Limit Value Monitor DG 3101 – Economical Monitoring of Standard Signals with one Relay Output


The Limit Value Monitor DG 3101 is used to monitor measured values in 0(4) … 20 mA and 0 … 10 V standard signal circuits. A transmitter supply +Us is provided for the operation of 2-wire transmitters.

  • Easy configuration on front panel
    Operating mode switchable via DIP switch, switch point and hysteresis adjustable with potentiometer
  • Status indication by LED
    Easy monitoring and switching point adjustment
  • True 4-port separation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Protective Separation acc. to EN 61010
    Protects service personnel and downstream devices against impermissibly high voltage
  • High reliability and noise immunity
    No microprocessor, no integrated software
  • Extremely slim design
    12.5 mm slim housing for a simple and space saving DIN rail mounting
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant
Datasheet
User manual

The switching output can be configured with the analog control electronics as MIN or MAX alarm in open-circuit or closed-circuit operation.

All setting elements are located behind the openable front cover and can also be operated when the unit is mounted. The switching point and the switching hysteresis can be adjusted with potentiometers. The monitoring state is indicated by a yellow LED.

The relay changeover contact switches high power loads up to 6 A.

The Protective Separation and the 24 V DC power supply makes the DG 3101 universally applicable for all measurement and industrial applications, as well as for building automation.

Product line

Device Order No.
Limit Value Monitor with relay contact DG 3101

 

Technical Data

Input

Input signal 0(4) … 20 mA 0 … 10 V
Input resistance Current input approx. 5 Ω Voltage input approx. 120 kΩ
Overload max. Current input 200 mA Voltage input 300 V
Transmitter supply +Us 16 V at UPower = 24 V, (13 V … 22 V depending on the supply voltage)
current limited ≤ 30 mA
Switch point setting 0 to 110 % with 12-turn potentiometer
Hysteresis setting 0 to 6 % or 0 to 60 % of measuring range switchable, adjustable with potentiometer

Output

Contact type 1 changeover relay (SPDT)
Switching capability AC max. 250 V / 6 A,     1500 VA
Switching capability DC max. 250 V / 0.2 A,    115 V / 0.3 A    30 V / 6 A
Recommended minimum load 300 mW / 5 V / 5 mA
Status indication yellow LED
Response time approx. 20 ms

General Data

Switch error < 0.2 % full scale
Temperature coefficient 1) < 150 ppm/K
Test voltage 4 kV AC, 50 Hz, 1 min. input against power supply against switching output
Working voltage 2)
(Basic Insulation)
1000 V AC/DC for overvoltage category II and 600[nbp]V AC/DC for overvoltage category III acc. to EN 61010 and pollution degree 2 between input, power supply and switching output.
Protection against electrical shock 2) Protective separation according to DIN EN 61140 by reinforced insulation according to DIN EN 61010 up to 600 V AC/DC at overvoltage category II and 300 V AC/DC at overvoltage category III at pollution degree 2 between input, power supply and switching output.
Power supply 24 V DC, ± 15 %, approx. 0.8 W
Ambient temperature Operation
Transport and storage
–20 °C to +60 °C    (-4 to +140 °F)
–35 °C to +85 °C    (-31 to +185 °F)
EMC 3) EN 61326 -1
MTBF (acc. to EN 61709 / SN 29500) 575.4 years (Tamb. 40 °C, FIT 198)
Construction 12.5 mm (0.5″) housing, protection class IP 20, mounting on 35 mm DIN rail acc. to EN 60715
Connection Captive plus-minus clamp screws, Wire cross-section max. 2.5 mm² / AWG 14
Stripped length 6 … 8 mm / 0.28 in, Screw terminal torque 0.8 Nm / 7 lbf in
Weight 70 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  3. Minor deviations possible during interference

Block diagram

Dimensions

Terminal assignments

  • 1.1 +Power supply +
  • 1.2 −Power supply −
  • 2.2 ++Us
  • 2.1 +Voltage Input +
  • 3.1 +Current Input +
  • 3.2 −Input −
  • 4.1COM
  • 4.2NO
  • 5.1NC








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Limit Value Monitor DG 3101 – Economical Monitoring of Standard Signals with one Relay Output

    The Limit Value Monitor DG 3101 is used to monitor measured values in 0(4) … 20 mA and 0 … 10 V standard signal circuits. A transmitter supply +Us is provided for the operation of 2-wire transmitters.

    • Easy configuration on front panel
      Operating mode switchable via DIP switch, switch point and hysteresis adjustable with potentiometer
    • Status indication by LED
      Easy monitoring and switching point adjustment
    • True 4-port separation
      Protection against erroneous measurements due to parasitic voltages or ground loops
    • Protective Separation acc. to EN 61010
      Protects service personnel and downstream devices against impermissibly high voltage
    • High reliability and noise immunity
      No microprocessor, no integrated software
    • Extremely slim design
      12.5 mm slim housing for a simple and space saving DIN rail mounting
    • 5 Years Warranty
      Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant
    Datasheet
    User manual

    The switching output can be configured with the analog control electronics as MIN or MAX alarm in open-circuit or closed-circuit operation.

    All setting elements are located behind the openable front cover and can also be operated when the unit is mounted. The switching point and the switching hysteresis can be adjusted with potentiometers. The monitoring state is indicated by a yellow LED.

    The relay changeover contact switches high power loads up to 6 A.

    The Protective Separation and the 24 V DC power supply makes the DG 3101 universally applicable for all measurement and industrial applications, as well as for building automation.

    Product line

    Device Order No.
    Limit Value Monitor with relay contact DG 3101

     

    Technical Data

    Input

    Input signal 0(4) … 20 mA 0 … 10 V
    Input resistance Current input approx. 5 Ω Voltage input approx. 120 kΩ
    Overload max. Current input 200 mA Voltage input 300 V
    Transmitter supply +Us 16 V at UPower = 24 V, (13 V … 22 V depending on the supply voltage)
    current limited ≤ 30 mA
    Switch point setting 0 to 110 % with 12-turn potentiometer
    Hysteresis setting 0 to 6 % or 0 to 60 % of measuring range switchable, adjustable with potentiometer

    Output

    Contact type 1 changeover relay (SPDT)
    Switching capability AC max. 250 V / 6 A,     1500 VA
    Switching capability DC max. 250 V / 0.2 A,    115 V / 0.3 A    30 V / 6 A
    Recommended minimum load 300 mW / 5 V / 5 mA
    Status indication yellow LED
    Response time approx. 20 ms

    General Data

    Switch error < 0.2 % full scale
    Temperature coefficient 1) < 150 ppm/K
    Test voltage 4 kV AC, 50 Hz, 1 min. input against power supply against switching output
    Working voltage 2)
    (Basic Insulation)
    1000 V AC/DC for overvoltage category II and 600[nbp]V AC/DC for overvoltage category III acc. to EN 61010 and pollution degree 2 between input, power supply and switching output.
    Protection against electrical shock 2) Protective separation according to DIN EN 61140 by reinforced insulation according to DIN EN 61010 up to 600 V AC/DC at overvoltage category II and 300 V AC/DC at overvoltage category III at pollution degree 2 between input, power supply and switching output.
    Power supply 24 V DC, ± 15 %, approx. 0.8 W
    Ambient temperature Operation
    Transport and storage
    –20 °C to +60 °C    (-4 to +140 °F)
    –35 °C to +85 °C    (-31 to +185 °F)
    EMC 3) EN 61326 -1
    MTBF (acc. to EN 61709 / SN 29500) 575.4 years (Tamb. 40 °C, FIT 198)
    Construction 12.5 mm (0.5″) housing, protection class IP 20, mounting on 35 mm DIN rail acc. to EN 60715
    Connection Captive plus-minus clamp screws, Wire cross-section max. 2.5 mm² / AWG 14
    Stripped length 6 … 8 mm / 0.28 in, Screw terminal torque 0.8 Nm / 7 lbf in
    Weight 70 g
    1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
    2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
    3. Minor deviations possible during interference

    Block diagram

    Dimensions

    Terminal assignments

    • 1.1 +Power supply +
    • 1.2 −Power supply −
    • 2.2 ++Us
    • 2.1 +Voltage Input +
    • 3.1 +Current Input +
    • 3.2 −Input −
    • 4.1COM
    • 4.2NO
    • 5.1NC