ILMP307 stainless steel sensor – stainless steel probe Ø 27


  • nominal pressure: 0 … 1 mH2O up to 0 … 250 mH2O
  • accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
  • diameter 26.5 mm
  • small thermal effect
  • excellent long term stability
  • high accuracy

Datasheet
User Manual
User Manual

The stainless steel probe ILMP 307 is designed for continuous level measurement in water and clean or waste fluids.

The basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability.

 

Optional Features

  • IS-version
    Ex ia = intrinsically safe for gas and dust
  • SIL 2 (safety integrity level)
  • drinking water certificate acc. to DVGW and KTW
  • different kinds of cables and elastomers
  • petrol version, welded pressure sensor and housing
  • mounting with stainless steel pipe
Pressure

450: in bar, 451: in mH₂O

Input

1000: 1.0 mH₂O / 0.10 bar, 1600: 1.6 mH₂O / 0.16 bar, 2500: 2.5 mH₂O / 0.25 bar, 4000: 4.0 mH₂O / 0.40 bar, 6000: 6.0 mH₂O / 0.60 bar, 1010: 10 mH₂O / 1.0 bar, 1601: 16 mH₂O / 1.6 bar, 2501: 25 mH₂O / 2.5 bar, 4001: 40 mH₂O / 4.0 bar, 6001: 60 mH₂O / 6.0 bar, 1002: 100 mH₂O / 10 bar, 1602: 160 mH₂O / 16 bar, 2502: 250 mH₂O / 25 bar, 9999: Special measuring ranges

Housing

1: Edelstahl 1.4404 (316L), 9: andere

Diaphragm

1: Stainless steel 1.4404 (316L), 9: Other

Output

1: 4 … 20 mA / 2-wire, 2: 0 … 20 mA / 3-wire, 3: 0 … 10 V / 3-wire, E: 4 … 20 mA / 2-wire, Ex protection, 1S: 4 … 20 mA / 2-wire, SIL2, ES: SIL2 with Ex protection, 4: 4 … 20 mA / 2-wire, 9: Other

Seal

1: FKM, 3: EPDM, 3T: EPDM (DVGW/KTW), 21: Fuel version: without (welded version), 9: Other

Accuracy

3: Standard for pN ≥ 0.4 bar – 0.35% FSO, 5: Standard for pN < 0.4 bar – 0.5% FSO, 2: Option 1 for pN ≥ 0.4 bar – 0.25% FSO, 1: Option 2 – 0.1% FSO, 9: Other

Electrical Connection / Cable Length

1003: PVC-Kabel (grau, Ø 7,4 mm) 3 m, 1005: PVC-Kabel (grau, Ø 7,4 mm) 5 m, 1010: PVC-Kabel (grau, Ø 7,4 mm) 10 m, 1015: PVC-Kabel (grau, Ø 7,4 mm) 15 m, 1999: PVC-Kabel (grau, Ø 7,4 mm) Sonderlänge in m, 2003: PUR-Kabel (schwarz, Ø 7,4 mm) 3 m, 2005: PUR-Kabel (schwarz, Ø 7,4 mm) 5 m, 2010: PUR-Kabel (schwarz, Ø 7,4 mm) 10 m, 2015: PUR-Kabel (schwarz, Ø 7,4 mm) 15 m, 2999: PUR-Kabel (schwarz, Ø 7,4 mm) Sonderlänge in m, 3005: FEP-Kabel (schwarz, Ø 7,4 mm) 5 m, 3010: FEP-Kabel (schwarz, Ø 7,4 mm) 10 m, 3999: FEP-Kabel (schwarz, Ø 7,4 mm) Sonderlänge in m, 4999: TPE-U-Kabel (blau, Ø 7,4 mm) Sonderlänge in m, F999: DVGW/KTW Sonderlänge in m

Special Version

000: Standard, 503: vorbereitet für Montage mit Edelstahlrohr, 999: andere





Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    ILMP307 stainless steel sensor – stainless steel probe Ø 27

    • nominal pressure: 0 … 1 mH2O up to 0 … 250 mH2O
    • accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
    • diameter 26.5 mm
    • small thermal effect
    • excellent long term stability
    • high accuracy

    Datasheet
    User Manual
    User Manual

    The stainless steel probe ILMP 307 is designed for continuous level measurement in water and clean or waste fluids.

    The basic element is a high quality stainless steel sensor with high requirements for exact measurement with excellent long term stability.

     

    Optional Features

    • IS-version
      Ex ia = intrinsically safe for gas and dust
    • SIL 2 (safety integrity level)
    • drinking water certificate acc. to DVGW and KTW
    • different kinds of cables and elastomers
    • petrol version, welded pressure sensor and housing
    • mounting with stainless steel pipe
    Pressure

    450: in bar, 451: in mH₂O

    Input

    1000: 1.0 mH₂O / 0.10 bar, 1600: 1.6 mH₂O / 0.16 bar, 2500: 2.5 mH₂O / 0.25 bar, 4000: 4.0 mH₂O / 0.40 bar, 6000: 6.0 mH₂O / 0.60 bar, 1010: 10 mH₂O / 1.0 bar, 1601: 16 mH₂O / 1.6 bar, 2501: 25 mH₂O / 2.5 bar, 4001: 40 mH₂O / 4.0 bar, 6001: 60 mH₂O / 6.0 bar, 1002: 100 mH₂O / 10 bar, 1602: 160 mH₂O / 16 bar, 2502: 250 mH₂O / 25 bar, 9999: Special measuring ranges

    Housing

    1: Edelstahl 1.4404 (316L), 9: andere

    Diaphragm

    1: Stainless steel 1.4404 (316L), 9: Other

    Output

    1: 4 … 20 mA / 2-wire, 2: 0 … 20 mA / 3-wire, 3: 0 … 10 V / 3-wire, E: 4 … 20 mA / 2-wire, Ex protection, 1S: 4 … 20 mA / 2-wire, SIL2, ES: SIL2 with Ex protection, 4: 4 … 20 mA / 2-wire, 9: Other

    Seal

    1: FKM, 3: EPDM, 3T: EPDM (DVGW/KTW), 21: Fuel version: without (welded version), 9: Other

    Accuracy

    3: Standard for pN ≥ 0.4 bar – 0.35% FSO, 5: Standard for pN < 0.4 bar – 0.5% FSO, 2: Option 1 for pN ≥ 0.4 bar – 0.25% FSO, 1: Option 2 – 0.1% FSO, 9: Other

    Electrical Connection / Cable Length

    1003: PVC-Kabel (grau, Ø 7,4 mm) 3 m, 1005: PVC-Kabel (grau, Ø 7,4 mm) 5 m, 1010: PVC-Kabel (grau, Ø 7,4 mm) 10 m, 1015: PVC-Kabel (grau, Ø 7,4 mm) 15 m, 1999: PVC-Kabel (grau, Ø 7,4 mm) Sonderlänge in m, 2003: PUR-Kabel (schwarz, Ø 7,4 mm) 3 m, 2005: PUR-Kabel (schwarz, Ø 7,4 mm) 5 m, 2010: PUR-Kabel (schwarz, Ø 7,4 mm) 10 m, 2015: PUR-Kabel (schwarz, Ø 7,4 mm) 15 m, 2999: PUR-Kabel (schwarz, Ø 7,4 mm) Sonderlänge in m, 3005: FEP-Kabel (schwarz, Ø 7,4 mm) 5 m, 3010: FEP-Kabel (schwarz, Ø 7,4 mm) 10 m, 3999: FEP-Kabel (schwarz, Ø 7,4 mm) Sonderlänge in m, 4999: TPE-U-Kabel (blau, Ø 7,4 mm) Sonderlänge in m, F999: DVGW/KTW Sonderlänge in m

    Special Version

    000: Standard, 503: vorbereitet für Montage mit Edelstahlrohr, 999: andere





    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.