DPR 100 A/B
100 mm strip chart recorder / multipoint printer
| Type | Microprocessor-controlled 100 mm strip chart recorder with high functionality |
|---|---|
| Model | DPR 100 A/B |
| Versions | DPR 100 A and DPR 100 B |
| DPR 100 A | 1- to 3-pen line recorder for continuous recording |
| DPR 100 B | 1- or 6-channel multipoint printer |
| Design | Cost-effective microprocessor-controlled strip chart recorder designed for high quality, robustness and flexibility |
| Line recorder channels | 1-pen, 2-pen or 3-pen line recorder |
| Multipoint printer channels | 1- or 6-channel multipoint printer |
| Chart width | 100 mm according to DIN 16230 |
| Accuracy class | 0.25 % over the entire scale range, according to IEC 873 |
| Display | Analogue displays with a wide selection of measuring ranges and scales |
| Inputs | Fully configurable universal inputs for thermocouples, resistance thermometers, mV, V and mA |
| Chart paper | Roll or fanfold paper |
| Documentation | Documentation of date, time, measuring range, engineering unit, chart speed, identification number, alarm/limit values and events |
| Alarm/limit relays | Up to 6 alarm/limit relay outputs; line recorder: 2 limits per fibre pen; multipoint printer: 1 limit per channel |
| Binary inputs | Up to 2 binary inputs for event recording, print interruption and chart speed change |
| Chart speed line recorder | 2 configurable chart speeds: 10 to 600 mm/h |
| Chart speed multipoint printer | 10 to 1500 mm/h |
| Device configuration | Easy device configuration via plain-text messages printed on the chart paper |
| PC configuration | Full device configuration via configuration software using PC connection through the front socket |
| Device calibration | Device calibration for checking sensor, lower and upper measuring range settings; operating interval up to 60 °C |
| Supply voltage | Universal power supply: 85 to 264 V AC, 50/60 Hz, 24 or 48 V AC/DC |
| Front protection | IP54 according to IEC 529 |
| Dimensions | 144 × 144 mm according to DIN 43700 / 43718 |
| Installation depth | 245 mm behind panel |
| Options | Chart paper illumination, door lock, rear terminal cover, 24 V DC max. 75 mA, temperature compensation, 2 binary inputs, 2 or 6 alarm/limit outputs, portable version, scratch-resistant front window, UL/CSA approval |

Datasheet