TP Basic / Dryblock-temperature calibrator Type TP17166


  • Temperature range -35…165 °C
  • Calibration insert dimensions: Ø60 x 150 mm
  • Accuracy ±0.4 °C
Datasheet
Datasheet
User Manual

  • Compact design for on-site use
  • simple calibration without consideration of viscosities, flash points or outgassing
  • large calibration volume for simultaneous calibration of several DUT
  • optimum thermal coupling from block to DUT due to SIKA calibration inserts

 

Whether for on-site use in the workshop, in the measuring and test room or laboratory, SIKA temperature calibrators can be used everywhere. A wide range of industries and various application areas are covered.

• assembly, commissioning

• manufacturing, production

• maintenance, service

• quality assurance, test equipment monitoring

• repair

Dry block function

The dry block function was developed to enable easy calibration of the temperature in lab and field applications. The optimum thermal coupling from block to DUT is achieved by the correct calibration insert. Ideally, the inner diameter of the bore hole in the calibration insert is 0.5 mm larger than the outer diameter of the DUT. With the help of the calibration insert almost all straight temperature sensors with different lengths and diameters can be calibrated. The dry block covers the entire temperature range without changing the calibration medium. The user does not have to take viscosities, flash points or outgassing into consideration.









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    TP Basic / Dryblock-temperature calibrator Type TP17166

    • Temperature range -35…165 °C
    • Calibration insert dimensions: Ø60 x 150 mm
    • Accuracy ±0.4 °C
    Datasheet
    Datasheet
    User Manual

    • Compact design for on-site use
    • simple calibration without consideration of viscosities, flash points or outgassing
    • large calibration volume for simultaneous calibration of several DUT
    • optimum thermal coupling from block to DUT due to SIKA calibration inserts

     

    Whether for on-site use in the workshop, in the measuring and test room or laboratory, SIKA temperature calibrators can be used everywhere. A wide range of industries and various application areas are covered.

    • assembly, commissioning

    • manufacturing, production

    • maintenance, service

    • quality assurance, test equipment monitoring

    • repair

    Dry block function

    The dry block function was developed to enable easy calibration of the temperature in lab and field applications. The optimum thermal coupling from block to DUT is achieved by the correct calibration insert. Ideally, the inner diameter of the bore hole in the calibration insert is 0.5 mm larger than the outer diameter of the DUT. With the help of the calibration insert almost all straight temperature sensors with different lengths and diameters can be calibrated. The dry block covers the entire temperature range without changing the calibration medium. The user does not have to take viscosities, flash points or outgassing into consideration.









    Technical advice: 03303 / 50 40 66

    Technical advice for this product