SOLAR300N Power Quality Analyzer for checking the efficiency of photovoltaic systems


    • New touchscreen interface
    • Verification of the efficiency of the photovoltaic system
    • Power quality Analysis with voltage Fast Transient (5µs) measurement
    Datasheet

    SOLAR300N tests the efficiency of a  single-phase and three-phase photovoltaic systems. For this kind of tests, it is necessary to guarantee simultaneity between power measurements carried out at the inverter and irradiation and temperature measurements carried out on the photovoltaic panels. HT Italia has solve this problem by creating a remote measuring device SOLAR02 which acquires the values of solar Irradiation [W/m2], panel Temperature [°C] and environmental Temperature [°C] and transfers them onto SOLAR300N, which inserts them onto the same string of power measurements an then elaborates them with the simultaneity required by the law in force.
    At the end of calculation, the indication of a positive or negative result of testing appears on the display of SOLAR300N. Beside measuring and logging the efficiency of PV systems, SOLAR300N is also a powerful power quality analyzer to perform analysis according to EN50160 (harmonics, voltage anomalies, flicker, voltage unbalance, etc.). While used as a power quality analyzer, flexible clamps HTFLEX33e can be used, while in PV analyzing flexible clamps cannot be used.

     

     

    Functions
    Single-phase/three-phase photvoltaic systems’ testing 1MPPT (3MPPT with MPP300)
    DC side efficiency of the photovoltaic field
    Use of remote unit SOLAR-02 with USB \ RF connection USB
    Measurement of irradiation with reference cell
    Temperature measurement of cell and environment
    AC/DC voltage in single-phase/three-phase systems
    AC/DC current in single-phase/three-phase systems
    Cosphi, Power Factor
    Voltage unbalance (NEG%, ZERO%)
    Active P, Reactive Q, Apparent S Power/Energy
    Voltage and current harmonics up to the 49th with THD
    Voltage anomalies (dips, peaks) with a resolution of 10ms (@ 50Hz)
    Voltage Spikes with 5µs resolution
    Electric motor starting current (INRUSH)
    Voltage flickers (Pst, Plt)
    Full analysis EN50160
    Phase sequence
    Neutral-Ground Voltage
    Neutral current
    Max number of simultaneously selectable parameters 251
    Recording with selectable integration period 1s-60m
    Indicative memory duration (in days @ PI=10min @ max number of parameters) 90
    Indication of recording duration for mains analysis
    Internal memory extension with Compact Flash card
    Default and custom recordings
    Summary table of main electric parameters
    Voltage/current waveforms
    Tables or histograms of Harmonics and THD%
    Voltage/current vector diagram
    Measuring range for photovoltaic testing 1000VAC-DC / 3000A
    Touchscreen colour display
    Internal memory capacity 15MB 90 days@ PI 10min
    USB port for data download onto Pen Drive
    Provided PC interface with software for Windows
    Power supply with rechargeable battery and battery charger
    Auto power off
    Indication of recording duration for photovoltaic testing
    Size (LxWxH) (mm) 235x165x75
    Weight in grams (batteries included) 1000
    Measurement category CAT IV 600V








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      SOLAR300N Power Quality Analyzer for checking the efficiency of photovoltaic systems

        • New touchscreen interface
        • Verification of the efficiency of the photovoltaic system
        • Power quality Analysis with voltage Fast Transient (5µs) measurement
        Datasheet

        SOLAR300N tests the efficiency of a  single-phase and three-phase photovoltaic systems. For this kind of tests, it is necessary to guarantee simultaneity between power measurements carried out at the inverter and irradiation and temperature measurements carried out on the photovoltaic panels. HT Italia has solve this problem by creating a remote measuring device SOLAR02 which acquires the values of solar Irradiation [W/m2], panel Temperature [°C] and environmental Temperature [°C] and transfers them onto SOLAR300N, which inserts them onto the same string of power measurements an then elaborates them with the simultaneity required by the law in force.
        At the end of calculation, the indication of a positive or negative result of testing appears on the display of SOLAR300N. Beside measuring and logging the efficiency of PV systems, SOLAR300N is also a powerful power quality analyzer to perform analysis according to EN50160 (harmonics, voltage anomalies, flicker, voltage unbalance, etc.). While used as a power quality analyzer, flexible clamps HTFLEX33e can be used, while in PV analyzing flexible clamps cannot be used.

         

         

        Functions
        Single-phase/three-phase photvoltaic systems’ testing 1MPPT (3MPPT with MPP300)
        DC side efficiency of the photovoltaic field
        Use of remote unit SOLAR-02 with USB \ RF connection USB
        Measurement of irradiation with reference cell
        Temperature measurement of cell and environment
        AC/DC voltage in single-phase/three-phase systems
        AC/DC current in single-phase/three-phase systems
        Cosphi, Power Factor
        Voltage unbalance (NEG%, ZERO%)
        Active P, Reactive Q, Apparent S Power/Energy
        Voltage and current harmonics up to the 49th with THD
        Voltage anomalies (dips, peaks) with a resolution of 10ms (@ 50Hz)
        Voltage Spikes with 5µs resolution
        Electric motor starting current (INRUSH)
        Voltage flickers (Pst, Plt)
        Full analysis EN50160
        Phase sequence
        Neutral-Ground Voltage
        Neutral current
        Max number of simultaneously selectable parameters 251
        Recording with selectable integration period 1s-60m
        Indicative memory duration (in days @ PI=10min @ max number of parameters) 90
        Indication of recording duration for mains analysis
        Internal memory extension with Compact Flash card
        Default and custom recordings
        Summary table of main electric parameters
        Voltage/current waveforms
        Tables or histograms of Harmonics and THD%
        Voltage/current vector diagram
        Measuring range for photovoltaic testing 1000VAC-DC / 3000A
        Touchscreen colour display
        Internal memory capacity 15MB 90 days@ PI 10min
        USB port for data download onto Pen Drive
        Provided PC interface with software for Windows
        Power supply with rechargeable battery and battery charger
        Auto power off
        Indication of recording duration for photovoltaic testing
        Size (LxWxH) (mm) 235x165x75
        Weight in grams (batteries included) 1000
        Measurement category CAT IV 600V