DMA4501 Benchtop density meter


  • 5-digit accuracy in 30 seconds
  • The industry-proven device for QC for a wide range of samples
  • Eight additional parameters and seven sample changers available
  • Five industry-specific user profiles
  • 30+ guided workflows support your measurements
Datasheet
User Manual

We’ve incorporated over five decades of experience developing market-leading benchtop density meters into our new generation of density meters. With best-in-class U-tube technology based on our patented Pulsed Excitation Method, our Next-Level Density Meters are the fastest, most intelligent benchtop density meters we’ve made to date.
20-second (4-digit) results give you high throughput. Compliance with a range of standards gives you peace of mind. There’s storage space for up to 10,000 measurements. And up to 6-digit accuracy gives you results you can rely on.
Now that’s taking it to the next level.

Key features

Fast and accurate benchtop density meters

Fast and accurate benchtop density meters

  • Get market-leading precision, repeatability, and reproducibility with our patented Pulsed Excitation Method
  • Maximize throughput with an ultra-fast measurement mode
  • Define limits for different samples and make pass/fail QC decisions right away
  • 200+ pre-installed conversion tables show concentration values immediately
  • Achieve excellent results for highly viscous samples with the best viscosity correction on the market
  • Get reliable measurement results for high- and low-density samples as well as inhomogeneous, sedimenting, or particle-containing ones
High-tech features simplify your lab

High-tech features simplify your lab

  • Know your samples are filled correctly with FillingCheck™, which even detects microbubbles, and U-ViewTM, which shows a zoomable image of the measuring cell
  • Benefit from an automatic compensation of the U-tube’s aging effects and minimized drift over the lifetime of the instrument
  • Use 30+ guided user workflows and five industry-specific profiles with predefined quantities and scales
  • Streamline your data management with AP Connect
Guaranteed compliance gives you peace of mind

Guaranteed compliance gives you peace of mind

  • Comply with ASTM D4052, D5002, D1250, ISO 12185 petroleum standards, and all relevant pharmacopeias
  • Satisfy all major data integrity and traceability standards (e.g., 21 CFR Part 11)
  • Ensure your results are traceable to the International System of Units (SI) with ISO 17025 calibration from our accredited lab
  • Use our ISO 17034-certified reference material for density to ensure your instrument is perfectly calibrated
Modularity lets you conduct multiparameter analysis

Modularity lets you conduct multiparameter analysis

  • Connect your benchtop density meter to a range of Anton Paar measuring modules to forge a multiparameter system
  • Measure all relevant QC parameters from the same sample under the same conditions
  • Measure more than eight parameters at once
Automated processes for higher throughput

Automated processes for higher throughput

  • Automate your filling, measuring, and cleaning process by choosing from seven different sample changers (optional)
  • Ensure accurate results without operator influence
  • Reduce contact with dangerous substances during filling with automated sample changers

Technical specifications

DMA 4101 DMA 4501 DMA 5001
Measuring range
Density 0 g/cm³ to 3 g/cm³
Temperature 0 °C to 100 °C (32 °F to 212 °F)
Pressure Up to 10 bar (145 psi) absolute pressure
Accuracy
Density 0.0001 g/cm³ 0.00005 g/cm³ (full range)
0.00001 g/cm³ (0 g/cm³ to 1 g/cm³, 15 °C to 20 °C)
0.000005 g/cm³
Temperature 0.03 °C (0.05 °F) 0.02 °C (0.04 °F) (full range)
0.01 °C (0.02 °F) (15 °C to 20 °C)
0.01 °C (0.02 °F)
Repeatability
Density 0.00001 g/cm³ 0.000005 g/cm³ 0.000001 g/cm³
Temperature 0.02 °C (0.04 °F) 0.01 °C (0.02 °F) 0.001 °C (0.002 °F)
Reproducibility
Density 0.00005 g/cm³ 0.00002 g/cm³ 0.000005 g/cm³
Digital resolution
Density 0.0001 g/cm³ 0.00001 g/cm³ 0.000001 g/cm³
Features
Power features U-View™, FillingCheck™, ThermoBalance™, full-range viscosity correction
Special functions QM compliance, temperature scan, built-in ambient pressure sensor, condition monitoring adjustment at high viscosity (only DMA 5001 )
Automation Automatic sample changers
Modularity pH, alcohol, CO2, O2, color, turbidity, refractive index
Optional accessories Aerosol adapter, heating attachment
Technical data
Typical measuring time/sample 20 s 30 s 40 s
Minimum sample volume Approx. 1 mL
Wetted materials PTFE, borosilicate glass
Dimensions (L x W x H) 526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in)
Weight 22.04 kg (48.6 lbs)
Power supply AC 100 to 240 V, 50/60 Hz, fluctuation ±10 %, 190 VA
Display 10.1″ TFT WXGA (1280 x 800 px); PCAP touchscreen
Controls Touchscreen, optional keyboard, mouse, and barcode reader
Communication interfaces 5 x USB, Ethernet, CAN, RS232
Internal storage More than 10,000 measuring values with camera images








Technical advice: 03303 / 50 40 66

Technical advice for this product


    In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



    DMA4501 Benchtop density meter

    • 5-digit accuracy in 30 seconds
    • The industry-proven device for QC for a wide range of samples
    • Eight additional parameters and seven sample changers available
    • Five industry-specific user profiles
    • 30+ guided workflows support your measurements
    Datasheet
    User Manual

    We’ve incorporated over five decades of experience developing market-leading benchtop density meters into our new generation of density meters. With best-in-class U-tube technology based on our patented Pulsed Excitation Method, our Next-Level Density Meters are the fastest, most intelligent benchtop density meters we’ve made to date.
    20-second (4-digit) results give you high throughput. Compliance with a range of standards gives you peace of mind. There’s storage space for up to 10,000 measurements. And up to 6-digit accuracy gives you results you can rely on.
    Now that’s taking it to the next level.

    Key features

    Fast and accurate benchtop density meters

    Fast and accurate benchtop density meters

    • Get market-leading precision, repeatability, and reproducibility with our patented Pulsed Excitation Method
    • Maximize throughput with an ultra-fast measurement mode
    • Define limits for different samples and make pass/fail QC decisions right away
    • 200+ pre-installed conversion tables show concentration values immediately
    • Achieve excellent results for highly viscous samples with the best viscosity correction on the market
    • Get reliable measurement results for high- and low-density samples as well as inhomogeneous, sedimenting, or particle-containing ones
    High-tech features simplify your lab

    High-tech features simplify your lab

    • Know your samples are filled correctly with FillingCheck™, which even detects microbubbles, and U-ViewTM, which shows a zoomable image of the measuring cell
    • Benefit from an automatic compensation of the U-tube’s aging effects and minimized drift over the lifetime of the instrument
    • Use 30+ guided user workflows and five industry-specific profiles with predefined quantities and scales
    • Streamline your data management with AP Connect
    Guaranteed compliance gives you peace of mind

    Guaranteed compliance gives you peace of mind

    • Comply with ASTM D4052, D5002, D1250, ISO 12185 petroleum standards, and all relevant pharmacopeias
    • Satisfy all major data integrity and traceability standards (e.g., 21 CFR Part 11)
    • Ensure your results are traceable to the International System of Units (SI) with ISO 17025 calibration from our accredited lab
    • Use our ISO 17034-certified reference material for density to ensure your instrument is perfectly calibrated
    Modularity lets you conduct multiparameter analysis

    Modularity lets you conduct multiparameter analysis

    • Connect your benchtop density meter to a range of Anton Paar measuring modules to forge a multiparameter system
    • Measure all relevant QC parameters from the same sample under the same conditions
    • Measure more than eight parameters at once
    Automated processes for higher throughput

    Automated processes for higher throughput

    • Automate your filling, measuring, and cleaning process by choosing from seven different sample changers (optional)
    • Ensure accurate results without operator influence
    • Reduce contact with dangerous substances during filling with automated sample changers

    Technical specifications

    DMA 4101 DMA 4501 DMA 5001
    Measuring range
    Density 0 g/cm³ to 3 g/cm³
    Temperature 0 °C to 100 °C (32 °F to 212 °F)
    Pressure Up to 10 bar (145 psi) absolute pressure
    Accuracy
    Density 0.0001 g/cm³ 0.00005 g/cm³ (full range)
    0.00001 g/cm³ (0 g/cm³ to 1 g/cm³, 15 °C to 20 °C)
    0.000005 g/cm³
    Temperature 0.03 °C (0.05 °F) 0.02 °C (0.04 °F) (full range)
    0.01 °C (0.02 °F) (15 °C to 20 °C)
    0.01 °C (0.02 °F)
    Repeatability
    Density 0.00001 g/cm³ 0.000005 g/cm³ 0.000001 g/cm³
    Temperature 0.02 °C (0.04 °F) 0.01 °C (0.02 °F) 0.001 °C (0.002 °F)
    Reproducibility
    Density 0.00005 g/cm³ 0.00002 g/cm³ 0.000005 g/cm³
    Digital resolution
    Density 0.0001 g/cm³ 0.00001 g/cm³ 0.000001 g/cm³
    Features
    Power features U-View™, FillingCheck™, ThermoBalance™, full-range viscosity correction
    Special functions QM compliance, temperature scan, built-in ambient pressure sensor, condition monitoring adjustment at high viscosity (only DMA 5001 )
    Automation Automatic sample changers
    Modularity pH, alcohol, CO2, O2, color, turbidity, refractive index
    Optional accessories Aerosol adapter, heating attachment
    Technical data
    Typical measuring time/sample 20 s 30 s 40 s
    Minimum sample volume Approx. 1 mL
    Wetted materials PTFE, borosilicate glass
    Dimensions (L x W x H) 526 mm x 347 mm x 230 mm (20.7 in x 13.7 in x 9 in)
    Weight 22.04 kg (48.6 lbs)
    Power supply AC 100 to 240 V, 50/60 Hz, fluctuation ±10 %, 190 VA
    Display 10.1″ TFT WXGA (1280 x 800 px); PCAP touchscreen
    Controls Touchscreen, optional keyboard, mouse, and barcode reader
    Communication interfaces 5 x USB, Ethernet, CAN, RS232
    Internal storage More than 10,000 measuring values with camera images








    Technical advice: 03303 / 50 40 66

    Technical advice for this product


      In accordance with the General Data Protection Regulation (GDPR), we are obliged to inform you about the collection of data. We meet this obligation by referring to our privacy notice.



      Diese Website benutzt Cookies. Wenn du die Website weiter nutzt, gehen wir von deinem Einverständnis aus.