MTX 3297Ex Intrinsically Safe Digital Multimeter


  • Certified ATEX/IEC Ex IIC (gas) 0, 1, 2, IIIC (dust) 20, 21, 22 and Mines M1
  • TRMS AC+DC acquisition
  • 60,000-count display resolution
  • 100 kHz bandwidth
  • 1µV resolution for voltage and 0.01 µA resolution for current
  • Large 5.7” backlit digital screen
  • Secure terminal strip with clear indication of the connections to avoid any risk of error

Out of operation / Non-Ex:

  • 1000 V CAT III / 600 V CAT IV
  • IP67

User Manual
Videos

The MTX 3297Ex is a digital multimeter which complies with European directive 2014/34/UE on explosive (Ex) atmospheres. The MTX 3297Ex fulfils all the requirements related to the operating constraints in sectors such as:

  • the oil industry
  • the chemicals industry
  • the pharmaceutical industry
  • the cosmetics industry
  • mining, etc.

It meets the needs of electrical maintenance teams: tests and troubleshooting inside and outside any hazardous zones with explosive atmospheres, without sacrificing compliance or measurement performance.

Usable outside Ex zones (out of operation), whatever the industrial activity, the MTX 3297Ex is a communicating instrument offering optimum industrial performance. It is possible to record the measurements on a PC by means of the SX-DMM software available for download from our website free of charge.

Measurements

  • Voltage
  • Current
  • Resistance (continuity, semiconductor junction)
  • Capacitance
  • Frequency (duty cycle/pulse width)
  • Temperature
  • AC/DC current measurement with selection of the I/O ratio

 

Functions

Specific measurements:

  • VLowZ low-impedance voltage measurement in the presence of “stray” disturbance voltages.
  • Low-pass filter for measuring the PWM signal

Functions to help with analysis and diagnostics

  • Min, MAX, Peak+ and Peak- functions
  • ∆X differential and ∆X/X relative functions
  • Duty cycle and pulse width

Additional specifications

  • Designed and manufactured in France
  • 3-year warranty
TECHNICAL DATA
Voltage DC, AC and AC+DC
V DC Measuring range 0,001 mV to 1000,0 V DC
Uncertainty 0,05 % + 25 digits
V AC, V AC+DC Measuring range 0,001 mV to 1000,0 V AC or AC+DC
Uncertainty AC, AC+DC / Bandwidth 0,5 % + 50 digits / 300 Hz
Vlowz Measuring range 0,001 mV to 1000,0 V AC+DC
Uncertainty / Bandwidth 0,5 % + 25 digits / 300 Hz
Ex zone measuring range 0,1 mV to 600 V AC+DC
Current DC, AC and AC+DC (protected by fuse)
A DC Measuring range 0,01 µA to 10,00 A DC (max. 20 A/30 s)
Uncertainty 0,8 % + 5 digits
A AC, A AC+DC Measuring range 0,01 µA to 10,00 A AC or AC+DC (max. 20 A/30 s)
Uncertainty / Bandwidth 1,0 % + 10 digits / 50 Hz
Ex zone measuring range 0,1 µA to 5,0 A AC+DC
With external current clamp Up to 6000 A depending on type, transformer ratio 1, 10, 100, 1000 mV/A
Frequency
Hz Measuring range 10,00 Hz to 200,0 kHz (in V), 20,00 kHz (in A)
Uncertainty 0,1 % + 5 digits
Resistance and continuity test, diode test
Ω Measuring range 0,001 Ω to 60,00 MΩ
Uncertainty 0,9 % + 10 digits
Continuity test Measuring range Acoustic signal < 30 Ω ± (5 Ω)
Diode test Measuring range 3,000 V, 1 % + 30 digits
Uncertainty 1 % + 1,1 mA
Capacitance
nF/µF/mF Measuring range 0,001 nF to 60,000 mF
Uncertainty 1 % + 10 digits
Temperature PT100 / PT1000
°C/°F Measuring range -200,0 °C to + 800,0 °C
Uncertainty 0,1 % / 15 °C
Additional functions
Main measurement Conductivity
Secondary measurements Duty cycle, pulse width, ohmic power (U²/R), dBm
Functions MAX/MIN/AVG, Peak+/Peak-, relative value, differential value, relative value
PWM filter Low-pass filter 300 Hz, 4th order
General characteristics
Display Dual LCD display with 60,000 digits and 3-stage backlight
Power supply 4 ATEX-approved AA/LR6-FE batteries, operating time 150 h
Compliance outside hazardous (explosive) areas IEC 61010-2-033 1000 V CAT IV / 600 V CAT IV EN 61326-1 Class B
Degree of protection / environment IP 67* / Storage temperature -20 °C to + 60 °C, operating temperature -10 °C to + 50 °C
Dimensions Dimensions (W x D x H): 193 x 97 x 47 mm, weight: 715 g
Warranty 3 years




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    MTX 3297Ex Intrinsically Safe Digital Multimeter

    • Certified ATEX/IEC Ex IIC (gas) 0, 1, 2, IIIC (dust) 20, 21, 22 and Mines M1
    • TRMS AC+DC acquisition
    • 60,000-count display resolution
    • 100 kHz bandwidth
    • 1µV resolution for voltage and 0.01 µA resolution for current
    • Large 5.7” backlit digital screen
    • Secure terminal strip with clear indication of the connections to avoid any risk of error

    Out of operation / Non-Ex:

    • 1000 V CAT III / 600 V CAT IV
    • IP67

    User Manual
    Videos

    The MTX 3297Ex is a digital multimeter which complies with European directive 2014/34/UE on explosive (Ex) atmospheres. The MTX 3297Ex fulfils all the requirements related to the operating constraints in sectors such as:

    • the oil industry
    • the chemicals industry
    • the pharmaceutical industry
    • the cosmetics industry
    • mining, etc.

    It meets the needs of electrical maintenance teams: tests and troubleshooting inside and outside any hazardous zones with explosive atmospheres, without sacrificing compliance or measurement performance.

    Usable outside Ex zones (out of operation), whatever the industrial activity, the MTX 3297Ex is a communicating instrument offering optimum industrial performance. It is possible to record the measurements on a PC by means of the SX-DMM software available for download from our website free of charge.

    Measurements

    • Voltage
    • Current
    • Resistance (continuity, semiconductor junction)
    • Capacitance
    • Frequency (duty cycle/pulse width)
    • Temperature
    • AC/DC current measurement with selection of the I/O ratio

     

    Functions

    Specific measurements:

    • VLowZ low-impedance voltage measurement in the presence of “stray” disturbance voltages.
    • Low-pass filter for measuring the PWM signal

    Functions to help with analysis and diagnostics

    • Min, MAX, Peak+ and Peak- functions
    • ∆X differential and ∆X/X relative functions
    • Duty cycle and pulse width

    Additional specifications

    • Designed and manufactured in France
    • 3-year warranty
    TECHNICAL DATA
    Voltage DC, AC and AC+DC
    V DC Measuring range 0,001 mV to 1000,0 V DC
    Uncertainty 0,05 % + 25 digits
    V AC, V AC+DC Measuring range 0,001 mV to 1000,0 V AC or AC+DC
    Uncertainty AC, AC+DC / Bandwidth 0,5 % + 50 digits / 300 Hz
    Vlowz Measuring range 0,001 mV to 1000,0 V AC+DC
    Uncertainty / Bandwidth 0,5 % + 25 digits / 300 Hz
    Ex zone measuring range 0,1 mV to 600 V AC+DC
    Current DC, AC and AC+DC (protected by fuse)
    A DC Measuring range 0,01 µA to 10,00 A DC (max. 20 A/30 s)
    Uncertainty 0,8 % + 5 digits
    A AC, A AC+DC Measuring range 0,01 µA to 10,00 A AC or AC+DC (max. 20 A/30 s)
    Uncertainty / Bandwidth 1,0 % + 10 digits / 50 Hz
    Ex zone measuring range 0,1 µA to 5,0 A AC+DC
    With external current clamp Up to 6000 A depending on type, transformer ratio 1, 10, 100, 1000 mV/A
    Frequency
    Hz Measuring range 10,00 Hz to 200,0 kHz (in V), 20,00 kHz (in A)
    Uncertainty 0,1 % + 5 digits
    Resistance and continuity test, diode test
    Ω Measuring range 0,001 Ω to 60,00 MΩ
    Uncertainty 0,9 % + 10 digits
    Continuity test Measuring range Acoustic signal < 30 Ω ± (5 Ω)
    Diode test Measuring range 3,000 V, 1 % + 30 digits
    Uncertainty 1 % + 1,1 mA
    Capacitance
    nF/µF/mF Measuring range 0,001 nF to 60,000 mF
    Uncertainty 1 % + 10 digits
    Temperature PT100 / PT1000
    °C/°F Measuring range -200,0 °C to + 800,0 °C
    Uncertainty 0,1 % / 15 °C
    Additional functions
    Main measurement Conductivity
    Secondary measurements Duty cycle, pulse width, ohmic power (U²/R), dBm
    Functions MAX/MIN/AVG, Peak+/Peak-, relative value, differential value, relative value
    PWM filter Low-pass filter 300 Hz, 4th order
    General characteristics
    Display Dual LCD display with 60,000 digits and 3-stage backlight
    Power supply 4 ATEX-approved AA/LR6-FE batteries, operating time 150 h
    Compliance outside hazardous (explosive) areas IEC 61010-2-033 1000 V CAT IV / 600 V CAT IV EN 61326-1 Class B
    Degree of protection / environment IP 67* / Storage temperature -20 °C to + 60 °C, operating temperature -10 °C to + 50 °C
    Dimensions Dimensions (W x D x H): 193 x 97 x 47 mm, weight: 715 g
    Warranty 3 years




    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.