WIKA Type BSU-30 Calculation Unit with Multiple Sensor Inputs and Calculation Functions


  • Temperature- and pressure-compensated density (CD)
  • Calculation of gas concentrations in binary mixtures (% gas A / % gas B), specific gravity (SG) and molar mass (M)
  • Conversion into analog and digital formats
  • Calculated values available via 4 … 20 mA outputs or RS-485 Modbus®
  • Display of calculated values
Datasheet

Applications

  • Gas monitoring
  • Gas quality control
  • Determination of molar mass, specific gravity and binary gas concentrations
  • Management of density and temperature sensors (model DTG-30) and pressure sensors

 

Description

The BSU-30 is a calculation unit that combines various sensor inputs and calculates specific parameters. Thanks to its compact design, the BSU-30 is ideal for use in gas dosing systems.

The BSU-30 features two 4 … 20 mA analog inputs for connecting one or two pressure sensors (such as model IS-3 or S-20) and one RS-485 Modbus® input for connecting one or two density and temperature sensors (model DTG-30).

The BSU-30 can calculate secondary values such as average molar mass, specific gravity or gas concentration in binary mixtures from primary measurements (temperature, pressure and density).

In addition, the BSU-30 can provide the calculated values as well as the primary measurements to other systems such as PLCs, control systems or displays in analog or digital formats.







Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    WIKA Type BSU-30 Calculation Unit with Multiple Sensor Inputs and Calculation Functions

    • Temperature- and pressure-compensated density (CD)
    • Calculation of gas concentrations in binary mixtures (% gas A / % gas B), specific gravity (SG) and molar mass (M)
    • Conversion into analog and digital formats
    • Calculated values available via 4 … 20 mA outputs or RS-485 Modbus®
    • Display of calculated values
    Datasheet

    Applications

    • Gas monitoring
    • Gas quality control
    • Determination of molar mass, specific gravity and binary gas concentrations
    • Management of density and temperature sensors (model DTG-30) and pressure sensors

     

    Description

    The BSU-30 is a calculation unit that combines various sensor inputs and calculates specific parameters. Thanks to its compact design, the BSU-30 is ideal for use in gas dosing systems.

    The BSU-30 features two 4 … 20 mA analog inputs for connecting one or two pressure sensors (such as model IS-3 or S-20) and one RS-485 Modbus® input for connecting one or two density and temperature sensors (model DTG-30).

    The BSU-30 can calculate secondary values such as average molar mass, specific gravity or gas concentration in binary mixtures from primary measurements (temperature, pressure and density).

    In addition, the BSU-30 can provide the calculated values as well as the primary measurements to other systems such as PLCs, control systems or displays in analog or digital formats.