Showing all 22 results

  • For the connection of Pt100 and Pt1000 sensors in a 2-, 3- or 4-wire connection
  • For the connection of reed chains in a potentiometer circuit
  • Parameterisation with the WIKAsoft-TT configuration software and electrical connection via quick connector magWIK
  • Connection terminals also accessible from the outside
  • Accuracy < 0.2 K (< 0,36 °F) / 0.1 %
Datasheet
User Manual

  • TÜV zertifizierte SIL-Version für Schutzeinrichtungen entwickelt nach IEC 61508 (Option)
  • Einsatz in Sicherheitsanwendungen bis SIL 2 (einzelnes Gerät) und SIL 3 (redundante Verschaltung)
  • Konfigurierbar mit nahezu jedem offenen Soft- und Hardwaretool
  • Universell für den Anschluss von 1 oder 2 Sensoren - Widerstandsthermometer, Widerstandssensor - Thermoelement, mV-Sensor - Potentiometer
  • Signalisierung gemäß NAMUR NE43, Sensorbruchüberwachung gemäß NE89, EMV gemäß NE21
Datenblatt
Bedienungsanleitung

  • TÜV certified SIL version for protection systems developed per IEC 61508 (option)
  • Operation in safety applications to SIL 2 (single instrument) and SIL 3 (redundant configuration)
  • Configurable with almost all soft- and hardware tools
  • Universal for the connection of 1 or 2 sensors
    • Resistance thermometer, resistance sensor (up to 2 x 3-wire)
    • Thermocouple, mV sensor
    • Potentiometer
  • Signalling in accordance with NAMUR NE43, sensor monitoring in accordance with NE89, EMC in accordance with NE21, self-monitoring and diagnostics of field instruments in accordance with NE107
Datenblatt
Datenblatt

  • Model OTMT84: PROFIBUS® PA profile 3.02
  • Model OTMT85: FOUNDATION™ Fieldbus H1
  • Explosion-protected version Ex ia (intrinsically safe/FISCO) and Ex ec available
Datasheet
User Manual
User Manual

Digital 2-wire transmitter for Pt100 and Pt1000 with wireless communication

  • Type: Digital
  • Input: RTD
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Digital 2-wire transmitter for thermocouple with wireless communication

  • Type: Digital
  • Input: TC
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Analog Adjustable 3-wire Transmitters
  • Type: Analog
  • Input: RTD
  • Utgång: 0-10 V
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Analog Adjustable 3-wire Transmitters
  • Type: Analog
  • Input: RTD
  • Utgång: 0-10 V
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Analog Adjustable 2-wire Transmitters
  • Type: Analog
  • Input: RTD, thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel


Datasheet

Analog Adjustable 2-wire Transmitters
  • Type: Analog
  • Input: RTD, thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel


Datasheet

TypeHead-mounted
InputRTD
Input RTDPt100
Type Of TransmitterAnalog
Output4-20 mA
IsolationUnisolated
Measuring channels1 channel
Input connections3-wire connection
Power supply8.5 to 32 VDC
Typical accuracyMax. of ±0.1 °C / ±0.2 °F or ±0,1 % of span
Quick deliveryYes
Datasheet

TypeHead mounted
InputRTD
Input RTDPt100
Type of transmitterDigital
Output4-20 mA
IsolationUnisolated
Measuring channels1 channel
Sensor connection3-wire connection
Power SupplyStandard version: 6 to 32 VDC Ex version: 8 to 30 VDC
Typical accuracyMax. ±0.1K or ±0,1 % of span
Approvals (IPAQ-C202X)ATEX: II 1G Ex ia IIC T6…T4 Ga IECEx: Ex ia IIC T6…T4 Ga
Datasheet

TypeHead mounted
InputRTD
Input RTDPt100
Type of transmitterDigital
Output4-20 mA
IsolationUnisolated
Measuring channels1 channel
Sensor connection3-wire connection
Power SupplyStandard version: 6 to 32 VDC Ex version: 8 to 30 VDC
Typical accuracyMax. ±0.1K or ±0,1 % of span
Approvals (IPAQ-C202X)ATEX: II 1G Ex ia IIC T6…T4 Ga IECEx: Ex ia IIC T6…T4 Ga
Datasheet

Universal 2-wire transmitter with wireless communication
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

Universal 2-wire transmitter with wireless communication
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel


Datasheet

High-precision Universal Programmable 2-wire Transmitter
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

High-precision Universal Programmable 2-wire Transmitter
  • Type: Digital
  • Input: RTD, thermocouple, Universal
  • Output: 4-20 mA
  • Isolation: Isolated
  • Measuring channels: 1 channel
Datasheet

 
TypKopftransmitter
EingangRTD; Thermoelement; Universal
Eingang WiderstandsthermometerPt100, Pt1000, Ni100, Ni1000
Eingang ThermoelementeTyp B, C, E, J, K, L, N, R, S, T, U
TransmittertypDigital
Ausgang4-20 mA; HART®
Galvanische TrennungJa
Messkanäle1 Kanal
Eingang3-, 4-Leiteranschluss
VersorgungsspannungMESO-H: 10 bis 42 VDC; MESO-HX: 12 bis 30 VDC
ZulassungATEX; CSA; FM; HART®
Typische Genauigkeit0.1% der Messspanne
INOR SchnelllieferprogrammJa
Datasheet

Basic Programmable 2-wire Transmitter

  • Type: Digital
  • Input: RTD thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

Basic Programmable 2-wire Transmitter

  • Type: Digital
  • Input: RTD thermocouple
  • Output: 4-20 mA
  • Isolation: Unisolated
  • Measuring channels: 1 channel
Datasheet

2-wire head transmitter with and without HART communications interface for mounting in the connection head of the temperature sensor.

Datasheet
User Manual

2-wire head transmitter with and without HART communications interface for mounting in the connection head of the temperature sensor.

Datasheet
User Manual

Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.
This site is registered on wpml.org as a development site.