Our new tool for dew point measurement resp. pressure dew point measurement in potentially explosive atmospheres. The IFA 515 Ex can be used in many non-aggressive gases.
Typical applications: Air / Compressed air, Argon, Nitrogen, Biogas, Natural gas, Hydrogen, etc.
Our dew point sensor IFA 515 Ex complies with the following industry approvals:
- ATEX II 2G Ex ib IIC T4 Gb Zone 1, gas, intrinsically safe, Temp. 135°C
- ATEX II 2D Ex ib IIIC T80°C Db Zone 21, dust, intrinsically safe, Temp. 80°C
Please note: The IFA 515 Ex may only be used in connection with approved Ex-rated power supplies or safety barriers or galvanic separating elements. Thereby the following maximum values must be observed:
- U2 = 28 V max.
- I2 = 93 mA max.
- P2 = 0,65 W max.