| Input |
004: 0.04 bar / 0.41 mH₂O, 006: 0.06 bar / 0.61 mH₂O, 010: 0.10 bar / 1.02 mH₂O, 016: 0.16 bar / 1.63 mH₂O, 025: 0.25 bar² / 2.55 mH₂O, 040: 0.40 bar / 4.08 mH₂O, 060: 0.60 bar / 6.12 mH₂O, 100: 1.0 bar / 10.2 mH₂O, 160: 1.6 bar / 16.3 mH₂O, 250: 2.5 bar / 25.5 mH₂O, 400: 4.0 bar / 40.8 mH₂O, 600: 6.0 bar / 61.2 mH₂O, 100: 10 bar / 102 mH₂O, 160: 16 bar / 163 mH₂O, 200: 20 bar / 204 mH₂O, 999: customer (on request)
|
| Output |
1: 4 … 20 mA / 2-wire, 3: 0 … 10 V / 3-wire, E: intrinsic safety 4 … 20 mA / 2-wire, 9: customer (on request)
|
| Accuracy |
3: 0.35 % FSO (standard), 2: 0.25 % FSO (for pₙ ≥ 0.6 bar), 9: customer (on request)
|
| Electrical connection |
1: male and female plug ISO 4400, 2: male plug Binder series 723 (5-pin), M: male plug M12x1 (4-pin) / metal, T: cable outlet with PVC cable (IP67) (Standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 … 70 °C); others on request), R: cable outlet,, T: cable with ventilation tube (IP68) (PVC cable, cable with ventilation tube available in different types and lengths), 8: compact field housing, 5: stainless steel 1.4301 (304) (Not possible in combination with compact field housing), 9: customer (on request)
|
| Mechanical connection |
1: G 1/2" DIN 3852, 2: G 1/2" EN 837, 3: Clamp DN 32 (DIN 32676), 6: Clamp DN 50 (DIN 32676), 7: dairy pipe DN 50 (DIN 11851) (Not possible in combination with compact field housing), M: dairy pipe DN 50 (DIN 11851)(Not possible in combination with compact field housing) with nut, F: flange DN 25 / PN 40 (DIN 2501), F2: flange DN 40 / PN 40 (DIN 2501), F3: flange DN 50 / PN 40 (DIN 2501), F4: flange DN 80 / PN 16 (DIN 2501), 9: customer (on request)
|
| Seal |
1: FKM, 3: EPDM, 9: customer (on request)
|
| Pressure port |
1: stainless steel 1.4404 (316L), 9: customer (on request)
|
| Diaphragm |
C: ceramics Al₂O₃ 99.9 %, 9: customer (on request)
|