IAW with remote probe – Transmitters for humidity and temperature can be combined with different probes


  • Operating temp. up to 200 °C
  • Accuracy : ±1,5 % RH
  • On-site calibration
  • IP65
  • Stainless steel sensor tube
  • Modulair, can be combined
Datasheet

The transmitter IAW, (wall mounted), can be combined with any probe of the S series. The IAW-transmitter combined with the probe SZKA.0H (pictured here) can measure relative humidity and temperature in operating temperatures up to 200 °C. Combined with the probe SZKA.HD in operating temperatures up to 160 °C and at pressures of up to 25 bar. Additionally there is the option for resistance to ammonia.

The integrated hx processor can calculate further humidity values and apply them to the two outputs. With the RS485 standard all of the hx-values can be read simultaneously. Due to the digitisation of signal processing, the measurement accuracy for humidity achieves excellent values of ±1.5 % RH. In temperature measurement, the platinum resistance sensor achieves tolerances of ±0.15 K.

 

Options

  • Modbus
  • Display
  • hx converter
  • Pressure-resistant up to 25 bar
  • Pressure-resistant up to 10 bar
  • Ammonia-resistant
  • Exchangeable

 

Technical data
Relative Humidity 0…100 % RH
Temperature -60 … + 160 °C
-80 … + 200 °C
Dew point temperature -20 … +70 °C
Wet bulb temperature -10 … +50 °C
Absolute humidity 0 … 20g/m³
Mixing ratio 0 … 100g/kg dry air
Enthalpy 0 … 80kJ/kg
Signal output 0…1 V
0…10 V
4…20 mA
RS232, RS485 Modbus
Supply voltage 6 … 30 V DC / 6…26 VAC
15 … 30 V DC / 13…26 VAC
10 … 30 V DC
5 … 30 V DC








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    IAW with remote probe – Transmitters for humidity and temperature can be combined with different probes

    • Operating temp. up to 200 °C
    • Accuracy : ±1,5 % RH
    • On-site calibration
    • IP65
    • Stainless steel sensor tube
    • Modulair, can be combined
    Datasheet

    The transmitter IAW, (wall mounted), can be combined with any probe of the S series. The IAW-transmitter combined with the probe SZKA.0H (pictured here) can measure relative humidity and temperature in operating temperatures up to 200 °C. Combined with the probe SZKA.HD in operating temperatures up to 160 °C and at pressures of up to 25 bar. Additionally there is the option for resistance to ammonia.

    The integrated hx processor can calculate further humidity values and apply them to the two outputs. With the RS485 standard all of the hx-values can be read simultaneously. Due to the digitisation of signal processing, the measurement accuracy for humidity achieves excellent values of ±1.5 % RH. In temperature measurement, the platinum resistance sensor achieves tolerances of ±0.15 K.

     

    Options

    • Modbus
    • Display
    • hx converter
    • Pressure-resistant up to 25 bar
    • Pressure-resistant up to 10 bar
    • Ammonia-resistant
    • Exchangeable

     

    Technical data
    Relative Humidity 0…100 % RH
    Temperature -60 … + 160 °C
    -80 … + 200 °C
    Dew point temperature -20 … +70 °C
    Wet bulb temperature -10 … +50 °C
    Absolute humidity 0 … 20g/m³
    Mixing ratio 0 … 100g/kg dry air
    Enthalpy 0 … 80kJ/kg
    Signal output 0…1 V
    0…10 V
    4…20 mA
    RS232, RS485 Modbus
    Supply voltage 6 … 30 V DC / 6…26 VAC
    15 … 30 V DC / 13…26 VAC
    10 … 30 V DC
    5 … 30 V DC








    Technical advice: 03303 / 50 40 66