The IP131 pressure transmitter features large process connections and a front-flush measuring sensor. Clogging of the membrane is prevented most effectively and can be easily cleaned if necessary. ATEX and DNV-GL certified, the sensor can also be used in potentially explosive areas and features excellent mechanical strength. The ceramic sensor element is resistant to aggressive and abrasive media. The capacitive measuring principle enables a very accurate and long term stable measurement, even at lowest pressures and high overload resistance. The process connection is made of high-quality materials such as stainless steel 1.4404 or PVDF and is therefore suitable for almost all media. Our modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this data sheet.
Applications:
- Viscous and pasty media
- Hygiene applications
- Gaseous media
- Liquid media
- Abrasive media
- Aggressive media
- Potentially explosive areas
Technical data:
Measuring ranges | Smallest measuring range: 0…30 mbar |
Largest measuring range: 0…40 bar | |
Negative pressure measuring range: up to -1 bar | |
Analog output | 4…20 mA, 2-wires |
4…20 mA, 2-wires, II 1G Ex ia IIC T4 Ga | |
0…10 V, 3-wires | |
Power supply | 20 mA output: 9…30 V DC |
10 V output: 15…30 V DC | |
Accuracy | ≤ ± 0,2 % FS @ 25 °C |
≤ ± 0,5 % FS @ 25°C ≤ 60 mbar | |
Long term stability | ≤ ± 0,15 % FS / Year |
Response time | 200 ms – others on request |
Swich-on time | < 1 s |
Temperature coefficient | Zero: ≤ ± 0,015 % FS / Kelvin |
Span: ≤ ± 0,01 % FS / Kelvin | |
Medium temperature | -40…100 °C (125 °C < 0,5 h) |
-20…80 °C with EX ia IIC T4 | |
Surrounding temperature | -25…80 °C |
-20…80 °C with EX ia IIC T4 | |
Storage temperature | -40…85 °C |
Short-circuit resistance | Permanent |
Reverse polarity protection | Protection against reverse polarity, but no function |
Electromagnetic compatibility | Interference emissions and immunity acc. to EN 61326 |
Vibration | 4g with 3-axis resonance frequency according to DIN EN 60068-2-6:2008 |
Wetted materials | Process connection: Stainless steel 1.4404 |
Sensor: Ceramic Al2O3 – FDA | |
Process seal: FPM (Viton), NBR, EPDM, FFKM (Chemraz / Kalrez) | |
Protection type | IP 65 |
IP 67 with cable connection | |
Weight | Approx. 250 g |