WIKA Pressure calibrator CPH6000, CPT6000 – Standard version


  • handheld pressure calibrator with easily interchangeable reference pressure sensors (sensor can also be attached externally)
  • Measuring ranges from 0 … 4 psi to 0 … 116,000 psi (0 … 250 mbar to 0 … 8,000 bar )
  • Accuracy: 0.025 % (incl. calibration certificate)
  • Calibration and pressure-switch test functions
  • Software and complete service cases (incl. pumps) available

Not available anymore. Successor Model CPH7000

Datasheet
User Manual

Applications for the Handheld Pressure Calibrator

  • Calibration service companies/service industry
  • Maintenance facilities
  • Measurement and control laboratories
  • Quality assurance

Handheld Pressure Calibrator Description

Applications
The CPH6000 Handheld Pressure Calibrator has the capability to connect to a variety of WIKA pressure sensors, with accuracies of up to 0.025% and measuring ranges up to116,000 psi. These sensors can be interchanged quickly and without tools. the CPH6000 Handheld Pressure Calibrator accomidated fixed sensors or can be used with externally connected sensors via an approx4 ft long connecting cable. When the sensor is changed, the digital indicator recognises the new range.

Functionality
The Handheld Pressure Calibrator menus provide 3 operating modes to choose from: MEASURING, CALIBRATION and PRESSURE SWITCHTEST. In the CALIBRATION and PRESSURE SWITCHTEST modes, a menu assistant supports the user during each operation and can record the calibration data from several calibrations or automatically calculates the switch hysteresis. To power the test item and to read its signals, there are electrical inputs and outputs which are protected from adverse conditions in the field by captive protection caps.

Software
For the evaluation and documentation of the calibration data stored in the CPH6000 Handheld Pressure Calibrator, WIKA-CAL calibration software is available. Using this software, the data is automatically transferred into a printable calibration certificate. WIKA-CAL also offers management of the calibration and instrument data in an SQL database. For data transfer, an RS-232 and a USB interface are available.

Complete test and service cases
For maintenance and service applications the CPH6000 Handheld Pressure Calibrator, offers various service cases. These include cases with or without pressure generation, charger, test-cable set, adapter, etc.

Certified accuracy
The Accuracy of each pressure sensor supplied with the Handheld Pressure Calibrator is certified by a factory calibration certificate which accompanies the instrument. On request, we can provide a calibration certificate traceable to national standards.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Pressure calibrator CPH6000, CPT6000 – Standard version

    • handheld pressure calibrator with easily interchangeable reference pressure sensors (sensor can also be attached externally)
    • Measuring ranges from 0 … 4 psi to 0 … 116,000 psi (0 … 250 mbar to 0 … 8,000 bar )
    • Accuracy: 0.025 % (incl. calibration certificate)
    • Calibration and pressure-switch test functions
    • Software and complete service cases (incl. pumps) available

    Not available anymore. Successor Model CPH7000

    Datasheet
    User Manual

    Applications for the Handheld Pressure Calibrator

    • Calibration service companies/service industry
    • Maintenance facilities
    • Measurement and control laboratories
    • Quality assurance

    Handheld Pressure Calibrator Description

    Applications
    The CPH6000 Handheld Pressure Calibrator has the capability to connect to a variety of WIKA pressure sensors, with accuracies of up to 0.025% and measuring ranges up to116,000 psi. These sensors can be interchanged quickly and without tools. the CPH6000 Handheld Pressure Calibrator accomidated fixed sensors or can be used with externally connected sensors via an approx4 ft long connecting cable. When the sensor is changed, the digital indicator recognises the new range.

    Functionality
    The Handheld Pressure Calibrator menus provide 3 operating modes to choose from: MEASURING, CALIBRATION and PRESSURE SWITCHTEST. In the CALIBRATION and PRESSURE SWITCHTEST modes, a menu assistant supports the user during each operation and can record the calibration data from several calibrations or automatically calculates the switch hysteresis. To power the test item and to read its signals, there are electrical inputs and outputs which are protected from adverse conditions in the field by captive protection caps.

    Software
    For the evaluation and documentation of the calibration data stored in the CPH6000 Handheld Pressure Calibrator, WIKA-CAL calibration software is available. Using this software, the data is automatically transferred into a printable calibration certificate. WIKA-CAL also offers management of the calibration and instrument data in an SQL database. For data transfer, an RS-232 and a USB interface are available.

    Complete test and service cases
    For maintenance and service applications the CPH6000 Handheld Pressure Calibrator, offers various service cases. These include cases with or without pressure generation, charger, test-cable set, adapter, etc.

    Certified accuracy
    The Accuracy of each pressure sensor supplied with the Handheld Pressure Calibrator is certified by a factory calibration certificate which accompanies the instrument. On request, we can provide a calibration certificate traceable to national standards.









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.