C.A 6131 multifunction tester


  • Earth measurement by loop methods
  • Continuity measurement at 0.2A
  • Insulation testing
  • RCD testing: current and trip time
Datasheet
User Manual

Complete and lightweight, the C.A 6131 multifunction tester can be used to perform all the measurements and tests needed by certification organizations and maintenance teams to qualify an electrical installation.

Ergonomics

The C.A 6131 is simple to use. On the front panel, each key corresponds to a function. It is designed for simplified use in all conditions:

  • Stand for positioning on a bench or table
  • 4-point strap for effortless hands-free use
  • Backlit screen for easy reading, even when the lighting is insufficient
  • Terminal strip with explicit markings (L, N, PE, +, com) to prevent connection errors
  • Remote-control probe for starting tests remotely
  • A three-pole cable for direct measurements on 2P + E sockets Measurements

The C.A 6131 can be used for voltage, continuity, resistance, insulation and loop measurements. The current can be measured with an external clamp. It is possible to test type A & AC RCDs in ramp or pulse mode. The C.A 6131 also checks the phase rotation. For greater efficiency, the C.A 6131 provides an immediate visual indication of the test result (OK/NOK).

Main technical specifications: 

  • Voltage measurement: 550 VAC / 800 VDC 
  • Continuity at 200 mA,
  • Resistance from 1 to 99.99 kΩ 
  • Insulation: 250V and 500V test voltage, measurement up to 999 MΩ 
  • Zs (Z L-PE) loop without tripping: 1 to 2,000 Ω, calculation of Ik 
  • Zs (Z L-PE) high-current loop with tripping and Zi (Z L-N or Z L-L), from 0.1 to 400 Ω, calculation of Ik 
  • Type AC & A RCDs: 30mA, 100mA, 300 mA, 500 mA, 650 mA 
  • RCD in pulse mode: tripping time 
  • RCD in ramp mode (30 mA): tripping current 
  • Phase rotation: 45 to 550V; 45 to 65 Hz








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    C.A 6131 multifunction tester

    • Earth measurement by loop methods
    • Continuity measurement at 0.2A
    • Insulation testing
    • RCD testing: current and trip time
    Datasheet
    User Manual

    Complete and lightweight, the C.A 6131 multifunction tester can be used to perform all the measurements and tests needed by certification organizations and maintenance teams to qualify an electrical installation.

    Ergonomics

    The C.A 6131 is simple to use. On the front panel, each key corresponds to a function. It is designed for simplified use in all conditions:

    • Stand for positioning on a bench or table
    • 4-point strap for effortless hands-free use
    • Backlit screen for easy reading, even when the lighting is insufficient
    • Terminal strip with explicit markings (L, N, PE, +, com) to prevent connection errors
    • Remote-control probe for starting tests remotely
    • A three-pole cable for direct measurements on 2P + E sockets Measurements

    The C.A 6131 can be used for voltage, continuity, resistance, insulation and loop measurements. The current can be measured with an external clamp. It is possible to test type A & AC RCDs in ramp or pulse mode. The C.A 6131 also checks the phase rotation. For greater efficiency, the C.A 6131 provides an immediate visual indication of the test result (OK/NOK).

    Main technical specifications: 

    • Voltage measurement: 550 VAC / 800 VDC 
    • Continuity at 200 mA,
    • Resistance from 1 to 99.99 kΩ 
    • Insulation: 250V and 500V test voltage, measurement up to 999 MΩ 
    • Zs (Z L-PE) loop without tripping: 1 to 2,000 Ω, calculation of Ik 
    • Zs (Z L-PE) high-current loop with tripping and Zi (Z L-N or Z L-L), from 0.1 to 400 Ω, calculation of Ik 
    • Type AC & A RCDs: 30mA, 100mA, 300 mA, 500 mA, 650 mA 
    • RCD in pulse mode: tripping time 
    • RCD in ramp mode (30 mA): tripping current 
    • Phase rotation: 45 to 550V; 45 to 65 Hz








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.