Dynisco DYN-X Series
The Dynisco DYN-X Series includes economical melt pressure sensors for general pressure measurement tasks in plastics processing. The sensors are designed for applications requiring simple installation, reliable measurements and good repeatability. As a value-priced series, the DYN-X provides an industry-standard 3.33 mV/V output signal and is designed to work with most common pressure indicators and readout instruments.
The DYN-X pressure sensors offer an accuracy of ±1.0 % FSO combined error, including linearity, repeatability and hysteresis. The standard wetted parts are made of DyMax® coated 15-5 PH stainless steel. This supports superior abrasion resistance and contributes to stable and repeatable pressure measurements.
The series is available for pressure ranges from 0…500 psi to 0…10,000 psi. The sensors feature a four-arm bonded foil Wheatstone bridge strain gauge, internal 80 % shunt calibration and a 1/2-20 UNF process thread for installation in standard transducer mounting holes. Optional thermocouple or RTD configurations are available to provide melt temperature measurement in addition to pressure measurement.
| Type | Melt pressure sensor for general industrial applications |
|---|---|
| Series | Dynisco DYN-X Series |
| Application | General melt pressure measurement in plastics processing, extrusion and industrial processes |
| Output signal | 3.33 mV/V ±2.0 % |
| Input voltage | 10 VDC recommended, 12 VDC maximum |
| Pressure ranges | 0…500 psi to 0…10,000 psi |
| Accuracy | ±1.0 % FSO combined error, including linearity, repeatability and hysteresis |
| Repeatability | ±0.2 % FSO |
| Over pressure | 2 × FSO |
| Configuration | Four-arm bonded foil Wheatstone bridge strain gauge |
| Bridge resistance | Input and output: 345 Ω minimum |
| Zero balance | ±10 % FSO |
| Internal shunt calibration | 80 % FSO ±1 % |
| Insulation resistance | 1000 MΩ at 50 VDC |
| Maximum diaphragm temperature | 750 °F / 400 °C |
| Zero shift due to diaphragm temperature change | 25 psi / 100 °F typical or 45 psi / 100 °C |
| Maximum electronics housing temperature | 250 °F / 121 °C |
| Zero shift due to electronics housing temperature change | ±0.05 % FS / °F max. or ±0.10 % FS / °C max. |
| Sensitivity shift due to temperature change | ±0.02 % FS / °F max. or ±0.04 % FS / °C max. |
| Mounting torque | 500 inch/lbs maximum |
| Standard wetted parts | DyMax® coated 15-5 PH stainless steel |
| Process connection | 1/2-20 UNF thread |
| Optional temperature measurement | Optional thermocouple or RTD configurations available to provide melt temperature measurement |
| Key features | Value-priced design, economical pressure measurement, good repeatability, DyMax® coated wetted parts, internal 80 % shunt calibration |