2-Channel Isolation Amplifier DN 26000 – Isolation and Conversion of Standard Signals


The 2-Channel Isolation Amplifier DN 26000 is used for isolation and conversion of 0/4 … 20 mA and 0 … 10 V, 0 … 5 V standard signals.

  • Calibrated signal setting via DIP switch
    Input and output range can be set by using DIP switch – high precision without any further adjustment
  • 5-Port Isolation
    Protection against erroneous measurements due to parasitic voltages or ground loops
  • Extremely slim design
    6.2 mm slim housing for a simple and space saving DIN rail mounting
  • Power supply via In-Rail-connector
    allows fast and economical installation
  • Protective Separation acc. to EN 61140
    Protects service personnel and downstream devices against impermissibly high voltage
  • Maximum reliability
    No maintenance costs
  • 5 Years Warranty
    Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
Datasheet
User Manual

Due to the extremely slim design, the space requirement is only 3 mm per channel. The input and output ranges can be selected individually for each channel via DIP switches. A readjustment is not necessary due to the calibrated measuring ranges. A signal clipping and the cut-off frequency can also be set via DIP switches.

The power is supplied via the In- Rail-Bus, which ensures prewiring on a standard DIN rail. This significantly reduces the wiring effort. A green LED on the front of the unit has been provided to monitor the power supply.

Product line

Device Type Order No.
2-Channel Isolation Amplifier DN 26000 B

In-Rail-Bus for power supply (see accessories)

 

Technical Data

Inputs

Input signal
(calibrated switchable)
0 … 20 mA, 4 … 20 mA
0 … 10 V, 0 … 5 V
Input resistance Current input
Voltage input
≤ 25 Ohm
≥ 100 kOhm
Overload Current input
Voltage input
< 50 mA
< 30 V

Outputs

Output signal
(calibrated switchable)
0 … 20 mA, 4 … 20 mA
0 … 10 V, 0 … 5 V
Load Current output:
Voltage output:
≤ 10 V (500 Ohm at 20 mA)
≤ 5 mA (2 kOhm at 10 V)
Linear transmission range -1 … +110 %
Residual ripple < 10 mVeff

General Data

Transmission error < 0.1 % full scale
Temperature coefficient 1) < 100 ppm/K
Cut-off frequency -3 dB 100 Hz       10 Hz       (switchable)
Response time T99 10 ms       55 ms
Test voltage 3 kV AC, 50 Hz, 1 min.,
Inputs against outputs against power supply
Working voltage 2)
(Basic insulation)
600 V AC/DC for overvoltage category II and pollution
degree 2 acc. to EN 61010-1
Protection against
electrical shock
Protective separation according to EN 61140 by reinforced
insulation in accordance with EN 61010-1 up to 300 V AC/DC
for overvoltage category II and pollution degree 2 between
all circuits
Ambient temperature Operation
Transport and storage
–25 °C to +70 °C   (-13 to +158 °F)
–40 °C to +85 °C   (-40 to +185 °F)
Power supply 24 V DC via In-Rail-Bus    voltage range 16.8 V … 31.2 V DC, approx. 1.1 W
EMC 3) EN 61326-1
Construction 6.2 mm (0.244″) housing, protection class IP 20,
mounting on 35 mm DIN rail acc. to EN 60715
Connection Captive plus-minus clamp screws
Wire cross-section 0.5 … 2.5 mm2
Stripped length 8 mm
Screw terminal torque 0.6 Nm
Weight Approx. 70 g
  1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
  2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  3. Minor deviations possible during interference

Block diagram

Dimensions

Terminal assignments

  • Channel 1
  • 1Input (+U/-I)
  • 2Input (-U/+I)
  • 5 +Output
  • 6 −Output
  • Channel 2
  • 3Input (+U/-I)
  • 4Input (+U/-I)
  • 7 +Output
  • 8 −Output
  • D +Power supply In-Rail-Bus D
  • C −Power supply In-Rail-Bus C

Power connection via In-Rail-Bus (see accessories)









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    2-Channel Isolation Amplifier DN 26000 – Isolation and Conversion of Standard Signals

    The 2-Channel Isolation Amplifier DN 26000 is used for isolation and conversion of 0/4 … 20 mA and 0 … 10 V, 0 … 5 V standard signals.

    • Calibrated signal setting via DIP switch
      Input and output range can be set by using DIP switch – high precision without any further adjustment
    • 5-Port Isolation
      Protection against erroneous measurements due to parasitic voltages or ground loops
    • Extremely slim design
      6.2 mm slim housing for a simple and space saving DIN rail mounting
    • Power supply via In-Rail-connector
      allows fast and economical installation
    • Protective Separation acc. to EN 61140
      Protects service personnel and downstream devices against impermissibly high voltage
    • Maximum reliability
      No maintenance costs
    • 5 Years Warranty
      Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
    Datasheet
    User Manual

    Due to the extremely slim design, the space requirement is only 3 mm per channel. The input and output ranges can be selected individually for each channel via DIP switches. A readjustment is not necessary due to the calibrated measuring ranges. A signal clipping and the cut-off frequency can also be set via DIP switches.

    The power is supplied via the In- Rail-Bus, which ensures prewiring on a standard DIN rail. This significantly reduces the wiring effort. A green LED on the front of the unit has been provided to monitor the power supply.

    Product line

    Device Type Order No.
    2-Channel Isolation Amplifier DN 26000 B

    In-Rail-Bus for power supply (see accessories)

     

    Technical Data

    Inputs

    Input signal
    (calibrated switchable)
    0 … 20 mA, 4 … 20 mA
    0 … 10 V, 0 … 5 V
    Input resistance Current input
    Voltage input
    ≤ 25 Ohm
    ≥ 100 kOhm
    Overload Current input
    Voltage input
    < 50 mA
    < 30 V

    Outputs

    Output signal
    (calibrated switchable)
    0 … 20 mA, 4 … 20 mA
    0 … 10 V, 0 … 5 V
    Load Current output:
    Voltage output:
    ≤ 10 V (500 Ohm at 20 mA)
    ≤ 5 mA (2 kOhm at 10 V)
    Linear transmission range -1 … +110 %
    Residual ripple < 10 mVeff

    General Data

    Transmission error < 0.1 % full scale
    Temperature coefficient 1) < 100 ppm/K
    Cut-off frequency -3 dB 100 Hz       10 Hz       (switchable)
    Response time T99 10 ms       55 ms
    Test voltage 3 kV AC, 50 Hz, 1 min.,
    Inputs against outputs against power supply
    Working voltage 2)
    (Basic insulation)
    600 V AC/DC for overvoltage category II and pollution
    degree 2 acc. to EN 61010-1
    Protection against
    electrical shock
    Protective separation according to EN 61140 by reinforced
    insulation in accordance with EN 61010-1 up to 300 V AC/DC
    for overvoltage category II and pollution degree 2 between
    all circuits
    Ambient temperature Operation
    Transport and storage
    –25 °C to +70 °C   (-13 to +158 °F)
    –40 °C to +85 °C   (-40 to +185 °F)
    Power supply 24 V DC via In-Rail-Bus    voltage range 16.8 V … 31.2 V DC, approx. 1.1 W
    EMC 3) EN 61326-1
    Construction 6.2 mm (0.244″) housing, protection class IP 20,
    mounting on 35 mm DIN rail acc. to EN 60715
    Connection Captive plus-minus clamp screws
    Wire cross-section 0.5 … 2.5 mm2
    Stripped length 8 mm
    Screw terminal torque 0.6 Nm
    Weight Approx. 70 g
    1. Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
    2. For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
    3. Minor deviations possible during interference

    Block diagram

    Dimensions

    Terminal assignments

    • Channel 1
    • 1Input (+U/-I)
    • 2Input (-U/+I)
    • 5 +Output
    • 6 −Output
    • Channel 2
    • 3Input (+U/-I)
    • 4Input (+U/-I)
    • 7 +Output
    • 8 −Output
    • D +Power supply In-Rail-Bus D
    • C −Power supply In-Rail-Bus C

    Power connection via In-Rail-Bus (see accessories)









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.