Portable density meter: DMA35Ex Petrol


  • For measuring petroleum samples in hazardous environments
  • The only intrinsically safe portable density meter on the market (Ex marking [Ex] II 2 G Ex ib IIB T4)
  • Fully complies with the ASTM D7777 and IP 559 standards
  • Protection class IP54

Datasheet
User Manual

Take DMA 35 with you at all times and measure the density and concentration of your sample directly on-site. One portable density meter replaces all the glass hydrometers in your workplace and gives you the accuracy expected from a lab instrument. DMA 35 uses only two milliliters of sample and saves you a lot of time as there is no need to transport the sample to the lab. It is built to withstand the knocks and spills of outdoor use. An RFID interface for quick sample identification and a Bluetooth® interface for convenient data handling in the field are integral parts of the instrument.

We’ve been making portable density meters since 1981, and have led the global market in density measurement for more than half a century.

 

A portable density meter providing accurate results, also under harsh conditions

The splash-proof DMA 35 is made for density and concentration measurement in harsh environments, including outdoor operation, while providing the accuracy expected from a lab instrument. The smart oscillator placement makes sure that gas bubbles move to where they can’t affect your result: outside the measuring cell.

Designed for on-site density measurements

Designed for on-site density measurements

  • Leak-proof sealed housing to withstand harsh conditions in industrial and field applications
  • Additional rubber protection keeps the measuring cell safe
  • Operation via capacitive keys so sensitive they can be used with gloves
  • Suitable for both left- and right-handed users
  • RFID tag readings, measurement start or abort, via gesture control: One hand is free to hold you steady with hard-to-reach samples.
  • For sample temperatures up to 100 °C, quick decision support, e. g. in the beer brewing process (measurement of hot wort)
  • Graphical visualization of the fermentation process for each fermentation tank
  • Smart patented oscillator connection (AT516421 B1, EP3015847 B1) permits replacement in case of cell rupture
Intrinsically safe – for use in hazardous locations

Intrinsically safe – for use in hazardous locations

  • Intrinsically safe models DMA 35 Ex and DMA 35 Ex Petrol (Ex marking [Ex] II 2 G Ex ib IIB T4) for use in hazardous areas
  • The only option available on the market for safe measurements in explosive atmospheres
  • DMA 35 Ex is particularly suitable for measuring flammable chemicals.
  • DMA 35 Ex Petrol provides excellent resistance to petroleum samples and fully complies with the ASTM D7777 and IP 559 standards.
Fastest filling and measurement – for a huge variety of samples

Fastest filling and measurement – for a huge variety of samples

  • Fill all kinds of samples – no matter what the viscosity is – in one second using the built-in manual pump or a syringe.
  • No expensive electrical wearing parts: You can easily do all cleaning and maintenance work yourself.
  • Measuring cell with inspection window and backlight for convenient inspection of proper sample filling
  • The most reliable portable density meter for fermenting beer or wine, due to intelligent oscillator placement (potential bubbles automatically move outside the measuring cell)
  • Lock-position of pump preventing sample carryover
  • Auto-rotating display for perfect visibility of results at any instrument position
  • Influence of viscosity on your density result is automatically corrected: for reliable measurements, also on highly viscous samples
Perfect traceability of density and concentration results

Perfect traceability of density and concentration results

  • Storage of up to 250 sample IDs for easy sample identification
  • RFID interface for changing measurement settings quickly by reading RFID tags
  • Storage of up to 1024 measurement results including time stamp and sample ID
  • Wireless data exchange with a PC (csv or txt format) and data export to a printer via Bluetooth® for convenient data handling in the field – no extra software required
Leave your glass hydrometer or pycnometer for a digital density meter

Leave your glass hydrometer or pycnometer for a digital density meter

  • Measurement directly at the sample container
  • Requires only 2 mL of sample, filled via the built-in pump
  • Preinstalled and programmable concentration units – no further calculations necessary
  • Results available in seconds
  • Perfect traceability of results

Calculate your individual savings now:

ROI calculator

Quickly determining the state of charge of lead-acid batteries

Technical specifications

Patents granted Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1), CN 105571982 B
Other special functions Viscosity correction for reliable measurements, also on highly viscous samples
Gesture control for easy one-handed measurements
Identification of results outside your specified limits
Measuring range Density: 0 g/cm³ to 3 g/cm³
Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
Accuracy Density: 0.001 g/cm³ **
Temperature: 0.2 °C (0.4 °F)
Repeatability, s.d.*** Density: 0.0005 g/cm³ **
Temperature: 0.1 °C (0.2 °F)
Reproducibility, s.d.*** Density: 0.0007 g/cm³
Digital Resolution Density: 0.0001 g/cm³
Temperature: 0.1 °C (0.1 °F)
Ambient temperature**** Standard Version, Ampere Version: -10 °C to +50 °C (14 °F to 122 °F)
Ex and Ex Petrol version: -10 °C to +40 °C (14 °F to 104 °F)
Supported measuring units
  • Specific gravity
  • Alcohol tables
  • Sugar/extract tables
  • API functions
  • H2SO4 tables
  • Ten programmable custom-specific measuring units
Sample volume 2 mL
Dimensions (L x W x H) 245 mm x 103 mm x 126 mm
Data memory 1024 measured results, 30 measuring methods, 250 sample IDs
Power supply Three 1.5 V LR06 AA alkaline batteries
Weight 660 g
Interfaces Bluetooth®, RFID (both included by default)
Protection class IP54
(first digit: 5 – protection against dust ingress; second digit: 4 – protection against splash water from any direction)
Intrinsic safety of Ex and Ex Petrol version ATEX: II 2G Ex ib IIB T4 Gb
IECEx: Ex ib IIB T4 Gb
Scope of supply Portable density meter, filling tube, adapter for syringe filling, syringes, transportation case, rubber protection for measuring cell, three batteries, Allen key, instructions
Menu language English, German, Chinese, Japanese, French, Russian, Italian, Portuguese, Turkish, Spanish
Available options

Elongated filling tube
Portable thermal printer with Bluetooth® interface
Bluetooth® USB adapter
Wristband
Carrying strap
ISO calibration

* Measurements up to 100 °C possible
** Viscosity <300 mPa•s, density <2 g/cm³
*** according to ISO 5725
**** Sample must not freeze within the measuring cell; Ex and Ex Petrol version: -10 °C to +40 °C (14 °F to 104 °F)

DMA is a registered trademark of Anton Paar (EM 013414867)









Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    Portable density meter: DMA35Ex Petrol

    • For measuring petroleum samples in hazardous environments
    • The only intrinsically safe portable density meter on the market (Ex marking [Ex] II 2 G Ex ib IIB T4)
    • Fully complies with the ASTM D7777 and IP 559 standards
    • Protection class IP54

    Datasheet
    User Manual

    Take DMA 35 with you at all times and measure the density and concentration of your sample directly on-site. One portable density meter replaces all the glass hydrometers in your workplace and gives you the accuracy expected from a lab instrument. DMA 35 uses only two milliliters of sample and saves you a lot of time as there is no need to transport the sample to the lab. It is built to withstand the knocks and spills of outdoor use. An RFID interface for quick sample identification and a Bluetooth® interface for convenient data handling in the field are integral parts of the instrument.

    We’ve been making portable density meters since 1981, and have led the global market in density measurement for more than half a century.

     

    A portable density meter providing accurate results, also under harsh conditions

    The splash-proof DMA 35 is made for density and concentration measurement in harsh environments, including outdoor operation, while providing the accuracy expected from a lab instrument. The smart oscillator placement makes sure that gas bubbles move to where they can’t affect your result: outside the measuring cell.

    Designed for on-site density measurements

    Designed for on-site density measurements

    • Leak-proof sealed housing to withstand harsh conditions in industrial and field applications
    • Additional rubber protection keeps the measuring cell safe
    • Operation via capacitive keys so sensitive they can be used with gloves
    • Suitable for both left- and right-handed users
    • RFID tag readings, measurement start or abort, via gesture control: One hand is free to hold you steady with hard-to-reach samples.
    • For sample temperatures up to 100 °C, quick decision support, e. g. in the beer brewing process (measurement of hot wort)
    • Graphical visualization of the fermentation process for each fermentation tank
    • Smart patented oscillator connection (AT516421 B1, EP3015847 B1) permits replacement in case of cell rupture
    Intrinsically safe – for use in hazardous locations

    Intrinsically safe – for use in hazardous locations

    • Intrinsically safe models DMA 35 Ex and DMA 35 Ex Petrol (Ex marking [Ex] II 2 G Ex ib IIB T4) for use in hazardous areas
    • The only option available on the market for safe measurements in explosive atmospheres
    • DMA 35 Ex is particularly suitable for measuring flammable chemicals.
    • DMA 35 Ex Petrol provides excellent resistance to petroleum samples and fully complies with the ASTM D7777 and IP 559 standards.
    Fastest filling and measurement – for a huge variety of samples

    Fastest filling and measurement – for a huge variety of samples

    • Fill all kinds of samples – no matter what the viscosity is – in one second using the built-in manual pump or a syringe.
    • No expensive electrical wearing parts: You can easily do all cleaning and maintenance work yourself.
    • Measuring cell with inspection window and backlight for convenient inspection of proper sample filling
    • The most reliable portable density meter for fermenting beer or wine, due to intelligent oscillator placement (potential bubbles automatically move outside the measuring cell)
    • Lock-position of pump preventing sample carryover
    • Auto-rotating display for perfect visibility of results at any instrument position
    • Influence of viscosity on your density result is automatically corrected: for reliable measurements, also on highly viscous samples
    Perfect traceability of density and concentration results

    Perfect traceability of density and concentration results

    • Storage of up to 250 sample IDs for easy sample identification
    • RFID interface for changing measurement settings quickly by reading RFID tags
    • Storage of up to 1024 measurement results including time stamp and sample ID
    • Wireless data exchange with a PC (csv or txt format) and data export to a printer via Bluetooth® for convenient data handling in the field – no extra software required
    Leave your glass hydrometer or pycnometer for a digital density meter

    Leave your glass hydrometer or pycnometer for a digital density meter

    • Measurement directly at the sample container
    • Requires only 2 mL of sample, filled via the built-in pump
    • Preinstalled and programmable concentration units – no further calculations necessary
    • Results available in seconds
    • Perfect traceability of results

    Calculate your individual savings now:

    ROI calculator

    Quickly determining the state of charge of lead-acid batteries

    Technical specifications

    Patents granted Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1), CN 105571982 B
    Other special functions Viscosity correction for reliable measurements, also on highly viscous samples
    Gesture control for easy one-handed measurements
    Identification of results outside your specified limits
    Measuring range Density: 0 g/cm³ to 3 g/cm³
    Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
    Accuracy Density: 0.001 g/cm³ **
    Temperature: 0.2 °C (0.4 °F)
    Repeatability, s.d.*** Density: 0.0005 g/cm³ **
    Temperature: 0.1 °C (0.2 °F)
    Reproducibility, s.d.*** Density: 0.0007 g/cm³
    Digital Resolution Density: 0.0001 g/cm³
    Temperature: 0.1 °C (0.1 °F)
    Ambient temperature**** Standard Version, Ampere Version: -10 °C to +50 °C (14 °F to 122 °F)
    Ex and Ex Petrol version: -10 °C to +40 °C (14 °F to 104 °F)
    Supported measuring units
    • Specific gravity
    • Alcohol tables
    • Sugar/extract tables
    • API functions
    • H2SO4 tables
    • Ten programmable custom-specific measuring units
    Sample volume 2 mL
    Dimensions (L x W x H) 245 mm x 103 mm x 126 mm
    Data memory 1024 measured results, 30 measuring methods, 250 sample IDs
    Power supply Three 1.5 V LR06 AA alkaline batteries
    Weight 660 g
    Interfaces Bluetooth®, RFID (both included by default)
    Protection class IP54
    (first digit: 5 – protection against dust ingress; second digit: 4 – protection against splash water from any direction)
    Intrinsic safety of Ex and Ex Petrol version ATEX: II 2G Ex ib IIB T4 Gb
    IECEx: Ex ib IIB T4 Gb
    Scope of supply Portable density meter, filling tube, adapter for syringe filling, syringes, transportation case, rubber protection for measuring cell, three batteries, Allen key, instructions
    Menu language English, German, Chinese, Japanese, French, Russian, Italian, Portuguese, Turkish, Spanish
    Available options

    Elongated filling tube
    Portable thermal printer with Bluetooth® interface
    Bluetooth® USB adapter
    Wristband
    Carrying strap
    ISO calibration

    * Measurements up to 100 °C possible
    ** Viscosity <300 mPa•s, density <2 g/cm³
    *** according to ISO 5725
    **** Sample must not freeze within the measuring cell; Ex and Ex Petrol version: -10 °C to +40 °C (14 °F to 104 °F)

    DMA is a registered trademark of Anton Paar (EM 013414867)









    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.