GRAETZ CE-Telescope


  • For measuring high dose rates/pulse rates from a safe distance
  • For measurements in poorly accessible measuring locations
  • Easy connection with the X5C plus SE, X5C FW dose rate meters and the X5C plus calibratable dose rate meter via contact row using snap-in technology
  • Safe connection of telescope and base unit without plug or cable (only via contact row)
  • Telescope made of stainless steel, continuously extendable up to 4 m total length
  • Torsion-proof connection between measuring head and electronics through internally routed ribbon cable
  • Automatic measuring range switchover
  • Display of dose rate at the operator’s location at the push of a button
  • Voltage supply from the dose rate meter
  • Energy range, measuring range, measured variable correspond to the data of the respective connected probes

Note for use by fire departments:

  • Possibility of connecting the X50ZS dose rate meter by means of a special adaptation module
Datasheet

With the GRAETZ CE-Telescope, measurements of dose rates & pulse rates can be performed from a safe distance. Even measuring locations that are difficult to access can be reached more easily with the stainless steel telescope. The telescope can be equipped with a wide variety of measuring probes from GRAETZ. There is also the possibility of an easy connection with the dose rate meters of the GRAETZ-X5 series.

  • Large operating radius for safe measurements
  • Sturdy stainless steel telescope with a robust housing
  • Safety through practical application of the quadratic distance law in radiation protection
  • Different measuring ranges selectable by plug-in probes from the GRAETZ probe program
  • Can be combined with the dose rate meters of the GRAETZ-X5 series

 

Energy range, measuring range, measured variable correspond to the data of the respective connected probe.

Type Radiation Energy sector Measuring range Measured variable PTB-
Approval *
18509 CE γ 55 keV – 1.3 MeV 50 μSv/h – 1 Sv/h H*(10) 23.71/05.01
18529 CE γ 70 keV – 3 MeV 0.5 mSv/h – 10 Sv/h H*(10) 23.71/05.02
18545 CE γ 40 keV – 1.3 MeV 150 nSv/h – 200 μSv/h H*(10) 23.71/05.03
18550 CE γ 40 keV – 1.3 MeV 10 μSv/h – 20 mSv/h H*(10) 23.71/05.04
18526 D α, β, γ 0 – 20 kImp/s
Background: 25 imp/min
18559 C γ ND: 50 keV – 1.3 MeV
HD: 65 keV – 3 MeV
1.5 μSv/h – 10 Sv/h H*(10)

in conjunction with the calibratable dose rate meter X5C plus

 

Accessories

GRAETZ telescopic adapter

optionally for a dose rate meter of the GRAETZ-X5C series or GammaTwin S

  • Simple telescope for measurement in inaccessible places
  • 3 telescope elements with a length of 1.5 m each
  • To accommodate X5C plus SE, X5C FW or the calibratable dose rate meter X5C plus for dose rate and pulse measurements or GammaTwin S for pulse measurements
  • Retaining clip for holding the GRAETZ probes
  • For scrap monitoring or for detecting radioactive sources with the GRAETZ 2002 scintillation probe.
  • Spiral cable for connecting dose rate meter and probe
  • Optional accessories: case to hold dose rate meter, probe and cable









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    GRAETZ CE-Telescope

    • For measuring high dose rates/pulse rates from a safe distance
    • For measurements in poorly accessible measuring locations
    • Easy connection with the X5C plus SE, X5C FW dose rate meters and the X5C plus calibratable dose rate meter via contact row using snap-in technology
    • Safe connection of telescope and base unit without plug or cable (only via contact row)
    • Telescope made of stainless steel, continuously extendable up to 4 m total length
    • Torsion-proof connection between measuring head and electronics through internally routed ribbon cable
    • Automatic measuring range switchover
    • Display of dose rate at the operator’s location at the push of a button
    • Voltage supply from the dose rate meter
    • Energy range, measuring range, measured variable correspond to the data of the respective connected probes

    Note for use by fire departments:

    • Possibility of connecting the X50ZS dose rate meter by means of a special adaptation module
    Datasheet

    With the GRAETZ CE-Telescope, measurements of dose rates & pulse rates can be performed from a safe distance. Even measuring locations that are difficult to access can be reached more easily with the stainless steel telescope. The telescope can be equipped with a wide variety of measuring probes from GRAETZ. There is also the possibility of an easy connection with the dose rate meters of the GRAETZ-X5 series.

    • Large operating radius for safe measurements
    • Sturdy stainless steel telescope with a robust housing
    • Safety through practical application of the quadratic distance law in radiation protection
    • Different measuring ranges selectable by plug-in probes from the GRAETZ probe program
    • Can be combined with the dose rate meters of the GRAETZ-X5 series

     

    Energy range, measuring range, measured variable correspond to the data of the respective connected probe.

    Type Radiation Energy sector Measuring range Measured variable PTB-
    Approval *
    18509 CE γ 55 keV – 1.3 MeV 50 μSv/h – 1 Sv/h H*(10) 23.71/05.01
    18529 CE γ 70 keV – 3 MeV 0.5 mSv/h – 10 Sv/h H*(10) 23.71/05.02
    18545 CE γ 40 keV – 1.3 MeV 150 nSv/h – 200 μSv/h H*(10) 23.71/05.03
    18550 CE γ 40 keV – 1.3 MeV 10 μSv/h – 20 mSv/h H*(10) 23.71/05.04
    18526 D α, β, γ 0 – 20 kImp/s
    Background: 25 imp/min
    18559 C γ ND: 50 keV – 1.3 MeV
    HD: 65 keV – 3 MeV
    1.5 μSv/h – 10 Sv/h H*(10)

    in conjunction with the calibratable dose rate meter X5C plus

     

    Accessories

    GRAETZ telescopic adapter

    optionally for a dose rate meter of the GRAETZ-X5C series or GammaTwin S

    • Simple telescope for measurement in inaccessible places
    • 3 telescope elements with a length of 1.5 m each
    • To accommodate X5C plus SE, X5C FW or the calibratable dose rate meter X5C plus for dose rate and pulse measurements or GammaTwin S for pulse measurements
    • Retaining clip for holding the GRAETZ probes
    • For scrap monitoring or for detecting radioactive sources with the GRAETZ 2002 scintillation probe.
    • Spiral cable for connecting dose rate meter and probe
    • Optional accessories: case to hold dose rate meter, probe and cable









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.