When it comes to individualized solutions, the know-how advantage of our development team stands ready to serve. This allows us to offer customer-specific solutions with the proverbial DRAGO quality in the shortest possible time; solutions which, as a result of individualized consultation, optimally meet all customer needs, including their economic ones.
The slim housing with 12.5 mm width saves space in the switch cabinet and facilitates by the practical plug-in screw terminal blocks the assembly.
The new universal power pack for 20 to 253 V AC/DC means the DK 8000 can be used anywhere in the world, with all mains power supplies. The unit’s high efficiency contributes significantly to reducing the unit’s own heat generation. This is reflected in extremely high reliability and long-term stability.
Product line
Devices | Order No. |
---|---|
Customer-Specific Isolation Amplifier | DK 8000 – XXX |
The index number – XXX describes the signal combination and will be announced by order. |
Technical Data
Input
Input signals | Customer-specific technical data as orders (see label) |
|
Input resistance | Current input Voltage input |
approx. 25 Ohm (depends on measuring range) approx. 1 MOhm (depends on measuring range) |
Overload | Max. 120 % of final value |
Output
Output signals | Customer-specific technical data as orders (see label) |
|
Load | Current output Voltage output |
≤ 12 V (600 Ohm at 20 mA) ≤ 20 mA (500 Ohm at 10 V) |
Transmission range | unipolar: –2 … +110 %, bipolar: –110 … +110 % | |
Residual ripple | < 10 mVrms |
General Data
Transmission error | Typical 0.1 % full scale (max. 0.3 %, depends on measuring range) | |
Temperature coefficient 1) | < 100 ppm/K | |
Zero/Span Adjustment | Optional | |
Cut-off frequency -3 dB | Max. 10 kHz | |
Test voltage | 4 kV AC, 50 Hz, 1 min., input against output against power supply | |
Working voltage 2) (Basic Insulation) |
1000 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010–1 | |
Ambient temperature | Operation Transport and storage |
–20 °C to +70 °C (-4 to +158 °F) –35 °C to +85 °C (-31 to +185 °F) |
Power supply | 20 to 253 V AC/DC | AC 48 to 62 Hz, approx. 2 VA DC approx. 1.0 W |
EMC 3) | EN 61326-1 | |
Construction | 12.5 mm (0.49″) housing, protection class: IP 20 mounting on 35 mm DIN rail acc. to EN 60715 |
|
Weight | Approx. 100 g |
- Average TC related to full scale value in specified operating temperature range, reference temperature 23 °C
- For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
- Minor deviations possible during interference
Block diagram

Dimensions
Terminal assignments
- 1 +Input
- 2 −Input
- 3 +Input
- 4 −Input
- 5 +Output
- 6 −Output
- 7Power supply AC/DC
- 8Power supply AC/DC
Pluggable screw clamp terminals
Wire cross-section max. 2.5 mm², Multi-wire connection max. 1 mm² (two wires with same cross-section)