Nemo D4-L – Network monitor for low voltage 4 module


  • Multifunction display for measurement acquisition in low-voltage networks
  • Suitable for single-phase networks and 3-/4-wire three-phase networks with unbalanced load
  • Three-phase network 50…450 V phase-phase, single-phase network 30…260 V
  • Current input 1 A or 5 A via external current transformers
  • Voltage input direct or via voltage transformer with adjustable transformer ratio
  • Measurement of active energy class 1 or reactive energy class 2
  • Depending on version without output, with RS485 communication or with pulse output
  • Backlit LCD display and 4-DIN-module design
Datasheet
User Manual

Nemo D4-L / D4-LCM / D4-LP

Multifunction display for low-voltage networks, 4 modules

Type Multifunction display for electrical measurement acquisition in low-voltage networks
Format 4 DIN modules
Network Single-phase network and 3-/4-wire three-phase network, unbalanced load
Three-phase network 50…450 V phase-phase
Single-phase network 30…260 V
Current input 1 A or 5 A, connection to external current transformers with adjustable CT ratio
Voltage 50…450 V phase-phase, direct or via voltage transformer with adjustable VT ratio
Measured values Active energy class 1 or reactive energy class 2
Display Backlit LCD
Output Nemo D4-L Without output
Output Nemo D4-LCM RS485 communication
Output Nemo D4-LP Pulse output Wh or varh
Auxiliary supply 115 VAC or 230…240 VAC or 400 VAC
External interfaces Ethernet communication NT685, PROFIBUS communication NT592




Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Nemo D4-L – Network monitor for low voltage 4 module

    • Multifunction display for measurement acquisition in low-voltage networks
    • Suitable for single-phase networks and 3-/4-wire three-phase networks with unbalanced load
    • Three-phase network 50…450 V phase-phase, single-phase network 30…260 V
    • Current input 1 A or 5 A via external current transformers
    • Voltage input direct or via voltage transformer with adjustable transformer ratio
    • Measurement of active energy class 1 or reactive energy class 2
    • Depending on version without output, with RS485 communication or with pulse output
    • Backlit LCD display and 4-DIN-module design
    Datasheet
    User Manual

    Nemo D4-L / D4-LCM / D4-LP

    Multifunction display for low-voltage networks, 4 modules

    Type Multifunction display for electrical measurement acquisition in low-voltage networks
    Format 4 DIN modules
    Network Single-phase network and 3-/4-wire three-phase network, unbalanced load
    Three-phase network 50…450 V phase-phase
    Single-phase network 30…260 V
    Current input 1 A or 5 A, connection to external current transformers with adjustable CT ratio
    Voltage 50…450 V phase-phase, direct or via voltage transformer with adjustable VT ratio
    Measured values Active energy class 1 or reactive energy class 2
    Display Backlit LCD
    Output Nemo D4-L Without output
    Output Nemo D4-LCM RS485 communication
    Output Nemo D4-LP Pulse output Wh or varh
    Auxiliary supply 115 VAC or 230…240 VAC or 400 VAC
    External interfaces Ethernet communication NT685, PROFIBUS communication NT592




    Technical advice: 03303 / 50 40 66