WIKA Models DPGS43.100, DPGS43.160 Differential pressure gauge with switch contacts For the process industry, all-metal media chamber


  • Differential pressure measuring ranges from 0 … 16 mbar
  • High working pressure (static pressure) and high overload safety up to 40 bar
  • Also available with liquid-filled case for high dynamic pressure loads or vibrations
  • Instruments with inductive contacts for use in hazardous areas
  • Instruments with switch contact for PLC applications


Datasheet
User Manual
User Manual

Applications

  • Control and regulation of processes
  • Monitoring of plants and switching of circuits
  • For measuring points with increased differential overpressure
  • Filter and pump monitoring
  • Level measurement on closed vessels

 

Description

Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model DPGS43.1×0 switchGAUGE finds its use. Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the pointer position of the pressure gauge. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted using a removable adjustment key in the window.

Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The differential pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.
As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Models DPGS43.100, DPGS43.160 Differential pressure gauge with switch contacts For the process industry, all-metal media chamber

    • Differential pressure measuring ranges from 0 … 16 mbar
    • High working pressure (static pressure) and high overload safety up to 40 bar
    • Also available with liquid-filled case for high dynamic pressure loads or vibrations
    • Instruments with inductive contacts for use in hazardous areas
    • Instruments with switch contact for PLC applications


    Datasheet
    User Manual
    User Manual

    Applications

    • Control and regulation of processes
    • Monitoring of plants and switching of circuits
    • For measuring points with increased differential overpressure
    • Filter and pump monitoring
    • Level measurement on closed vessels

     

    Description

    Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model DPGS43.1×0 switchGAUGE finds its use. Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the pointer position of the pressure gauge. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
    The set pointer can be adjusted using a removable adjustment key in the window.

    Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point. The differential pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.
    As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.