TAQ6-M – Current transformers for low-voltage network, Measure


  • Current transformer for primary rated currents from 5 A to 40 A
  • Secondary current selectable with 5 A or 1 A
  • Suitable for 50 Hz, optionally also for 400 Hz with defined burden
  • Accuracy classes 0.5 and 1 available
  • Burden up to 6 VA at class 0.5 or up to 7.5 VA at class 1
  • Safety factor FS ≤ 5
  • Self-powered version without auxiliary supply
  • Optional ATAP015 accessory for protection with open secondary winding
Datasheet

Technical data

Primary rated current Ipn 5…40 A
Rated frequency 50 Hz
Operating frequency 47…63 Hz
Option Rated frequency 400 Hz, burden to be defined
Rated continuous thermal current Icth 100 % Ipr
Thermal continuous current Ith 30 Ipn
Dynamic rated current Idyn 2.5 Ith
Safety factor (FS) ≤ 5
Secondary current Isr 5 / 1 A
Burden 6 VA at class 0.5 / 7.5 VA at class 1
Accuracy Class 1 / class 0.5
Maximum power loss ≤ 4.3 W
Note on thermal dimensioning For thermal dimensioning of the control cabinet
Note on secondary winding With open secondary winding, an operating time of 1 minute is guaranteed.
Accessory ATAP015 (NT710) for automatic short-circuiting of the secondary winding when the limit value is exceeded
Auxiliary supply Not required, self-powered






Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    TAQ6-M – Current transformers for low-voltage network, Measure

    • Current transformer for primary rated currents from 5 A to 40 A
    • Secondary current selectable with 5 A or 1 A
    • Suitable for 50 Hz, optionally also for 400 Hz with defined burden
    • Accuracy classes 0.5 and 1 available
    • Burden up to 6 VA at class 0.5 or up to 7.5 VA at class 1
    • Safety factor FS ≤ 5
    • Self-powered version without auxiliary supply
    • Optional ATAP015 accessory for protection with open secondary winding
    Datasheet

    Technical data

    Primary rated current Ipn 5…40 A
    Rated frequency 50 Hz
    Operating frequency 47…63 Hz
    Option Rated frequency 400 Hz, burden to be defined
    Rated continuous thermal current Icth 100 % Ipr
    Thermal continuous current Ith 30 Ipn
    Dynamic rated current Idyn 2.5 Ith
    Safety factor (FS) ≤ 5
    Secondary current Isr 5 / 1 A
    Burden 6 VA at class 0.5 / 7.5 VA at class 1
    Accuracy Class 1 / class 0.5
    Maximum power loss ≤ 4.3 W
    Note on thermal dimensioning For thermal dimensioning of the control cabinet
    Note on secondary winding With open secondary winding, an operating time of 1 minute is guaranteed.
    Accessory ATAP015 (NT710) for automatic short-circuiting of the secondary winding when the limit value is exceeded
    Auxiliary supply Not required, self-powered






    Technical advice: 03303 / 50 40 66