Faraday-shielded buildings
    • Measurements on telecommunications cable networks, including shield earthing and common-mode currents
    • Earthing checks along railway lines, including poles, rails and fences
    • Testing earthing systems on above-ground and underground pipelines
    • Testing interconnected earthing systems and foundation earth electrodes

    Technical highlights

    • Loop resistance: 0.010 Ω to 1200 Ω
    • Current measurement: 0.5 mA to 20 A
    • Adjustable resistance and current alarms
    • Clamping capacity for earth tapes measuring 30 × 40 mm or 20 × 55 mm, or conductors up to Ø 32 mm
    • Safety category: IEC 61010 – 100 V CAT IV / 150 V CAT III
    • Degree of protection: IP40
    • Memory: 300 time-stamped measured values
    • Battery life: 2400 measurements of 30 seconds each

    Accessories
    The optional CL1 calibration loop enables verification of the displayed values and independent adjustment of the clamp via the integrated setup menu – without returning the instrument to the manufacturer.

    Scope of delivery

    • 1 CA 6418 earth clamp meter
    • 4 alkaline 1.5 V batteries (LR6 / AA)
    • 1 carrying case
    • Quick-start guide included and operating instructions in 5 languages available for download

    Technical data

    Display digital
    Internal memory Yes
    Printer connection
    Integrated printer
    Limit value indication Yes
    Low-resistance measurement
    Selective earth resistance measurement
    Earth loop measurement
    Soil resistivity measurement
    Leakage current measurement with adapter
    Interface
    Bluetooth interface
    Measured value memory Yes
    Test voltage
    Test current
    Test frequency
    Degree of protection (IP)

     







    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.