RD1G – Residual current device 96x96mm


  • Delta 96-S residual current device in 96 × 96 mm format
  • For monitoring fault and leakage currents in low-voltage installations
  • 19 selectable measuring ranges from 0.03 A to 30 A
  • Instantaneous trip at IΔn 30 mA and adjustable intervention times up to 5 s
  • Instantaneous residual current display as percentage of IΔn via LED bar graph
  • Positive or negative relay safety selectable
  • Automatic permanent test as well as local, remote or automatic test and reset functions
  • Alarm relay with pre-alarm or double changeover contact depending on version
Datasheet

Delta 96-S

Residual current device, 96 × 96 mm

Type Residual current device for monitoring fault and leakage currents
Model Delta 96-S
Ordering code RD1G2…
Standard EN 60947-2 / IEC 60947-2
Ranges 19 ranges: 0.03…30 A; 18 ranges: 0.5…30 A
Instantaneous electrical trip Instantaneous trip t = 0 s at IΔn 30 mA
Waveform Sinusoidal, AC type; chopped pulsating with superimposed DC, A type
Filter for harmonics Selectable or fixed
Alarm 1 relay output, 2 relay outputs or 1 output + pre-alarm
IΔn display LED bar graph and display
Relay output SPDT, SPDT + SPST or 2 SPDT
Security Positive or negative safety selectable
Test Local, remote or automatic
Reset Local, remote or automatic
Auxiliary supply 230 VAC / AC; 24…48 / 115…240 / 400 VAC; 20…150 VDC; 10…36 VDC
Dimensions 96 × 96 mm
Input Low-voltage line with TDS series transformer
Rated frequency 50 / 60 Hz
Working frequency 47…63 Hz
Residual current setting Selectable by 2 rotary switches with 7 positions, 19 ranges
Non-operating residual current 0.5 × IΔn
Intervention time 0 / 0.15 / 0.25 / 0.5 / 1 / 2 / 5 s
Power-on signalling Green LED “ON”
Instantaneous value display LED bar graph 40…90 % of the set IΔn value
Alarm intervention Red LED “TRIP” and relay switching
Ring current transformer connection Via terminals
Alarm relay 2 SPDT contacts or 1 SPDT + 1 SPST contact, depending on version
Contact rating 5 A / 250 VAC at cosφ 1; 3 A / 250 VAC at cosφ 0.4; 5 A / 30 VDC
Installation category III
Pollution degree 2
Insulation reference voltage 450 V
Impulse withstand voltage 5 kV, 1.2/50 µs, 0.5 J
Operating temperature -5…50 °C
Storage temperature -25…70 °C
Protection degree IP30 front, IP20 terminals
Depth 88 mm
Weight 280 g








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    RD1G – Residual current device 96x96mm

    • Delta 96-S residual current device in 96 × 96 mm format
    • For monitoring fault and leakage currents in low-voltage installations
    • 19 selectable measuring ranges from 0.03 A to 30 A
    • Instantaneous trip at IΔn 30 mA and adjustable intervention times up to 5 s
    • Instantaneous residual current display as percentage of IΔn via LED bar graph
    • Positive or negative relay safety selectable
    • Automatic permanent test as well as local, remote or automatic test and reset functions
    • Alarm relay with pre-alarm or double changeover contact depending on version
    Datasheet

    Delta 96-S

    Residual current device, 96 × 96 mm

    Type Residual current device for monitoring fault and leakage currents
    Model Delta 96-S
    Ordering code RD1G2…
    Standard EN 60947-2 / IEC 60947-2
    Ranges 19 ranges: 0.03…30 A; 18 ranges: 0.5…30 A
    Instantaneous electrical trip Instantaneous trip t = 0 s at IΔn 30 mA
    Waveform Sinusoidal, AC type; chopped pulsating with superimposed DC, A type
    Filter for harmonics Selectable or fixed
    Alarm 1 relay output, 2 relay outputs or 1 output + pre-alarm
    IΔn display LED bar graph and display
    Relay output SPDT, SPDT + SPST or 2 SPDT
    Security Positive or negative safety selectable
    Test Local, remote or automatic
    Reset Local, remote or automatic
    Auxiliary supply 230 VAC / AC; 24…48 / 115…240 / 400 VAC; 20…150 VDC; 10…36 VDC
    Dimensions 96 × 96 mm
    Input Low-voltage line with TDS series transformer
    Rated frequency 50 / 60 Hz
    Working frequency 47…63 Hz
    Residual current setting Selectable by 2 rotary switches with 7 positions, 19 ranges
    Non-operating residual current 0.5 × IΔn
    Intervention time 0 / 0.15 / 0.25 / 0.5 / 1 / 2 / 5 s
    Power-on signalling Green LED “ON”
    Instantaneous value display LED bar graph 40…90 % of the set IΔn value
    Alarm intervention Red LED “TRIP” and relay switching
    Ring current transformer connection Via terminals
    Alarm relay 2 SPDT contacts or 1 SPDT + 1 SPST contact, depending on version
    Contact rating 5 A / 250 VAC at cosφ 1; 3 A / 250 VAC at cosφ 0.4; 5 A / 30 VDC
    Installation category III
    Pollution degree 2
    Insulation reference voltage 450 V
    Impulse withstand voltage 5 kV, 1.2/50 µs, 0.5 J
    Operating temperature -5…50 °C
    Storage temperature -25…70 °C
    Protection degree IP30 front, IP20 terminals
    Depth 88 mm
    Weight 280 g