For monitoring and controlling pressures in Ex-applications in devices of the chemical industry and in the process engineering as well as wherever the pressure of aggressive liquids and gases has to be monitored. Degree of Ex-protection: Ex II 2G Ex d e IIC T6 Gb and Ex II 1/2D Ex ta/tb IIIC T80 oC Da/Db
| Kind of pressure |
overpressure, relative |
| Pressure connection |
internal thread G1/4, external thread G1/2 |
| Electrical connection |
terminal connection M16x1,5 |
| Protection class |
IP65 |
| Housing material |
rugged housing of seawater resistant aluminium die casting GD Al Si 12 |
| Media temp. |
-20 … 60 oC |
| Media temp. limit |
Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap, see Accessories for Pressure Switches / Transmitters) |
| Ambient temperature |
-20 … 60 oC |
| Ambient temp. limit |
at temperatures below 0 oC, ensure that no water condensation can arise in the sensor and in the switching device |
| Switch function/capacity |
SPDT Microswitch 250 Vac; capacity 2 A inductive, 3 A resistive |
| Certificates |
| • |
IBExU12ATEX1040 according ATEX 2014/34/EU |
| • |
IECEx IBE 14.0077 |
| • |
SIL2 according IEC 61508-2 |
|
| Pressure adjustment range |
Switching differential |
Max. pressure |
Type |
| bar |
bar |
bar |
|
| 0.04 … 0.25 |
0.03 |
6 |
EX-DNS025 |
| 0.1 … 0.6 |
0.04 |
6 |
EX-DNS06 |
| 0.2 … 1.6 |
0.06 |
6 |
EX-DNS1 |
| 0.2 … 2.5 |
0.1 |
16 |
EX-DNS3 |
| 0.5 … 6 |
0.15 |
16 |
EX-DNS6 |
| 1 … 10 |
0.3 |
16 |
EX-DNS10 |
| 3 … 16 |
0.5 |
25 |
EX-DNS16 |