The Huminator II offers the possibility to perform a rapid and
easy humidity calibration of measuring instruments, sensors
and data loggers of all manufacturers.

Datasheet

All advantages at a glance

  •  Wide temperature and humidity range from 5°C to 50°C
     and from 5%RH to 95%RH
  • New touch display enables a fast and intuitive operation
  • Graphical and tabular view as well as storage and
    evaluation of measured values
  • Integrated, easily accessible and replaceable reference
    sensor, that eliminates the need for an external reference
    system
  • Possibility to program measuring points and procedures
    individuallyn

Easy operation, fast regulation, good stability and homogeneity

  • Fast stabilisation time (e.g. 3 min from 35%RH to 80%RH
    at 25°C)
  • Highest measuring stability due to optimal insulation of the
    chamber and high-end sealing adapter plate
  • Large measuring chamber (Ø 160 mm, depth 320 mm)
  • No condensation inside the measuring chamber through a
    regulation along the dew point
  • Guaranteed mobility- the compact size and the minimal
    weight ensure an extremely flexible use of the Huminator II








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Huminator II Precision Humidity Generator

    The Huminator II offers the possibility to perform a rapid and
    easy humidity calibration of measuring instruments, sensors
    and data loggers of all manufacturers.

    Datasheet

    All advantages at a glance

    •  Wide temperature and humidity range from 5°C to 50°C
       and from 5%RH to 95%RH
    • New touch display enables a fast and intuitive operation
    • Graphical and tabular view as well as storage and
      evaluation of measured values
    • Integrated, easily accessible and replaceable reference
      sensor, that eliminates the need for an external reference
      system
    • Possibility to program measuring points and procedures
      individuallyn

    Easy operation, fast regulation, good stability and homogeneity

    • Fast stabilisation time (e.g. 3 min from 35%RH to 80%RH
      at 25°C)
    • Highest measuring stability due to optimal insulation of the
      chamber and high-end sealing adapter plate
    • Large measuring chamber (Ø 160 mm, depth 320 mm)
    • No condensation inside the measuring chamber through a
      regulation along the dew point
    • Guaranteed mobility- the compact size and the minimal
      weight ensure an extremely flexible use of the Huminator II