Vacuum pressure switch VCMV301, -250…+100 mbar, adjustable switching differential 30…200 mbar, max. pressure 1,5 bar | FEMA Pressure Switch


  • Setting range: -250…+100 mbar
  • Switching differential: 30…200 mbar
  • Maximum permissible pressure: 1,5 bar
  • Pressure sensor materials: metal bellows made of CuZn; sensor housing made of CuZn

Datasheet

FEMA vacuum pressure switches detect the pressure difference relative to atmospheric pressure. All switching pressure ranges and scale markings on the switching devices therefore refer to the pressure difference between the respective atmospheric pressure and the set switching pressure. The zero reference point on the device scale corresponds to the respective atmospheric pressure. Type VCMV301 with setting range -250…+100 mbar, switching differential 30…200 mbar and maximum permissible pressure 1,5 bar.

The FEMA vacuum pressure switch VCMV301 is suitable for detecting pressure differences relative to atmospheric pressure. The setting range is -250…+100 mbar. The switching differential is adjustable and 30…200 mbar. The maximum permissible pressure is 1,5 bar. The pressure sensor materials are metal bellows made of CuZn; sensor housing made of CuZn. The zero reference point on the device scale corresponds to the respective atmospheric pressure.

Technical data
Pressure connection: external G 1/2 pressure gauge connection according to DIN 16288 and internal G 1/4 thread according to ISO 228 Part 1
Switching device: robust housing 200 made of seawater-resistant die-cast aluminium GD Al Si 12
Degree of protection: IP54 in vertical mounting position
Pressure sensor materials: VNM111 and VNM301 metal bellows made of 1.4571, sensor housing made of 1.4104; VCM095, VCM101 and VCM301 metal bellows made of CuZn, sensor housing made of CuZn; VCM4156 Perbunan diaphragm, sensor housing made of 1.4301
Mounting position: vertically upwards and horizontal
Ambient temperature at the switching device: -25…+70 °C
Max. media temperature: the maximum media temperature at the pressure sensor must not exceed the permissible ambient temperature at the switching device. Short-term temperatures up to 85 °C are permissible. Higher media temperatures are possible if suitable measures, such as a siphon, ensure the above limit values at the switching device.
Mounting: directly on the pressure line pressure gauge connection or on a flat surface with two screws, 4 mm diameter
Switching pressure: externally adjustable with a screwdriver
Switching differential: adjustable
Contact arrangement: single-pole changeover contact
Switching capacity normal: 250 V AC resistive 8 A, 250 V AC inductive 5 A, 250 V DC resistive 0.3 A, 24 V DC resistive 8 A
Setting range: -250…+100 mbar
Switching differential: 30…200 mbar
Maximum permissible pressure: 1,5 bar
Pressure sensor materials for type VCMV301: metal bellows made of CuZn; sensor housing made of CuZn
Dimensional drawing: 1 + 15

Applications
Detection of pressure differences relative to atmospheric pressure. Monitoring of vacuum and pressure conditions in industrial applications. The zero reference point on the device scale corresponds to the respective atmospheric pressure.

Produktname

VCMV301





Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Vacuum pressure switch VCMV301, -250…+100 mbar, adjustable switching differential 30…200 mbar, max. pressure 1,5 bar | FEMA Pressure Switch

    • Setting range: -250…+100 mbar
    • Switching differential: 30…200 mbar
    • Maximum permissible pressure: 1,5 bar
    • Pressure sensor materials: metal bellows made of CuZn; sensor housing made of CuZn

    Datasheet

    FEMA vacuum pressure switches detect the pressure difference relative to atmospheric pressure. All switching pressure ranges and scale markings on the switching devices therefore refer to the pressure difference between the respective atmospheric pressure and the set switching pressure. The zero reference point on the device scale corresponds to the respective atmospheric pressure. Type VCMV301 with setting range -250…+100 mbar, switching differential 30…200 mbar and maximum permissible pressure 1,5 bar.

    The FEMA vacuum pressure switch VCMV301 is suitable for detecting pressure differences relative to atmospheric pressure. The setting range is -250…+100 mbar. The switching differential is adjustable and 30…200 mbar. The maximum permissible pressure is 1,5 bar. The pressure sensor materials are metal bellows made of CuZn; sensor housing made of CuZn. The zero reference point on the device scale corresponds to the respective atmospheric pressure.

    Technical data
    Pressure connection: external G 1/2 pressure gauge connection according to DIN 16288 and internal G 1/4 thread according to ISO 228 Part 1
    Switching device: robust housing 200 made of seawater-resistant die-cast aluminium GD Al Si 12
    Degree of protection: IP54 in vertical mounting position
    Pressure sensor materials: VNM111 and VNM301 metal bellows made of 1.4571, sensor housing made of 1.4104; VCM095, VCM101 and VCM301 metal bellows made of CuZn, sensor housing made of CuZn; VCM4156 Perbunan diaphragm, sensor housing made of 1.4301
    Mounting position: vertically upwards and horizontal
    Ambient temperature at the switching device: -25…+70 °C
    Max. media temperature: the maximum media temperature at the pressure sensor must not exceed the permissible ambient temperature at the switching device. Short-term temperatures up to 85 °C are permissible. Higher media temperatures are possible if suitable measures, such as a siphon, ensure the above limit values at the switching device.
    Mounting: directly on the pressure line pressure gauge connection or on a flat surface with two screws, 4 mm diameter
    Switching pressure: externally adjustable with a screwdriver
    Switching differential: adjustable
    Contact arrangement: single-pole changeover contact
    Switching capacity normal: 250 V AC resistive 8 A, 250 V AC inductive 5 A, 250 V DC resistive 0.3 A, 24 V DC resistive 8 A
    Setting range: -250…+100 mbar
    Switching differential: 30…200 mbar
    Maximum permissible pressure: 1,5 bar
    Pressure sensor materials for type VCMV301: metal bellows made of CuZn; sensor housing made of CuZn
    Dimensional drawing: 1 + 15

    Applications
    Detection of pressure differences relative to atmospheric pressure. Monitoring of vacuum and pressure conditions in industrial applications. The zero reference point on the device scale corresponds to the respective atmospheric pressure.