TAS81 Single-phase current transformer – measurement


  • Single-phase current transformers for AC current measurement
  • TAS64 and TAS81 versions for primary rated currents from 250 A to 2500 A
  • Secondary rated current selectable with 5 A or 1 A
  • Suitable for feed-through mounting with cable or busbar
  • Designed as air-insulated dry-type transformer
  • Insulation class B and rated insulation voltage of 3 kV r.m.s.
  • Robust self-extinguishing polycarbonate housing
  • Suitable for measuring and monitoring tasks in low-voltage installations
Datasheet

TAS64 / TAS81

Single-phase current transformers for measurement

Model TAS64 TAS81
Technical datasheet NT569 NT573
Reference standards EN/IEC 61869-1, 61869-2
Primary rated current Ipn 250…1600 A 400…2500 A
Rated frequency 50 Hz
Operating frequency 47…63 Hz
Thermal rated continuous current Icth 100 % Ipr
Thermal continuous current Ith < 60 Ir
Dynamic rated current 2.5 Ith
Safety factor (SF) ≤ 5
Secondary rated current Isr 5…1 A
Maximum power loss ≤ 16 W ≤ 14.5 W
Max. temperature of passing cable / busbar 125 °C
Type Dry transformer, air-insulated
Highest permissible operating voltage Um 0.72 kV r.m.s.
Rated insulation voltage 3 kV r.m.s., 50 Hz / 1 min
Insulation class B
Operating temperature -25…50 °C
Storage temperature -40…85 °C
Relative humidity ≤ 85 %
Suitable for tropical climate Yes
Primary connection Feed-through opening
Secondary connection M4 terminals with nut fastening
Material Self-extinguishing polycarbonate
Protection rating according to EN/IEC 60529 IP40 housing, IP00 terminals, IP20 with sealable terminal cover
Weight 500 g 470 g






Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    TAS81 Single-phase current transformer – measurement

    • Single-phase current transformers for AC current measurement
    • TAS64 and TAS81 versions for primary rated currents from 250 A to 2500 A
    • Secondary rated current selectable with 5 A or 1 A
    • Suitable for feed-through mounting with cable or busbar
    • Designed as air-insulated dry-type transformer
    • Insulation class B and rated insulation voltage of 3 kV r.m.s.
    • Robust self-extinguishing polycarbonate housing
    • Suitable for measuring and monitoring tasks in low-voltage installations
    Datasheet

    TAS64 / TAS81

    Single-phase current transformers for measurement

    Model TAS64 TAS81
    Technical datasheet NT569 NT573
    Reference standards EN/IEC 61869-1, 61869-2
    Primary rated current Ipn 250…1600 A 400…2500 A
    Rated frequency 50 Hz
    Operating frequency 47…63 Hz
    Thermal rated continuous current Icth 100 % Ipr
    Thermal continuous current Ith < 60 Ir
    Dynamic rated current 2.5 Ith
    Safety factor (SF) ≤ 5
    Secondary rated current Isr 5…1 A
    Maximum power loss ≤ 16 W ≤ 14.5 W
    Max. temperature of passing cable / busbar 125 °C
    Type Dry transformer, air-insulated
    Highest permissible operating voltage Um 0.72 kV r.m.s.
    Rated insulation voltage 3 kV r.m.s., 50 Hz / 1 min
    Insulation class B
    Operating temperature -25…50 °C
    Storage temperature -40…85 °C
    Relative humidity ≤ 85 %
    Suitable for tropical climate Yes
    Primary connection Feed-through opening
    Secondary connection M4 terminals with nut fastening
    Material Self-extinguishing polycarbonate
    Protection rating according to EN/IEC 60529 IP40 housing, IP00 terminals, IP20 with sealable terminal cover
    Weight 500 g 470 g






    Technical advice: 03303 / 50 40 66