SMART 3NC point gas detector for non-classified areas and car parks


The SMART 3NC from Sensitron is a point gas detector for safe areas, with a number of features for easy operation and maintenance such as on going system self-diagnosis, seamless installation and maintenance via handheld keypad and options for relay output and Modbus communication.

Datasheet

Designed to be installed in non-classified areas and car parks, the Sensitron SMART 3NC is a IP55 rated point gas detector for safe areas. Developed to provide an affordable solution for underground garages and non-hazardous locations, without compromising on sophisticated detection.

Available for Methane, LPG, petrol vapours, CO, NO2 and CO2, these detectors use an industrial catalytic sensor for flammable gases, a three-electrode electrochemical cell for CO and NO2 and an infrared sensor for CO2.

Offering seamless installation, the SMART 3NC’s maintenance and calibration can be done via the handheld keypad STS/CKD, while its ongoing system self-diagnosis ensure correct detector operation and performance at all times.

The SMART 3NC also has Relay and Modbus communication options.

Specifications

Catalytic sensor Electrochemical cell Infrared sensor
Size Box: H100 x W100 x D52 mm (3.9 x 3.9 x 2ins)
Cover: H105.8 x W105.8 x D7.8 mm (4.2 x 4.2 x 0.3ins)
Weight 0.25kg
Enclosure material Polycarbonate
Ingress Protection IP55
Connection 2 x M20
Power 12-24 Vdc
Electrical output Analogue 4-20 mA output; 1 or 3 relay board (optional); serial RS485 output (optional)
Operating temperature -20 / +60°C -20 / +55°C -20 / +60°C
Humidity 0 / 90% RH 15 / 90% RH 0 / 90% RH
EMC compliance EN 61000-6-3:2007 + A1:2011; EN 50270:2015

 

Gases

Sensor type
Methane (CH4) Catalytic sensor
Petrol Vapours Catalytic sensor
LPG Catalytic sensor
Carbon Monoxide (CO) Electrochemical sensor
Nitrogen Dioxide (NO2) Electrochemical sensor
Chlorine (CL2) Electrochemical sensor
Sulphur Dioxide (SO2) Electrochemical sensor
Hydrogen Chloride (HCL) Electrochemical sensor
Carbon Dioxide (CO2) Infrared sensor








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    SMART 3NC point gas detector for non-classified areas and car parks

    The SMART 3NC from Sensitron is a point gas detector for safe areas, with a number of features for easy operation and maintenance such as on going system self-diagnosis, seamless installation and maintenance via handheld keypad and options for relay output and Modbus communication.

    Datasheet

    Designed to be installed in non-classified areas and car parks, the Sensitron SMART 3NC is a IP55 rated point gas detector for safe areas. Developed to provide an affordable solution for underground garages and non-hazardous locations, without compromising on sophisticated detection.

    Available for Methane, LPG, petrol vapours, CO, NO2 and CO2, these detectors use an industrial catalytic sensor for flammable gases, a three-electrode electrochemical cell for CO and NO2 and an infrared sensor for CO2.

    Offering seamless installation, the SMART 3NC’s maintenance and calibration can be done via the handheld keypad STS/CKD, while its ongoing system self-diagnosis ensure correct detector operation and performance at all times.

    The SMART 3NC also has Relay and Modbus communication options.

    Specifications

    Catalytic sensor Electrochemical cell Infrared sensor
    Size Box: H100 x W100 x D52 mm (3.9 x 3.9 x 2ins)
    Cover: H105.8 x W105.8 x D7.8 mm (4.2 x 4.2 x 0.3ins)
    Weight 0.25kg
    Enclosure material Polycarbonate
    Ingress Protection IP55
    Connection 2 x M20
    Power 12-24 Vdc
    Electrical output Analogue 4-20 mA output; 1 or 3 relay board (optional); serial RS485 output (optional)
    Operating temperature -20 / +60°C -20 / +55°C -20 / +60°C
    Humidity 0 / 90% RH 15 / 90% RH 0 / 90% RH
    EMC compliance EN 61000-6-3:2007 + A1:2011; EN 50270:2015

     

    Gases

    Sensor type
    Methane (CH4) Catalytic sensor
    Petrol Vapours Catalytic sensor
    LPG Catalytic sensor
    Carbon Monoxide (CO) Electrochemical sensor
    Nitrogen Dioxide (NO2) Electrochemical sensor
    Chlorine (CL2) Electrochemical sensor
    Sulphur Dioxide (SO2) Electrochemical sensor
    Hydrogen Chloride (HCL) Electrochemical sensor
    Carbon Dioxide (CO2) Infrared sensor








    Technical advice: 03303 / 50 40 66