ILMK387 ceramic sensor (flush) – Stainless Steel Probe 22 mm


  • nominal pressure: from 0 … 1 mH2O up to 0 … 100 mH2O
  • accuracy: 0.35 % (opt. 0.25 %) FSO
  • diameter 22 mm
  • diaphragm ceramics Al2O3 (99.9 %)
  • excellent long term stability
  • highly appropriated for wastewater, sludge and viscous media

Datasheet
User Manual
User Manual

The stainless steel probe ILMK 387 was developed for level and gauge measurement in wastewater, sludge or water courses. The mechanical robustness of the front-flush ceramic diaphragm faciliates an easy disassembly and cleaning of the probe in case of service.

Compared to the level probe ILMK 382 the outside-diameter is only 22mm, which allows an easy installation and backfitting in 1″ tubes or in cramped fitting conditions. An IS-version is also available.

 

Optional Features

  • housing material titanium
  • IS-version
    Ex ia = intrinsically safe for gas and dust
  • drinking water certificate according to DVGW and KTW
  • temperature element Pt 100
  • mounting with stainless steel tube
  • different kinds of cables and elastomers
Pressure

360: relative in bar, 363: absolute in bar, 361: relative in mH₂O

Input

1000: 1.0 mH₂O / 0.10 bar, 1600: 1.6 mH₂O / 0.16 bar, 2500: 2.5 mH₂O / 0.25 bar, 4000: 4.0 mH₂O / 0.40 bar, 6000: 6.0 mH₂O / 0.60 bar, 1001: 10 mH₂O / 1.0 bar, 1601: 16 mH₂O / 1.6 bar, 2501: 25 mH₂O / 2.5 bar, 4001: 40 mH₂O / 4.0 bar, 6001: 60 mH₂O / 6.0 bar, 1002: 100 mH₂O / 10 bar, 9999: special measuring ranges

Housing

1: Stainless steel 1.4404 (316L), T: Titanium, 9: others

Build

1: Immersion probe, A: Screw-in probe with G1/2" open, B: Screw-in probe with G3/4" flush

Diaphragm

C: Ceramic Al₂O₃ 99.9%, 9: others

Output

1: 4 … 20 mA / 2-wire, E: Ex protection 4 … 20 mA / 2-wire, 9: others

Seal

1: FKM, 3: EPDM, 3T: EPDM (DVGW / KTW), 7: FFKM, 9: others

Electrical Connection

2: PUR cable (black, Ø 7.4 mm), 3: FEP cable (black, Ø 7.4 mm), 4: TPE-U cable (blue, Ø 7.4 mm), 42: TPE-U cable (red, Ø 9.0 mm), F: TPE-U cable (blue, Ø 7.4 mm) (DVGW / KTW), 9: others

Accuracy

3: Standard: 0.35 % FSO, 2: Option: 0.25 % FSO, 9: others

Cable Length

999: in m

Special Version

000: Standard, 013: with temperature sensor Pt 100, 502: prepared for installation with stainless steel tube, 999: others





Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    ILMK387 ceramic sensor (flush) – Stainless Steel Probe 22 mm

    • nominal pressure: from 0 … 1 mH2O up to 0 … 100 mH2O
    • accuracy: 0.35 % (opt. 0.25 %) FSO
    • diameter 22 mm
    • diaphragm ceramics Al2O3 (99.9 %)
    • excellent long term stability
    • highly appropriated for wastewater, sludge and viscous media

    Datasheet
    User Manual
    User Manual

    The stainless steel probe ILMK 387 was developed for level and gauge measurement in wastewater, sludge or water courses. The mechanical robustness of the front-flush ceramic diaphragm faciliates an easy disassembly and cleaning of the probe in case of service.

    Compared to the level probe ILMK 382 the outside-diameter is only 22mm, which allows an easy installation and backfitting in 1″ tubes or in cramped fitting conditions. An IS-version is also available.

     

    Optional Features

    • housing material titanium
    • IS-version
      Ex ia = intrinsically safe for gas and dust
    • drinking water certificate according to DVGW and KTW
    • temperature element Pt 100
    • mounting with stainless steel tube
    • different kinds of cables and elastomers
    Pressure

    360: relative in bar, 363: absolute in bar, 361: relative in mH₂O

    Input

    1000: 1.0 mH₂O / 0.10 bar, 1600: 1.6 mH₂O / 0.16 bar, 2500: 2.5 mH₂O / 0.25 bar, 4000: 4.0 mH₂O / 0.40 bar, 6000: 6.0 mH₂O / 0.60 bar, 1001: 10 mH₂O / 1.0 bar, 1601: 16 mH₂O / 1.6 bar, 2501: 25 mH₂O / 2.5 bar, 4001: 40 mH₂O / 4.0 bar, 6001: 60 mH₂O / 6.0 bar, 1002: 100 mH₂O / 10 bar, 9999: special measuring ranges

    Housing

    1: Stainless steel 1.4404 (316L), T: Titanium, 9: others

    Build

    1: Immersion probe, A: Screw-in probe with G1/2" open, B: Screw-in probe with G3/4" flush

    Diaphragm

    C: Ceramic Al₂O₃ 99.9%, 9: others

    Output

    1: 4 … 20 mA / 2-wire, E: Ex protection 4 … 20 mA / 2-wire, 9: others

    Seal

    1: FKM, 3: EPDM, 3T: EPDM (DVGW / KTW), 7: FFKM, 9: others

    Electrical Connection

    2: PUR cable (black, Ø 7.4 mm), 3: FEP cable (black, Ø 7.4 mm), 4: TPE-U cable (blue, Ø 7.4 mm), 42: TPE-U cable (red, Ø 9.0 mm), F: TPE-U cable (blue, Ø 7.4 mm) (DVGW / KTW), 9: others

    Accuracy

    3: Standard: 0.35 % FSO, 2: Option: 0.25 % FSO, 9: others

    Cable Length

    999: in m

    Special Version

    000: Standard, 013: with temperature sensor Pt 100, 502: prepared for installation with stainless steel tube, 999: others





    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.