Hydrant test meter (portable)


  • Material • Aluminum alloy • fiberglass-reinforced plastic
  • Maximum working pressure 16 bar / 230 PSI
  • Operating temperature 10°C to 60°C
  • Water splash protection IP 65
  • Flow ranges • DN 40 (1.5″): 100 l/min to 1,000 l/min • DN 65 (2.5″): 300 l/min to 2,500 l/min • DN 80 (3″): 500 l/min to 3,000 l/min • DN 100 (4″): 1,000 l/min to 5,000 l/min • DN 150 (4″): 5,000 l/min to 20,000 l/min
  • Measurement accuracy approx. 1 – 1.5% (within measurement ranges)
  • Calibration button
  • Flow display in l/min or GPM (preset on order), graphic display
  • Flow display in m³/h or m³, graphic display
  • Pressure display in bar or psi (preset on order)
  • Power supply Lithium-Ion battery 3.7 V 1,800 mAh, with mains charger
  • Bluetooth accessory to be ordered separately; RS485 / RS232 data transmission, cable
  • Bluetooth version 2.1
  • Optional car cigarette lighter charger
Datasheet
User Manual

 

Portable measuring device for rapid performance testing of above-ground and underground fire hydrants. It determines and documents static pressure, flow pressure and flow rate directly at the draw-off point – ideal for fire brigades, network operators, water utilities, municipalities and service providers.

  • Annual inspection of hydrants to ensure operability as a firefighting water source and compliance with fire-protection regulations
  • Fast on-site measurement with clear key figures (static/flow pressure, flow rate)
  • Documentation-ready for performance and condition records
  • Rugged design for field use
  • Compatible with pillar and underground hydrants; common connectors, e.g. Storz-B
  • Optional: integration of a system separator/backflow preventer in accordance with DVGW practice
  • Carrying handles and fold-out feet
Material Aluminium alloy, glass-fibre reinforced plastic
Max. operating pressure 16 bar / 230 PSI
Operating temperature 10 °C to 60 °C
Ingress protection IP 65
Flow ranges
  • DN 40 (1.5″): 100 l/min to 1,000 l/min  |  inlet and outlet Storz C/52  Part No.: 31955
  • DN 65 (2.5″): 300 l/min to 2,500 l/min  |  inlet and outlet Storz B/75  Part No.: 31956
  • DN 80 (3″): 500 l/min to 3,000 l/min  |  inlet and outlet Storz B/75  Part No.: 31957
  • DN 100 (4″): 1,000 l/min to 5,000 l/min  |  inlet and outlet Storz A/110  Part No.: 31958
Measuring accuracy approx. 1 – 1.5 % (within the measuring ranges)
Flow display
  • l/min or GPM (factory preset on order), graphic display
  • m³/h or m³, graphic display
Pressure display bar or psi (factory preset on order)
Power supply Lithium-ion battery 3.7 V / 1,800 mAh, with mains charger
Accessories (order separately)
  • Bluetooth 2.1
  • RS485 / RS232 data transmission
  • Car cigarette-lighter charger (optional)
  • Pressure breaker
  • Suitable flow-straightening (calming) sections for inlet and outlet

Measured variables

  • Static pressure: line pressure without draw-off
  • Flow pressure: pressure during draw-off
  • Flow rate (l/min): delivery rate of the hydrant at a defined pressure
  • Minimum residual pressure: verification value for assessing network security

Standards & practical reference

  • DVGW W 405 / W 392: Provision of firefighting water via the drinking-water network (planning / fundamentals) and test intervals
  • DVGW W 405-B1: Draw-off by the fire brigade incl. requirements for drinking-water protection (system separator / backflow prevention)
  • DIN EN 14384 / DIN EN 14339: Product standards for pillar and underground hydrants (requirements / tests)
  • DIN 14462: Planning, operation and inspection of non-public firefighting water systems (e.g. in buildings) | annual testing and documentation requirement

Note: The device is intended for measurement and documentation; evaluation is based on the above standards and/or local utility requirements.

Category Flow rate Simultaneous operation Min. flow pressure Max. flow pressure Max. static pressure
Wall hydrant S 24 l/min 2 2 bar 8 bar 12 bar
Wall hydrant F 100 l/min 3 3 bar 8 bar 12 bar
Wall hydrant F 200 l/min 3 4.5 bar 8 bar 12 bar
Pillar hydrant DN80 800 l/min According to fire-protection concept 8 bar 12 bar
Pillar hydrant DN100 1,600 l/min According to fire-protection concept 1.5 bar 8 bar 12 bar
Underground hydrant DN80 800 l/min 8 bar 12 bar








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Hydrant test meter (portable)

    • Material • Aluminum alloy • fiberglass-reinforced plastic
    • Maximum working pressure 16 bar / 230 PSI
    • Operating temperature 10°C to 60°C
    • Water splash protection IP 65
    • Flow ranges • DN 40 (1.5″): 100 l/min to 1,000 l/min • DN 65 (2.5″): 300 l/min to 2,500 l/min • DN 80 (3″): 500 l/min to 3,000 l/min • DN 100 (4″): 1,000 l/min to 5,000 l/min • DN 150 (4″): 5,000 l/min to 20,000 l/min
    • Measurement accuracy approx. 1 – 1.5% (within measurement ranges)
    • Calibration button
    • Flow display in l/min or GPM (preset on order), graphic display
    • Flow display in m³/h or m³, graphic display
    • Pressure display in bar or psi (preset on order)
    • Power supply Lithium-Ion battery 3.7 V 1,800 mAh, with mains charger
    • Bluetooth accessory to be ordered separately; RS485 / RS232 data transmission, cable
    • Bluetooth version 2.1
    • Optional car cigarette lighter charger
    Datasheet
    User Manual

     

    Portable measuring device for rapid performance testing of above-ground and underground fire hydrants. It determines and documents static pressure, flow pressure and flow rate directly at the draw-off point – ideal for fire brigades, network operators, water utilities, municipalities and service providers.

    • Annual inspection of hydrants to ensure operability as a firefighting water source and compliance with fire-protection regulations
    • Fast on-site measurement with clear key figures (static/flow pressure, flow rate)
    • Documentation-ready for performance and condition records
    • Rugged design for field use
    • Compatible with pillar and underground hydrants; common connectors, e.g. Storz-B
    • Optional: integration of a system separator/backflow preventer in accordance with DVGW practice
    • Carrying handles and fold-out feet
    Material Aluminium alloy, glass-fibre reinforced plastic
    Max. operating pressure 16 bar / 230 PSI
    Operating temperature 10 °C to 60 °C
    Ingress protection IP 65
    Flow ranges
    • DN 40 (1.5″): 100 l/min to 1,000 l/min  |  inlet and outlet Storz C/52  Part No.: 31955
    • DN 65 (2.5″): 300 l/min to 2,500 l/min  |  inlet and outlet Storz B/75  Part No.: 31956
    • DN 80 (3″): 500 l/min to 3,000 l/min  |  inlet and outlet Storz B/75  Part No.: 31957
    • DN 100 (4″): 1,000 l/min to 5,000 l/min  |  inlet and outlet Storz A/110  Part No.: 31958
    Measuring accuracy approx. 1 – 1.5 % (within the measuring ranges)
    Flow display
    • l/min or GPM (factory preset on order), graphic display
    • m³/h or m³, graphic display
    Pressure display bar or psi (factory preset on order)
    Power supply Lithium-ion battery 3.7 V / 1,800 mAh, with mains charger
    Accessories (order separately)
    • Bluetooth 2.1
    • RS485 / RS232 data transmission
    • Car cigarette-lighter charger (optional)
    • Pressure breaker
    • Suitable flow-straightening (calming) sections for inlet and outlet

    Measured variables

    • Static pressure: line pressure without draw-off
    • Flow pressure: pressure during draw-off
    • Flow rate (l/min): delivery rate of the hydrant at a defined pressure
    • Minimum residual pressure: verification value for assessing network security

    Standards & practical reference

    • DVGW W 405 / W 392: Provision of firefighting water via the drinking-water network (planning / fundamentals) and test intervals
    • DVGW W 405-B1: Draw-off by the fire brigade incl. requirements for drinking-water protection (system separator / backflow prevention)
    • DIN EN 14384 / DIN EN 14339: Product standards for pillar and underground hydrants (requirements / tests)
    • DIN 14462: Planning, operation and inspection of non-public firefighting water systems (e.g. in buildings) | annual testing and documentation requirement

    Note: The device is intended for measurement and documentation; evaluation is based on the above standards and/or local utility requirements.

    Category Flow rate Simultaneous operation Min. flow pressure Max. flow pressure Max. static pressure
    Wall hydrant S 24 l/min 2 2 bar 8 bar 12 bar
    Wall hydrant F 100 l/min 3 3 bar 8 bar 12 bar
    Wall hydrant F 200 l/min 3 4.5 bar 8 bar 12 bar
    Pillar hydrant DN80 800 l/min According to fire-protection concept 8 bar 12 bar
    Pillar hydrant DN100 1,600 l/min According to fire-protection concept 1.5 bar 8 bar 12 bar
    Underground hydrant DN80 800 l/min 8 bar 12 bar








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.