Alternating voltage measuring relay RM2S (2 Module)


  • Three-phase monitoring relay for checking phase sequence, phase loss and voltage asymmetry
  • Suitable for three-phase networks 380…415 V with 50 or 60 Hz
  • Voltage asymmetry threshold adjustable from 5…25 %
  • Intervention delay adjustable from 0.2…10 s
  • Automatic reset after normal operating conditions are restored
  • Signalling via green power-on LED and red alarm LED
  • 1 SPDT relay output with positive safety
  • Self-supplied version without separate auxiliary supply
Datasheet

Three-Phase Monitoring Relay

Relay for monitoring voltage asymmetry, phase failure and phase sequence

Type Three-phase monitoring relay for checking voltage asymmetry, phase sequence and phase loss
Network Three-phase line 380…415 V, 50 and 60 Hz
Alarm functions Wrong phase sequence or phase connection, lack of one or more phases, voltage asymmetry
Rated voltage 380…415 V phase-phase
Waveform Sinusoidal, form factor 1.11
Rated frequency 50…60 Hz, selectable
Rated burden ≤ 2.7 VA
Voltage asymmetry threshold Continuously adjustable by trimmer, range 5…25 %
Intervention time Continuously adjustable by trimmer, range 0.2…10 s
Reset Automatic
Power-on signalling Green LED “ON”
Alarm signalling Red LED “Alarm” and relay switching
Output 1 SPDT relay contact
Contact rating 5 A / 250 VAC at cosφ 1; 3 A / 250 VAC at cosφ 0.4; 5 A / 30 VDC
Execution Positive safety, normally energized relay
Auxiliary supply Supply taken from measurement, self-supplied
Installation category III
Pollution degree 2
Insulation reference voltage 450 V
Impulse withstand voltage 5 kV, 1.2/50 µs, 0.5 J
Impulse test circuit Input, relay output
AC voltage test 1 2.5 kV R.M.S., 50 Hz / 1 min
AC test circuit 1 Input, relay output
AC voltage test 2 4 kV R.M.S., 50 Hz / 1 min
AC test circuit 2 All circuits and earth
EMC Emission tests according to EN 50081-1 / EN 55011, immunity tests according to EN 50082-2






Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Alternating voltage measuring relay RM2S (2 Module)

    • Three-phase monitoring relay for checking phase sequence, phase loss and voltage asymmetry
    • Suitable for three-phase networks 380…415 V with 50 or 60 Hz
    • Voltage asymmetry threshold adjustable from 5…25 %
    • Intervention delay adjustable from 0.2…10 s
    • Automatic reset after normal operating conditions are restored
    • Signalling via green power-on LED and red alarm LED
    • 1 SPDT relay output with positive safety
    • Self-supplied version without separate auxiliary supply
    Datasheet

    Three-Phase Monitoring Relay

    Relay for monitoring voltage asymmetry, phase failure and phase sequence

    Type Three-phase monitoring relay for checking voltage asymmetry, phase sequence and phase loss
    Network Three-phase line 380…415 V, 50 and 60 Hz
    Alarm functions Wrong phase sequence or phase connection, lack of one or more phases, voltage asymmetry
    Rated voltage 380…415 V phase-phase
    Waveform Sinusoidal, form factor 1.11
    Rated frequency 50…60 Hz, selectable
    Rated burden ≤ 2.7 VA
    Voltage asymmetry threshold Continuously adjustable by trimmer, range 5…25 %
    Intervention time Continuously adjustable by trimmer, range 0.2…10 s
    Reset Automatic
    Power-on signalling Green LED “ON”
    Alarm signalling Red LED “Alarm” and relay switching
    Output 1 SPDT relay contact
    Contact rating 5 A / 250 VAC at cosφ 1; 3 A / 250 VAC at cosφ 0.4; 5 A / 30 VDC
    Execution Positive safety, normally energized relay
    Auxiliary supply Supply taken from measurement, self-supplied
    Installation category III
    Pollution degree 2
    Insulation reference voltage 450 V
    Impulse withstand voltage 5 kV, 1.2/50 µs, 0.5 J
    Impulse test circuit Input, relay output
    AC voltage test 1 2.5 kV R.M.S., 50 Hz / 1 min
    AC test circuit 1 Input, relay output
    AC voltage test 2 4 kV R.M.S., 50 Hz / 1 min
    AC test circuit 2 All circuits and earth
    EMC Emission tests according to EN 50081-1 / EN 55011, immunity tests according to EN 50082-2