Pressure Transmitter IP131


  • Front flush dry ceramic sensor
  • Smallest measuring range: 0…30 mbar
  • Largest measuring range: 0…40 bar
  • Negative pressure measuring range: up to -1 bar
  • Accuracy ≤ 0,2%
  • High overload capability
  • Rugged design
  • Optionally in plastic PVDF
  • Analog output: 4…20 mA, 2-wires
    0…10 V, 3-wires
  • DNV-GL certified
  • Ex II 1G Ex ia IIC T4 Ga
    I M2 Ex ia I Mb

Datasheet
User Manual
User Manual

The  IP131  pressure  transmitter  features large process connections and a front-flush measuring sensor.  Clogging  of  the  membrane is prevented most effectively and can be easily cleaned if necessary. ATEX and DNV-GL certified, the sensor can also be used in potentially explosive areas and features excellent mechanical strength.  The  ceramic  sensor  element  is  resistant  to  aggressive  and  abrasive media.  The  capacitive measuring principle  enables  a  very  accurate  and  long  term  stable  measurement,  even  at  lowest  pressures  and  high  overload  resistance.  The  process connection is made of high-quality materials such as stainless steel  1.4404 or  PVDF and is therefore suitable for almost all media.  Our  modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this data sheet.

 

Applications:

  • Viscous and pasty media
  • Hygiene applications
  • Gaseous media
  • Liquid media
  • Abrasive media
  • Aggressive media
  • Potentially explosive areas

 

Technical data:

Measuring ranges Smallest measuring range: 0…30 mbar
Largest measuring range: 0…40 bar
Negative pressure measuring range: up to -1 bar
Analog output 4…20 mA, 2-wires
4…20 mA, 2-wires, II 1G Ex ia IIC T4 Ga
0…10 V, 3-wires
Power supply 20 mA output: 9…30 V DC
10 V output: 15…30 V DC
Accuracy ≤ ± 0,2 % FS @ 25 °C
≤ ± 0,5 % FS @ 25°C ≤ 60 mbar
Long term stability ≤ ± 0,15 % FS / Year
Response time 200 ms – others on request
Swich-on time < 1 s
Temperature coefficient Zero: ≤ ± 0,015 % FS / Kelvin
Span: ≤ ± 0,01 % FS / Kelvin
Medium temperature -40…100 °C (125 °C < 0,5 h)
-20…80 °C with EX ia IIC T4
Surrounding temperature -25…80 °C
-20…80 °C with EX ia IIC T4
Storage temperature -40…85 °C
Short-circuit resistance Permanent
Reverse polarity protection Protection against reverse polarity, but no function
Electromagnetic compatibility Interference emissions and immunity acc. to EN 61326
Vibration 4g with 3-axis resonance frequency according to DIN EN 60068-2-6:2008
Wetted materials Process connection: Stainless steel 1.4404
Sensor: Ceramic Al2O– FDA
Process seal: FPM (Viton), NBR, EPDM, FFKM (Chemraz / Kalrez)
Protection type IP 65
IP 67 with cable connection
Weight Approx. 250 g








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Pressure Transmitter IP131

    • Front flush dry ceramic sensor
    • Smallest measuring range: 0…30 mbar
    • Largest measuring range: 0…40 bar
    • Negative pressure measuring range: up to -1 bar
    • Accuracy ≤ 0,2%
    • High overload capability
    • Rugged design
    • Optionally in plastic PVDF
    • Analog output: 4…20 mA, 2-wires
      0…10 V, 3-wires
    • DNV-GL certified
    • Ex II 1G Ex ia IIC T4 Ga
      I M2 Ex ia I Mb

    Datasheet
    User Manual
    User Manual

    The  IP131  pressure  transmitter  features large process connections and a front-flush measuring sensor.  Clogging  of  the  membrane is prevented most effectively and can be easily cleaned if necessary. ATEX and DNV-GL certified, the sensor can also be used in potentially explosive areas and features excellent mechanical strength.  The  ceramic  sensor  element  is  resistant  to  aggressive  and  abrasive media.  The  capacitive measuring principle  enables  a  very  accurate  and  long  term  stable  measurement,  even  at  lowest  pressures  and  high  overload  resistance.  The  process connection is made of high-quality materials such as stainless steel  1.4404 or  PVDF and is therefore suitable for almost all media.  Our  modular design concept provides a wide variety of products. Feel free to contact us if you need a customization that is not listed in this data sheet.

     

    Applications:

    • Viscous and pasty media
    • Hygiene applications
    • Gaseous media
    • Liquid media
    • Abrasive media
    • Aggressive media
    • Potentially explosive areas

     

    Technical data:

    Measuring ranges Smallest measuring range: 0…30 mbar
    Largest measuring range: 0…40 bar
    Negative pressure measuring range: up to -1 bar
    Analog output 4…20 mA, 2-wires
    4…20 mA, 2-wires, II 1G Ex ia IIC T4 Ga
    0…10 V, 3-wires
    Power supply 20 mA output: 9…30 V DC
    10 V output: 15…30 V DC
    Accuracy ≤ ± 0,2 % FS @ 25 °C
    ≤ ± 0,5 % FS @ 25°C ≤ 60 mbar
    Long term stability ≤ ± 0,15 % FS / Year
    Response time 200 ms – others on request
    Swich-on time < 1 s
    Temperature coefficient Zero: ≤ ± 0,015 % FS / Kelvin
    Span: ≤ ± 0,01 % FS / Kelvin
    Medium temperature -40…100 °C (125 °C < 0,5 h)
    -20…80 °C with EX ia IIC T4
    Surrounding temperature -25…80 °C
    -20…80 °C with EX ia IIC T4
    Storage temperature -40…85 °C
    Short-circuit resistance Permanent
    Reverse polarity protection Protection against reverse polarity, but no function
    Electromagnetic compatibility Interference emissions and immunity acc. to EN 61326
    Vibration 4g with 3-axis resonance frequency according to DIN EN 60068-2-6:2008
    Wetted materials Process connection: Stainless steel 1.4404
    Sensor: Ceramic Al2O– FDA
    Process seal: FPM (Viton), NBR, EPDM, FFKM (Chemraz / Kalrez)
    Protection type IP 65
    IP 67 with cable connection
    Weight Approx. 250 g