M75 Installation tester for safety tests according to IEC/EN61557-1 with TRMS multimeter functions and test of cable mapping on lan RJ-45 networks


Device for safety tests according to IEC/EN61557-1 with TRMS multimeter functions and test of cable mapping on lan RJ-45 networks.
M75 is the mobile device par excellence! HT suggests operators who mainly work on private installations to ALWAYS have M75 at hand. Here’s the reason why: it is very easy to use, very small in size and it fully automatically carries out all necessary tests to establish COMPLIANCE (and hence ensure SAFETY) of a private electric system.
ALWAYS using it before starting working on an already existing system the operator does not know well and ALWAYS using it at the end of the job will guarantee the necessary safety to both operators and users of the electric systems! Thanks to its small size, this device offers many operating opportunities. M75 is used for testing the safety of electric systems, so for measuring overall earth resistance, testing RCDs type A and AC, insulation and continuity. In order to make it versatile and fully functional for any kind of end user, the device has been provided with the innovative AUTO: function: by selecting this function and only setting the value of RCD current, M75, connected to a power outlet, carries out tests of overall earth resistance, RCD tests and insulation tests in a sequence. At the end of the test, the device shows all results with the indication of compliance or non-compliance with the standards with simple symbols OK or NOT OK. This innovative product also offers the following functions: TRMS multimeter for AC/DC voltage, AC/DC current (with external clamp), Resistance measurement, Test on LAN network cables, Test of phase sequence with a single lead.

Datasheet
Functions
AUTO test (Non-trip ground resistance, RCD, Insulation) in sequence  
TRMS  
Insulation with voltage 50, 100, 250, 500, 1000VDC 250V, 500V
Continuity of protective circuit with 200mA  
Tripping time and current of RCDs A=30mA AC=300mA only general
Non-trip earth resistance  
Contact voltage  
Phase sequence  
Leakage current with optional clamp meter  
Protection category CAT III 550V
DC/AC TRMS voltage and current, Frequency, Resistance, Continuity with buzzer  
Size (LxWx H) (mm) 240x100x45
Weight in grams (batteries included) 450
 
Guidelines
  •  CEI 64-8
  •  CEI 64-8 612.2
  •  CEI 64-8 612.3 .4 .5
  •  CE MARK
  •  EMC 2014/30/EU
  •  EMC: IEC/EN61326
  •  EN61008
  •  IEC/EN61010-1
  •  IEC/EN61557-1
  •  IEC/EN61557-2
  •  IEC/EN61557-3
  •  IEC/EN61557-4
  •  IEC/EN61557-6
  •  IEC/EN61557-7
  •  LVD 2014/35/EU
  •  TIA 568B
  •  UNE20460








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    M75 Installation tester for safety tests according to IEC/EN61557-1 with TRMS multimeter functions and test of cable mapping on lan RJ-45 networks

    Device for safety tests according to IEC/EN61557-1 with TRMS multimeter functions and test of cable mapping on lan RJ-45 networks.
    M75 is the mobile device par excellence! HT suggests operators who mainly work on private installations to ALWAYS have M75 at hand. Here’s the reason why: it is very easy to use, very small in size and it fully automatically carries out all necessary tests to establish COMPLIANCE (and hence ensure SAFETY) of a private electric system.
    ALWAYS using it before starting working on an already existing system the operator does not know well and ALWAYS using it at the end of the job will guarantee the necessary safety to both operators and users of the electric systems! Thanks to its small size, this device offers many operating opportunities. M75 is used for testing the safety of electric systems, so for measuring overall earth resistance, testing RCDs type A and AC, insulation and continuity. In order to make it versatile and fully functional for any kind of end user, the device has been provided with the innovative AUTO: function: by selecting this function and only setting the value of RCD current, M75, connected to a power outlet, carries out tests of overall earth resistance, RCD tests and insulation tests in a sequence. At the end of the test, the device shows all results with the indication of compliance or non-compliance with the standards with simple symbols OK or NOT OK. This innovative product also offers the following functions: TRMS multimeter for AC/DC voltage, AC/DC current (with external clamp), Resistance measurement, Test on LAN network cables, Test of phase sequence with a single lead.

    Datasheet
    Functions
    AUTO test (Non-trip ground resistance, RCD, Insulation) in sequence  
    TRMS  
    Insulation with voltage 50, 100, 250, 500, 1000VDC 250V, 500V
    Continuity of protective circuit with 200mA  
    Tripping time and current of RCDs A=30mA AC=300mA only general
    Non-trip earth resistance  
    Contact voltage  
    Phase sequence  
    Leakage current with optional clamp meter  
    Protection category CAT III 550V
    DC/AC TRMS voltage and current, Frequency, Resistance, Continuity with buzzer  
    Size (LxWx H) (mm) 240x100x45
    Weight in grams (batteries included) 450
     
    Guidelines
    •  CEI 64-8
    •  CEI 64-8 612.2
    •  CEI 64-8 612.3 .4 .5
    •  CE MARK
    •  EMC 2014/30/EU
    •  EMC: IEC/EN61326
    •  EN61008
    •  IEC/EN61010-1
    •  IEC/EN61557-1
    •  IEC/EN61557-2
    •  IEC/EN61557-3
    •  IEC/EN61557-4
    •  IEC/EN61557-6
    •  IEC/EN61557-7
    •  LVD 2014/35/EU
    •  TIA 568B
    •  UNE20460








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.