ILMK307T ceramic sensor (flush) – level and temperature transmitter Ø 26,5


  • nominal pressure: from 0 … 4 mH2O up to 0 … 250 mH2O
  • nominal temperature from 0 … 30 °C up to 0 … 70 °C
  • accuracy: 0,5 % FSO
  • diameter 26,5 mm
  • separate output signals for pressure and temperture ranges
  • excellent accuracy
  • easy handling
  • low maintenance and wiring costs
Datasheet
User Manual

The stainless steel submersible probe ILMK 307T with flush mounted ceramic sensor developed for continuous level and temperature measurement in water or waste water applications.

The advantage: simultaneous recording of level and temperature with separate independent signal amplification. The maintenance and wiring costs are considerably reduced.

In addition to classical signal processing of the level, an additional signal circuit independent of the level which converts the temperature signal into a 4 … 20 mA analogue signal in 2-wire technology is provided.

 

Optional Features

  • different kinds of cables
  • different kinds of seal materials
  • customer specific versions
Pressure

38A: in bar ,  38B: in mH₂O 

Input

4001: 4 mH₂O / 0.4 bar, 6000: 6 mH₂O / 0.6 bar, 1001: 10 mH₂O / 1.0 bar, 1601: 16 mH₂O / 1.6 bar, 2501: 25 mH₂O / 2.5 bar, 4001: 40 mH₂O / 4.0 bar, 6001: 60 mH₂O / 6.0 bar, 1002: 100 mH₂O / 10 bar, 1602: 160 mH₂O / 16 bar, 2502: 250 mH₂O / 25 bar, 9999: Special ranges

Input Temperature

000×30: 0 … 30 °C, 000×50: 0 … 50 °C, 000×70: 0 … 70 °C, 999999: Special ranges

Housing

1: Stainless steel 1.4404 (316L), 9: others

Diaphragm

2: Ceramic Al₂O₃ 96%, 9: others

Output Pressure

1: 4 … 20 mA / 2-wire

Output Temperature

1: 4 … 20 mA / 2-wire

Seal

1: FKM, 3: EPDM, 9: others

Accuracy

5: 0.5 % FSO, 9: others

Electrical Connection / Cable Length

1003: PVC cable (grey, Ø 7.4 mm) 3 m, 1005: PVC cable (grey, Ø 7.4 mm) 5 m, 1010: PVC cable (grey, Ø 7.4 mm) 10 m, 1015: PVC cable (grey, Ø 7.4 mm) 15 m, 1999: PVC cable (grey, Ø 7.4 mm) special length in m, 2003: PUR cable (black, Ø 7.4 mm) 3 m, 2005: PUR cable (black, Ø 7.4 mm) 5 m, 2010: PUR cable (black, Ø 7.4 mm) 10 m, 2015: PUR cable (black, Ø 7.4 mm) 15 m, 2999: PUR cable (black, Ø 7.4 mm) special length in m, 3005: FEP cable (black, Ø 7.4 mm) 5 m, 3010: FEP cable (black, Ø 7.4 mm) 10 m, 3999: FEP cable (black, Ø 7.4 mm) special length in m

Special Versions

000: Standard, 999: others





Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    ILMK307T ceramic sensor (flush) – level and temperature transmitter Ø 26,5

    • nominal pressure: from 0 … 4 mH2O up to 0 … 250 mH2O
    • nominal temperature from 0 … 30 °C up to 0 … 70 °C
    • accuracy: 0,5 % FSO
    • diameter 26,5 mm
    • separate output signals for pressure and temperture ranges
    • excellent accuracy
    • easy handling
    • low maintenance and wiring costs
    Datasheet
    User Manual

    The stainless steel submersible probe ILMK 307T with flush mounted ceramic sensor developed for continuous level and temperature measurement in water or waste water applications.

    The advantage: simultaneous recording of level and temperature with separate independent signal amplification. The maintenance and wiring costs are considerably reduced.

    In addition to classical signal processing of the level, an additional signal circuit independent of the level which converts the temperature signal into a 4 … 20 mA analogue signal in 2-wire technology is provided.

     

    Optional Features

    • different kinds of cables
    • different kinds of seal materials
    • customer specific versions
    Pressure

    38A: in bar ,  38B: in mH₂O 

    Input

    4001: 4 mH₂O / 0.4 bar, 6000: 6 mH₂O / 0.6 bar, 1001: 10 mH₂O / 1.0 bar, 1601: 16 mH₂O / 1.6 bar, 2501: 25 mH₂O / 2.5 bar, 4001: 40 mH₂O / 4.0 bar, 6001: 60 mH₂O / 6.0 bar, 1002: 100 mH₂O / 10 bar, 1602: 160 mH₂O / 16 bar, 2502: 250 mH₂O / 25 bar, 9999: Special ranges

    Input Temperature

    000×30: 0 … 30 °C, 000×50: 0 … 50 °C, 000×70: 0 … 70 °C, 999999: Special ranges

    Housing

    1: Stainless steel 1.4404 (316L), 9: others

    Diaphragm

    2: Ceramic Al₂O₃ 96%, 9: others

    Output Pressure

    1: 4 … 20 mA / 2-wire

    Output Temperature

    1: 4 … 20 mA / 2-wire

    Seal

    1: FKM, 3: EPDM, 9: others

    Accuracy

    5: 0.5 % FSO, 9: others

    Electrical Connection / Cable Length

    1003: PVC cable (grey, Ø 7.4 mm) 3 m, 1005: PVC cable (grey, Ø 7.4 mm) 5 m, 1010: PVC cable (grey, Ø 7.4 mm) 10 m, 1015: PVC cable (grey, Ø 7.4 mm) 15 m, 1999: PVC cable (grey, Ø 7.4 mm) special length in m, 2003: PUR cable (black, Ø 7.4 mm) 3 m, 2005: PUR cable (black, Ø 7.4 mm) 5 m, 2010: PUR cable (black, Ø 7.4 mm) 10 m, 2015: PUR cable (black, Ø 7.4 mm) 15 m, 2999: PUR cable (black, Ø 7.4 mm) special length in m, 3005: FEP cable (black, Ø 7.4 mm) 5 m, 3010: FEP cable (black, Ø 7.4 mm) 10 m, 3999: FEP cable (black, Ø 7.4 mm) special length in m

    Special Versions

    000: Standard, 999: others





    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.