SR360 – Alarm Unit with Current and Voltage Input and Double Relay Outputs


  • Monitoring relay for current and voltage signals in process applications
  • Current and voltage input with selectable input ranges
  • 2 output relays with independently configurable trip functions
  • Selectable high/low alarm and power failure alarm
  • Set point and hysteresis adjustable on the front
  • 3 LEDs for alarm status and supply voltage indication
  • 4 kV galvanic isolation between input, output and supply
  • Universal 24 V AC/DC supply and DIN rail mounting
Datasheet

SR360

Current and voltage monitoring relay for process applications

Type Monitoring relay for current and voltage signals in the process industry
Input Current and voltage input
Output 2 output relays with individually adjustable trip functions
Relay function Monostable relays for safe tripping in case of power failure
Relay contact SPDT relay with 6 A switching capacity
Configuration High configuration flexibility via DIP switches
Setting Trip point and hysteresis adjustable on the front
Display 3 front LEDs for trip and supply voltage monitoring
Insulation 4 kV insulation between input, output and supply voltage
Protection Protective separation according to EN 50178
Auxiliary supply Universal 24 V AC/DC supply voltage
Mounting DIN rail mounting
Current input 0/4 to 20 mA or ±20 mA, selectable by switch
Current input impedance 5 Ω
Current max. overload 200 mA
Voltage input 0 to 10 V or ±10 V, selectable by switch
Voltage input impedance 1 MΩ
Voltage max. overload 250 V
Relay contact output 1 & 2 Single-pole changeover contact, SPDT
Contact 250 VAC/DC, 6 A, 1500 VA
Relay function Monostable, normally active or passive, selectable by switch
Alarm function relay 1 High/low alarm, selectable by switch
Alarm function relay 2 High/low alarm or power failure alarm, selectable by switch
Alarm indication Alarm status indication via yellow LED
Adjustable alarm set point 0 to 100 % of input range, front potentiometer
Adjustable hysteresis 0 to 60 % of span, front potentiometer
Response time Approx. 20 ms, fixed
Operating temperature -20 to +60 °C / -4 to +140 °F
Galvanic isolation 4 kVAC, 1 min between input / supply voltage / relay outputs
Relay 1 / relay 2 2.5 kVAC, 1 min
Supply voltage 24 VAC/DC ±15 %, 48 to 62 Hz with AC supply
Power consumption AC approx. 2 VA, DC approx. 1 W
Typical accuracy Trip point ±0.2 % of span
Mounting Rail according to DIN EN 50022, 35 mm






Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    SR360 – Alarm Unit with Current and Voltage Input and Double Relay Outputs

    • Monitoring relay for current and voltage signals in process applications
    • Current and voltage input with selectable input ranges
    • 2 output relays with independently configurable trip functions
    • Selectable high/low alarm and power failure alarm
    • Set point and hysteresis adjustable on the front
    • 3 LEDs for alarm status and supply voltage indication
    • 4 kV galvanic isolation between input, output and supply
    • Universal 24 V AC/DC supply and DIN rail mounting
    Datasheet

    SR360

    Current and voltage monitoring relay for process applications

    Type Monitoring relay for current and voltage signals in the process industry
    Input Current and voltage input
    Output 2 output relays with individually adjustable trip functions
    Relay function Monostable relays for safe tripping in case of power failure
    Relay contact SPDT relay with 6 A switching capacity
    Configuration High configuration flexibility via DIP switches
    Setting Trip point and hysteresis adjustable on the front
    Display 3 front LEDs for trip and supply voltage monitoring
    Insulation 4 kV insulation between input, output and supply voltage
    Protection Protective separation according to EN 50178
    Auxiliary supply Universal 24 V AC/DC supply voltage
    Mounting DIN rail mounting
    Current input 0/4 to 20 mA or ±20 mA, selectable by switch
    Current input impedance 5 Ω
    Current max. overload 200 mA
    Voltage input 0 to 10 V or ±10 V, selectable by switch
    Voltage input impedance 1 MΩ
    Voltage max. overload 250 V
    Relay contact output 1 & 2 Single-pole changeover contact, SPDT
    Contact 250 VAC/DC, 6 A, 1500 VA
    Relay function Monostable, normally active or passive, selectable by switch
    Alarm function relay 1 High/low alarm, selectable by switch
    Alarm function relay 2 High/low alarm or power failure alarm, selectable by switch
    Alarm indication Alarm status indication via yellow LED
    Adjustable alarm set point 0 to 100 % of input range, front potentiometer
    Adjustable hysteresis 0 to 60 % of span, front potentiometer
    Response time Approx. 20 ms, fixed
    Operating temperature -20 to +60 °C / -4 to +140 °F
    Galvanic isolation 4 kVAC, 1 min between input / supply voltage / relay outputs
    Relay 1 / relay 2 2.5 kVAC, 1 min
    Supply voltage 24 VAC/DC ±15 %, 48 to 62 Hz with AC supply
    Power consumption AC approx. 2 VA, DC approx. 1 W
    Typical accuracy Trip point ±0.2 % of span
    Mounting Rail according to DIN EN 50022, 35 mm






    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.