HySense FO110 – Force Sensor Based on the Bending Beam Principle


  • Measurement principle: bending beam
  • Output signal 4 … 20 mA
Data sheet
  • Measurement principle: bending beam
  • Output signal 4 … 20 mA
  • Electrical connection: 5-pin device connector, M16 x 0.75
  • Protection class (EN 60529 / IEC 529) IP 65
  • Housing material: steel
  • Signal type: three-wire
  • Supply voltage Ub 10 … 24 VDC
  • Current consumption max. 40 mA
  • Error limit < 0.5 % of full scale
  • Temperature error nominal point < ± 0.04 % of full scale / K
  • Temperature error output signal < ± 0.04 % of measuring range / K
  • Non-linearity < ± 0.15 % of full scale
  • Hysteresis max. 0.1 % of full scale
  • Calibration in N
  • Calibration tolerance < 0.25 % of full scale
  • Ambient temperature -15 … +85 °C
  • Storage temperature -15 … +85 °C








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    HySense FO110 – Force Sensor Based on the Bending Beam Principle

    • Measurement principle: bending beam
    • Output signal 4 … 20 mA
    Data sheet
    • Measurement principle: bending beam
    • Output signal 4 … 20 mA
    • Electrical connection: 5-pin device connector, M16 x 0.75
    • Protection class (EN 60529 / IEC 529) IP 65
    • Housing material: steel
    • Signal type: three-wire
    • Supply voltage Ub 10 … 24 VDC
    • Current consumption max. 40 mA
    • Error limit < 0.5 % of full scale
    • Temperature error nominal point < ± 0.04 % of full scale / K
    • Temperature error output signal < ± 0.04 % of measuring range / K
    • Non-linearity < ± 0.15 % of full scale
    • Hysteresis max. 0.1 % of full scale
    • Calibration in N
    • Calibration tolerance < 0.25 % of full scale
    • Ambient temperature -15 … +85 °C
    • Storage temperature -15 … +85 °C








    Technical advice: 03303 / 50 40 66