The Bipolar Isolation Amplifier DIS 64000 is used for isolation and conversion of bipolar and unipolar industrial standard signals.
- Calibrated signal setting via DIP switch
Input and output range can be set by using DIP switch – high precision without any further adjustment - High bandwidth; short response time
No signal distortion; no falsification of measured signal - Switchable Zero/Span compensation
For readjustment of the sensor or field device - 3-Port isolation
Protection against erroneous measurements due to parasitic voltages or ground loops - Extremely slim design
6.2 mm slim housing for a simple and space saving DIN rail mounting - Optional In-Rail-Bus mounting rail connector
allows for fast and economical installation - Protective Separation acc. to EN 61140
Protects service personnel and downstream devices against impermissibly high voltage - 5 Years Warranty
Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender)
The Bipolar Isolation Amplifier IS 64000 is used for isolation and conversion of bipolar and unipolar industrial standard signals.
The input and output range of IS 64000 can be easily set by using DIP switch. Due to the calibrated range selection no further adjustment is necessary.
A switchable compensation of the measuring range can be performed at the Zero/Span potentiometers on the front panel. Also the cut-off frequency can be adapted to the measurement task by using the DIP Switch.
The auxiliary power can be supplied via the connection terminals or via the optional In- Rail-Bus connector. A green LED on the front of the unit has been provided to monitor the power supply.
Input
Current | Voltage | |
Input signal (calibrated switchable) |
± 20 mA, 0 to 20 mA, 4 to 20 mA ± 10 mA, 0 to 10 mA, 2 to 10 mA |
± 10 V, 0 to 10 V, 2 to 10 V ± 5 V, 0 to 5 V, 1 to 5 V |
Input resistance | ≤ 25 Ohm | ≥ 1 MOhm |
Overload | < 50 mA | < 30 V |
Output
Current | Voltage | |
Output signal (calibrated switchable) |
± 20 mA, 0 to 20 mA, 4 to 20 mA ± 10 mA, 0 to 10 mA, 2 to 10 mA |
± 10 V, 0 to 10 V, 2 to 10 V ± 5 V, 0 to 5 V, 1 to 5 V |
Load | ≤ 12 V (600 Ohm at 20 mA) | ≤ 5 mA (2 kOhm at 10 V) |
Linear transmission range | unipolar: –1 to +110 %, bipolar: –110 to +110 % | |
Residual ripple | < 10 mVrms |
General Data
Transmission error | < 0.1 % full scale | ||||||||||
Temperature coefficient 1) | < 100 ppm/K | ||||||||||
Zero/Span compensation | ±5 % of measuring range, switchable | ||||||||||
Cut-off frequency -3 dB | 8 kHz, 100 Hz , switchable | ||||||||||
Response time T99 | 100 µs, 7 ms | ||||||||||
Test voltage | 3 kV AC, 50 Hz, 1 min, input against output against power supply | ||||||||||
Working voltage 2) (Basic Insulation) |
600 V AC/DC for overvoltage category II and pollution degree 2 acc. to EN 61010-1 | ||||||||||
Protection against electrical shock 2) | Protective separation according to EN 61140 by reinforced insulation in accordance with EN 61010-1 up to 300 V AC/DC for overvoltage category II and pollution degree 2 between all circuits. | ||||||||||
Ambient temperature | Operation Transport and storage |
–25 °C to +70 °C (-13 to +158 °F) –40 °C to +85 °C (-40 to +185 °F) |
|||||||||
Power supply | 24 V DC, voltage range 9.6 V to 31.2 V DC, approx. 0.8 W | ||||||||||
EMC 3) | EN 61326-1 | ||||||||||
Approvals |
|
||||||||||
Construction | 6.2 mm (0.244″) housing, protection class: IP 20 mounting on 35 mm DIN rail acc. to EN 60715 |
||||||||||
Weight | Approx. 70 g |