PT18-10 MK2 Test Set


PT18-10 Mk2 designed for safe cable and jointing systems testing, with variable output voltage and automatic load discharge system.

  • ±18kVdc output voltage
  • 10mA output capability
  • Both voltage and current metered on HV outputs
  • Automatic earth system for dumping capacitive loads
  • HV output plug & socket system
  • Key operated supply switch to prevent unauthorised operation
  • Zero-volt interlock
  • Visual indication of test piece failure
  • Automatic mains voltage selection
Datasheet
User Manual

The PT18-10 Mk2 Test Set conducts tests on installed cable and jointing systems. It offers a variable output voltage of up to ±18kV DC and a maximum charging capability of 10mA. Equipped with a zero-volt interlock, this 18kV 10mA DC tester ensures safety. It incorporates an automatic load discharge system that safely discharges the cable under test upon switching off or in case of a breakdown.

The internal dumping system discharges a maximum of 2.5kJ on each output, equivalent to 10µF at 18kV. In the event of a test object failure, the overload circuit automatically switches off the output voltage and grounds the output through the internal discharge circuit. The PT18-10 Mk2 includes a DP20 discharge probe as a standard feature, enabling safe discharge of higher load capacitances.

Featuring an internal fail-safe automatic discharge system, the PT18-10 Mk2 DC Test Set supports a maximum discharge voltage of 20kV DC, highest discharge energy of 2.5kJ, highest discharge capacitance of 10μF, and a maximum of 4 discharges per hour. Two large, linear, analogue instruments marked 0-20kV precisely measure the output voltage. Additionally, two analogue instruments with a 0-10 scale accurately measure the current. The high voltage output incorporates a high-quality plug and socket system for easy cable replacement. Plastic covers provide protection to the plugs during transit, and the screened 5-meter long high voltage output cables feature large clips as terminations.

Furthermore, the PT18-10 Mk2 unit introduces automatic 115/230V mains voltage selection for added convenience. It comes with a padded bag to ensure maximum transit protection.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    PT18-10 MK2 Test Set

    PT18-10 Mk2 designed for safe cable and jointing systems testing, with variable output voltage and automatic load discharge system.

    • ±18kVdc output voltage
    • 10mA output capability
    • Both voltage and current metered on HV outputs
    • Automatic earth system for dumping capacitive loads
    • HV output plug & socket system
    • Key operated supply switch to prevent unauthorised operation
    • Zero-volt interlock
    • Visual indication of test piece failure
    • Automatic mains voltage selection
    Datasheet
    User Manual

    The PT18-10 Mk2 Test Set conducts tests on installed cable and jointing systems. It offers a variable output voltage of up to ±18kV DC and a maximum charging capability of 10mA. Equipped with a zero-volt interlock, this 18kV 10mA DC tester ensures safety. It incorporates an automatic load discharge system that safely discharges the cable under test upon switching off or in case of a breakdown.

    The internal dumping system discharges a maximum of 2.5kJ on each output, equivalent to 10µF at 18kV. In the event of a test object failure, the overload circuit automatically switches off the output voltage and grounds the output through the internal discharge circuit. The PT18-10 Mk2 includes a DP20 discharge probe as a standard feature, enabling safe discharge of higher load capacitances.

    Featuring an internal fail-safe automatic discharge system, the PT18-10 Mk2 DC Test Set supports a maximum discharge voltage of 20kV DC, highest discharge energy of 2.5kJ, highest discharge capacitance of 10μF, and a maximum of 4 discharges per hour. Two large, linear, analogue instruments marked 0-20kV precisely measure the output voltage. Additionally, two analogue instruments with a 0-10 scale accurately measure the current. The high voltage output incorporates a high-quality plug and socket system for easy cable replacement. Plastic covers provide protection to the plugs during transit, and the screened 5-meter long high voltage output cables feature large clips as terminations.

    Furthermore, the PT18-10 Mk2 unit introduces automatic 115/230V mains voltage selection for added convenience. It comes with a padded bag to ensure maximum transit protection.